lbbe3g270-092ns-02-ec-ffu-centrifugal-fan, lbbe3g270-092ns-02-ec-ffu-centrifugal-fan, /ec-high-efficiency-fan
Inquiry
Inquiry

LBBE3G270-092NS-02 EC FFU Centrifugal Fan

LBBE3G270-092NS-02 EC backward curved centrifugal fan, aluminum alloy impeller, IP44 seal, 1545m³/h at 150W for FFU filter units and cleanrooms.

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G270-092NS-02 is a 270mm EC backward curved centrifugal fan designed for FFU filter unit assemblies and cleanroom ventilation. Built with an aluminum alloy impeller and a brushless EC motor, this backward curved centrifugal fan delivers 1545 m³/h at 1900 r/min on 150W shaft power, generating steady static pressure to hold airflow through HEPA and pre-filter media without running at excessive tip speed. The assembly is sealed to IP44, insulated to Class F, wired for 230V/115V 50/60Hz, and rated S1 continuous duty from -25℃ to +60℃. This model sits alongside a companion variant, the LWBE3G270-092NU-01, in the same 270mm family; both share the aluminum alloy impeller, ball bearing platform and 2 kg frame, while this backward curved centrifugal fan is the specified 150W unit for FFU and factory cleanroom air delivery.

Model Power Speed Air Flow
LBBE3G270-092NS-02 150W 1900 r/min 1545m³/h

Product Advantages

1. Aluminum Alloy Impeller for Filter Resistance

The core of this backward curved centrifugal fan is a 270mm aluminum alloy impeller with a backward-inclined blade path shaped for the pressure drop of real filter stacks. A backward curved centrifugal fan converts rotational speed into static pressure rather than free velocity, so it keeps 1545 m³/h flowing after air crosses a pre-filter and a HEPA panel instead of stalling as media loads. That pressure stability is the main reason this backward curved centrifugal fan is selected for FFU modules rather than free-delivery axial blowers. The metal rotor resists abrasive dust in factory airstreams and holds its blade geometry under heat, and its rotating mass damps vibration at the impeller hub, keeping noise and structure-borne vibration low in rooms occupied below ceiling grids.

2. 150W EC Motor with Stepless Speed Regulation

A brushless electronically commutated motor drives this backward curved centrifugal fan at 150W, keeping efficiency high across the operating speed range. The EC drive stays efficient when rpm drops, so this backward curved centrifugal fan can be slowed during low-occupancy shifts rather than cycled on and off, and its output can be trimmed steplessly instead of switched between fixed taps. In an FFU cabinet this lets the controller match fan speed to measured particulate, cutting both sound and power draw when the air is clean. Soft-start current limiting also protects the unit's own power board and contactor from startup surge on repeated daily cycling.

Product Overview

Product Overview

Product Overview

Product Overview

3. IP44 Sealing for Protected FFU and Cabinet Installations

The whole assembly is rated IP44, keeping solid foreign objects over 1mm out and resisting splashing water from any direction. That sealing level fits the typical FFU plenum and protected cleanroom cabinet, where the blower sits behind an intake panel rather than exposed to washdown hoses or heavy dust streams. Sealed around the windings and bearing, this backward curved centrifugal fan avoids the winding corrosion and bearing grit that shorten open-frame blower life in dusty rooms, while the IP44 housing avoids the added cost of full IP55 sealing where the environment does not demand it.

4. Class F Insulation and Wide Temperature Window

Winding insulation is Class F, giving this backward curved centrifugal fan thermal headroom for sustained full-load running inside a closed FFU plenum where airflow over the motor itself is limited. The specified ambient window of -25℃ to +60℃ covers cool plant rooms, heated commercial spaces and seasonal temperature swings without asking the unit to derate, and the S1 duty rating confirms this backward curved centrifugal fan is built for non-stop continuous duty rather than intermittent short bursts. The 230V/115V 50/60Hz supply matches two common commercial grids, keeping the same model compatible across export markets without a separate motor variant.

5. Shared 270mm Platform and Maintenance-Free Bearings

The two models in this family keep the same 270mm impeller envelope and 2 kg frame, so a ceiling cut-out or cabinet opening can be standardized while the internal power level varies by application. Sealed ball bearings run without a relubrication schedule, so this backward curved centrifugal fan needs no routine oiling over its service life, and the compact assembly simplifies installation into FFU housings and ducted ventilation units. Every unit carries ISO, BSCI, ETL, CE, EMC, RoHS and GS certification, confirming compliance with international safety, electromagnetic compatibility and environmental standards for air purification and ventilation equipment.

Application Scenarios

  • FFU Fan Filter Units: This backward curved centrifugal fan forms the pressure-generating core of fan filter units in cleanrooms, laboratory rooms and light industrial purification modules, holding HEPA airflow while keeping module noise acceptable for occupied spaces.
  • Cleanroom and Factory Ventilation: Mounted in ceiling grids and duct systems, this backward curved centrifugal fan supplies filtered make-up air and exhausts process heat in production halls where particulate control is required.
  • Air Purification Cabinets: Inside standalone purifiers and dust-collection cabinets, this backward curved centrifugal fan moves air through multi-stage filters, with the aluminum impeller suited to long service in dusty airstreams.
  • Enclosure and Equipment Cooling: In electrical enclosures and packaged industrial equipment, this backward curved centrifugal fan provides directed high-pressure airflow to heat sinks and control components, with IP44 protection for cabinet-mounted service.

Frequently Asked Questions

Q: Is this fan suitable for FFU applications? A: Yes. This backward curved centrifugal fan builds static pressure so it holds 1545 m³/h through HEPA media, and its 150W EC motor with stepless speed control lets an FFU match airflow to actual particle load while keeping noise and power draw low.

Q: What other model shares this 270mm platform? A: The companion LBBE3G270-092NU-01 shares the same aluminum alloy impeller, ball bearing, S1 duty and 2 kg frame. Its detailed power, speed and airflow figures should be checked against the variant datasheet before ordering.

Q: Can it run on 115V and 230V, and operate continuously? A: Yes to both. The rated input is 230V/115V at 50/60Hz, and this backward curved centrifugal fan is IP44 sealed, Class F insulated and S1 continuous duty, built for non-stop running within the -25℃ to +60℃ ambient range.

LBBE3G270-092NS-02 EC FFU Centrifugal Fan

LBBE3G270-092NS-02 EC backward curved centrifugal fan, aluminum alloy impeller, IP44 seal, 1545m³/h at 150W for FFU filter units and cleanrooms.

Request a Quote

Featured Products

lbbe3g270 092ns 02 ec ffu centrifugal fan-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000