Products

LBMH4028 Series
40mm x 40mm x 28mm
DC Axial Fan

LBMH4028 Series 40mm x 40mm x 28mm DC Axial Fan

The LBMH4028 Series is a family of 40 mm × 40 mm × 28 mm DC axial fans designed for applications where a thicker profile is acceptable in exchange for substantially higher static pressure and airflow than standard 40 mm fans can provide. Its 28 mm depth positions it as a high-output alternative for thermal challenges that a 10 mm or 20 mm fan cannot overcome.

Design and bearing system. The series is built around a ball bearing construction, a choice that favors durability and consistent performance over extended service life compared with sleeve-bearing alternatives. Frame and impeller materials are plastic, keeping weight to approximately 40 g per unit. The available feature set across the series is notably rich: many variants carry PWM speed control, tachometer output, auto-restart, and thermal overload protection (TOP), while select models add Parylene coating for enhanced environmental resilience. These options allow the fan to be integrated into closed-loop thermal control architectures rather than simply run at full speed.

Performance envelope. The series spans 12 VDC and 24 VDC nominal inputs, with speeds ranging from 8,000 RPM at the low end to 18,000 RPM in high-output configurations. Airflow covers approximately 11.4 to 27.9 CFM (0.32–0.79 m³/min) , and static pressure reaches as high as 330 Pa (1.325 in H₂O) on the most aggressive 12 V model. Noise scales accordingly, from roughly 38 dBA in low-speed variants to the low 60s dBA at maximum output. A mid-range 24 V example delivers 21.1 CFM at 219.2 Pa and 52 dBA, illustrating the balance the series strikes between pressure head and acoustic cost.

Applications. The 4028 form factor is widely used in 1U/2U server cooling, networking hardware, battery thermal management for energy-storage systems, and compact industrial enclosures where depth is less constrained than face area. The higher static pressure capability makes it particularly effective when pushing air through dense heatsink fins or across tightly packed components, a role poorly served by thinner 40 mm fans.

In short, the LBMH4028 Series trades footprint depth for thermal authority. It is the appropriate selection when a 40 mm mounting pattern is fixed but the cooling demand exceeds what a slim profile can deliver.

LBM5210 Series
52mm x 52mm x 10mm
DC Axial Fan

LBM5210 Series 52mm x 52mm x 10mm DC Axial Fan

The LBM5210 Series is a line of 52 mm × 52 mm × 10 mm DC axial fans engineered for space-constrained thermal management where conventional fans cannot fit. This compact footprint delivers a balance of airflow and static pressure, making it suitable for dense electronics, networking equipment, and portable enclosures.

Design and Construction. The impeller and frame are molded from UL94V-0 rated PBT, offering flame retardancy and dimensional stability in demanding environments. The series typically offers a choice of ball bearing or sleeve bearing systems, allowing designers to prioritize either longer service life or cost efficiency. Standard lead wires are AWG 26 UL1007, and impedance protection is commonly included to safeguard the motor against current anomalies. Some variants also provide an optional tachometer output signal for speed monitoring.

Performance Range. The series supports 5 VDC and 12 VDC nominal inputs, with operating voltage windows that accommodate supply fluctuations. Depending on the model, speeds range from 4,000 RPM to 6,000 RPM, producing airflow of approximately 0.22 to 0.32 m³/min (8–11.3 CFM) and static pressure up to 3.7 mm H₂O (0.15 in H₂O) . Noise levels remain in the 24–36 dB(A) range, a practical envelope for noise-sensitive equipment. At the high-output end, the fan delivers 11.3 CFM at 6,000 RPM while consuming roughly 1.4–1.7 W, depending on the winding and bearing configuration.

Applications. The 52 mm square format is widely adopted in 1U/2U rack servers, network switches, power supplies, medical instruments, and industrial control cabinets. Its shallow 10 mm depth allows integration into low-profile chassis without sacrificing cooling headroom. The combination of a ribbed frame, polarity protection, and auto-restart functionality supports reliable continuous operation in commercial and industrial settings.

In summary, the LBM5210 Series addresses the persistent engineering challenge of fitting meaningful forced convection into minimal volume. It offers a pragmatic thermal solution for compact, high-density systems that demand dependable airflow without excessive acoustic penalty.

LBBE3G280-138NT-03 EC Medium Pressure Fan

LBBE3G280-138NT-03 EC Medium Pressure Fan

LBBE3G280-138NT-03 EC medium-pressure backward curved centrifugal fan, aluminum impeller, IP44, 3028m³/h at 860W, 73-85dB for factory heat dissipation.

LBBE3G280-102PS-07 EC Heat Dissipation Fan

LBBE3G280-102PS-07 EC Heat Dissipation Fan

LBBE3G280-102PS-07 EC backward curved centrifugal fan, aluminum alloy impeller, IP55/54/44 seal, 3193m³/h at 500W for factory heat dissipation.

LBBE3G280-102NS-06 EC Ventilation Centrifugal Fan

LBBE3G280-102NS-06 EC Ventilation Centrifugal Fan

LBBE3G280-102NS-06 EC backward curved centrifugal fan, aluminum alloy impeller, IP55 seal, 3863m³/h at 700W for factory ventilation and exhaust.

LBBE3G280-092PS-15 EC Heat Dissipation Fan

LBBE3G280-092PS-15 EC Heat Dissipation Fan

LBBE3G280-092PS-15 EC backward curved centrifugal fan, galvanized/aluminum impeller, IP44 seal, 1813m³/h at 165W for factory heat dissipation.

LBBE3G280-092NS-12 EC Backward Centrifugal Fan

LBBE3G280-092NS-12 EC Backward Centrifugal Fan

LBBE3G280-092NS-12 external rotor EC backward curved centrifugal fan, galvanized impeller, IP54/IP44, 1813m³/h at 165W, speed adjustable for factory ventilation.

LBBE3G280-072PS-01 EC Turbine Centrifugal Fan

LBBE3G280-072PS-01 EC Turbine Centrifugal Fan

LBBE3G280-072PS-01 low-noise EC backward curved centrifugal turbine fan, 2318m³/h at 170W, large airflow for fresh air systems and exhaust ventilation.

LBBE3G270-092NS-02 EC FFU Centrifugal Fan

LBBE3G270-092NS-02 EC FFU Centrifugal Fan

LBBE3G270-092NS-02 EC backward curved centrifugal fan, aluminum alloy impeller, IP44 seal, 1545m³/h at 150W for FFU filter units and cleanrooms.

LBMB6010 Series
60mm x 60mm x 10mm
DC Axial Fan

LBMB6010 Series 60mm x 60mm x 10mm DC Axial Fan

LOBISONG LBMB6010 Series — 60×60×10 mm DC Axial Fan

The LBMB6010 Series is LOBISONG’s 10 mm-ultrathin 60 mm square DC axial fan, the slimmest profile in the company’s 60 mm lineup. Public datasheets specific to the LBMB6010 designation are not readily available, so the performance envelope below reflects the broader 6010-class architecture this series belongs to rather than a single locked specification table.

Across the 6010 class, 5 V, 12 V, and 24 VDC inputs are standard, with speed options typically spanning 2,700 to 5,300 RPM. Airflow ranges from roughly 9.3 CFM on the lowest-speed variants to 18.7 CFM at the high end, while maximum static pressure scales from about 1.0 mmH₂O to 3.3 mmH₂O depending on the speed grade. Noise output tracks that progression from 19 dBA on quiet low-speed models up to 35 dBA at maximum RPM. Bearing choices include sleeve (lower cost, shorter service life) and ball bearing (extended life, better heat tolerance), and the frame and impeller are molded from UL94V-0 PBT for flame resistance. Unit weight is approximately 26 g.

Control and protection options follow LOBISONG’s standard 60 mm feature set: FG tachometer output, RD locked-rotor alarm, PWM speed control, reverse-polarity protection, and auto-restart. Operating temperature typically spans −10°C to +70°C, with storage tolerance down to −40°C.

The 10 mm depth makes the LBMB6010 the only viable choice when even a 15 mm or 20 mm fan will not clear the enclosure. Typical applications include 1U and blade-server slots, ultra-slim power supplies, credit-card-sized embedded boards, portable medical instruments, and dense portable electronics where height is the binding constraint and moderate airflow at low static pressure is sufficient.

LBG6015 Series
60mm x 60mm x 15mm
DC Axial Fan

LBG6015 Series 60mm x 60mm x 15mm DC Axial Fan

Mechatronics G6015 Series — 60×60×15 mm DC Axial Fan

The G6015 Series is Mechatronics’ 15 mm-thin 60 mm square DC axial fan, the slimmest profile in the 60 mm class and the go-to choice when board-to-enclosure clearance rules out a 20 mm or 25 mm frame. The series is organized as a six-tier speed matrix—G6015S, L, M, H, E, and X—so designers can pick the exact operating point rather than accept a single one-size compromise.

Across the range, speed spans 2,800 to 5,800 RPM, airflow climbs from approximately 11.0 to 24.0 CFM, and maximum static pressure rises from 0.32 to 0.68 mmH₂O. Noise tracks that progression from 21 dBA on the quiet S-tier to 35 dBA at the X-tier maximum. Nominal inputs cover 5, 12, and 24 VDC, with current draw scaling from 90 mA on low-speed variants to roughly 350 mA at the high end.

Construction uses a UL94V-0 PBT frame and impeller, ball bearings for extended service life, and a ribbed frame for structural rigidity. Standard protection includes reverse polarity and locked-rotor safeguards, while available options add tachometer output, locked-rotor alarm, PWM speed control, and encapsulated motors for dust- and moisture-prone environments. Select models carry an IP57 rating for washdown-adjacent or outdoor-adjacent installations.

With its 15 mm depth, the G6015 Series suits 1U rack equipment, slim power supplies, compact networking devices, embedded computing boards, and portable instrumentation—applications where every millimeter of height matters and moderate airflow at low-to-moderate static pressure is sufficient.

LBMD6020 Series
60mm x 60mm x 20mm
DC Axial Fan

LBMD6020 Series 60mm x 60mm x 20mm DC Axial Fan

LOBISONG LBMD6020 Series — 60×60×20 mm DC Axial Fan

The LBMD6020 Series is LOBISONG’s 20 mm-thin 60 mm DC axial fan, the slimmest profile in the company’s 60 mm square lineup. Public datasheets specific to the LBMD6020 designation are not readily available, so the performance envelope below reflects the broader 6020-class architecture this series belongs to rather than a single locked specification table.

Across the 6020 class, 5 V, 12 V, and 24 VDC inputs are standard, with speed options typically spanning 3,000 to 5,300 RPM. Airflow ranges from roughly 13 CFM to 29 CFM, and static pressure scales from about 2.0 mmH₂O on low-speed variants to 7.0 mmH₂O at the high end. Noise output tracks that progression from the mid-20s dBA on quiet low-speed models up to the low-40s dBA at maximum RPM. Bearing choices include sleeve (shorter service life, lower cost) and ball bearing (extended life, better heat tolerance), and the frame and impeller are molded from UL94V-0 PBT for flame resistance.

Control and protection options follow LOBISONG’s standard 60 mm feature set: FG tachometer output, RD locked-rotor alarm, PWM speed control, polarity protection, and auto-restart. Operating temperature typically spans −10°C to +70°C.

The 20 mm depth makes the LBMD6020 the choice when vertical clearance is the binding constraint and a 25 mm fan will not fit. Typical applications include slim power supplies, 1U/2U rack equipment, compact networking devices, portable instruments, and dense PCB enclosures where every millimeter of height matters and moderate static pressure is sufficient.

LBF6025 Series
60mm x 60mm x 25mm
DC Axial Fan

LBF6025 Series 60mm x 60mm x 25mm DC Axial Fan

LOBISONG LBF6025 Series — 60×60×25 mm DC Axial Fan

The LBF6025 Series is a 60 mm square DC axial fan with a 25 mm frame depth, sharing the compact footprint of the LBH and LBMR lines but tuned for a different balance of airflow and pressure. Public datasheets specific to the LBF6025 designation are limited, so the performance envelope below reflects the broader 6025-class architecture that this series belongs to rather than a single locked specification table.

Across the 6025 class, 12 VDC and 24 VDC inputs are standard, with 5 V and 48 V variants appearing in some catalogs. Speed options commonly span 2,500 to 4,600 RPM, producing airflow from roughly 13 CFM to 26 CFM and static pressure from about 1.15 mmH₂O to 6.16 mmAq depending on the selected speed grade. Noise output tracks that range from the low-20s dBA on quiet low-speed models up to the mid-30s dBA at the high end. Bearing choices include sleeve (≈30,000 h) and ball bearing (≈50,000 h at 40°C), and the frame and impeller are molded from UL94V-0 PBT.

Control and protection options include FG tachometer, RD alarm, PWM speed control, auto-restart, and polarity protection, matching the feature set expected across LOBISONG’s 60 mm families. Typical applications include compact power supplies, networking equipment, control cabinets, and general-purpose enclosure cooling where a 25 mm profile and moderate static pressure are sufficient.

LbMR6025 Series
60mm x 60mm x 25mm
DC Axial Fan

LbMR6025 Series 60mm x 60mm x 25mm DC Axial Fan

LOBISONG LBMR6025 Series — 60×60×25 mm DC Axial Fan

The LBMR6025 Series is LOBISONG's standard-profile 60 mm DC axial fan, using a 25 mm frame that fits applications where the deeper 38 mm class is not viable. The series is built around a broad speed matrix rather than a single operating point: depending on the selected model, airflow spans approximately 17.1 to 39.0 CFM, speed ranges from 3,500 to 8,000 RPM, and noise output scales from 31 dBA at the quiet end to 51 dBA at maximum performance.

Electrical options center on 12 VDC and 24 VDC nominal inputs, with current draw rising from roughly 0.05–0.09 A on low-speed variants to 0.18–0.36 A on the highest-speed models. Maximum static pressure follows the same progression, from approximately 3.56 mmH₂O at 3,500 RPM up to 18.54 mmH₂O at 8,000 RPM. Bearing construction is available in sleeve or ball bearing configurations, and the frame and impeller are molded from UL94V-0 PBT plastic for flame resistance.

For system-level control, the LBMR6025 supports FG tachometer output, RD locked-rotor alarm, and PWM speed control, alongside auto-restart and polarity protection as standard motor safeguards. Operating temperature is rated from −10°C to +70°C, with storage tolerance down to −40°C.

Typical applications include compact power supplies, telecom and networking equipment, industrial control panels, instrument enclosures, and stage-lighting or engraving equipment—installations that need a slim 60 mm fan with enough head pressure to push air through moderately dense internal layouts without resorting to a thicker, noisier high-static-pressure design.

LBH6025 Series
60mm x 60mm x 25mm
DC Axial Fan

LBH6025 Series 60mm x 60mm x 25mm DC Axial Fan

LOBISONG LBH6025 Series — 60×60×25 mm DC Axial Fan

The LBH6025 Series is a 60 mm square DC axial fan with a 25 mm frame depth, positioned as a balanced thermal solution for enclosures where a 38 mm-thick fan would exceed the available clearance. The series spans a broad performance envelope: depending on voltage and speed variant, it delivers airflow in the range of approximately 17 to 54 CFM, static pressure up to around 26 mmH₂O, and speed options from 3,000 RPM up to 10,000 RPM at the high end. Noise output correspondingly ranges from the high-20s dBA for low-speed quiet variants up to the mid-50s dBA at maximum performance.

The series accommodates 5 V, 12 V, 24 V, and 48 VDC nominal inputs, with power draw scaling from under 1 W at the low-speed end to several watts at maximum RPM. Bearing options typically include sleeve, hydraulic sleeve, and dual ball bearing, with ball-bearing construction supporting an expected life of up to 70,000 hours under favorable conditions. Frame and impeller are molded from UL94V-0 thermoplastic PBT, and optional functions include FG tachometer, RD alarm, PWM control, and locked-rotor protection.

With its slim 25 mm profile and wide voltage/speed matrix, the LBH6025 Series suits compact power supplies, telecom and networking equipment, inverter and UPS cooling, medical devices, and space-restricted control cabinets—applications that need reliable axial airflow without the depth penalty of a high-static-pressure fan.

LBMS6038 Series
60mm x 60mm x 38mm
DC Axial Fan

LBMS6038 Series 60mm x 60mm x 38mm DC Axial Fan

LBMS6038 Series — 60×60×38 mm DC Axial Fan

The LBMS6038 Series is a high-static-pressure DC axial fan engineered for space-constrained thermal management where airflow alone is insufficient. Its 38 mm depth enables a more aggressive impeller than standard 25 mm-thick 60 mm fans, generating static pressures up to 398.6 Pa (1.60 in H₂O) while delivering 31–58 CFM across the speed range of 6,000–11,000 RPM.

The series supports 12, 24, and 48 VDC inputs, with power consumption scaling from approximately 3.2 W at the low-speed end to 16.2 W at maximum performance. Noise output spans 39–59 dBA, allowing designers to select a low-noise variant for sensitive enclosures or a high-RPM variant when cooling margin is critical.

For system integration, the fan offers PWM speed control, tachometer (FG) output, and locked-rotor alarm options, alongside IP68 protection and conformal coating for harsh environments. The frame and impeller are constructed from UL94V-0 PBT plastic, with ball-bearing construction for long service life.

Typical applications include server and telecom rectifier cooling, industrial control cabinets, automotive electronics, CCTV systems, and compact power supplies where a 60 mm footprint must move meaningful air against dense component arrays. The LBMS6038 Series bridges the gap between compact size and serious thermal performance.

LBBE3G250-102PS-06 EC Turbine Centrifugal Fan

LBBE3G250-102PS-06 EC Turbine Centrifugal Fan

LBBE3G250-102PS-06 EC backward curved centrifugal turbine fan, aluminum alloy impeller, IP55/IP44, 2472m³/h at 520W for workshop exhaust.

LBBE3G250-092NS-22 EC Purifier Centrifugal Fan

LBBE3G250-092NS-22 EC Purifier Centrifugal Fan

250mm EC backward curved centrifugal fan with aluminum alloy impeller, IP44 sealed, 1730m³/h at 145W for air purifiers and factory air purification systems.