ac-cooling-fan, ac-cooling-fan, /ac-cooling-fan
Inquiry
Inquiry

AC Cooling Fan

When operating under high thermal loads in heavy industrial machinery, cabinet ventilation cannot afford a single moment of weakness. Our heavy-duty AC Cooling Fan solutions provide relentless, high-volume airflow directly from main power lines, keeping your manufacturing plant floor running smoothly without the need for complex power conversion adapters.   Built to withstand extreme temperature fluctuations and high-voltage environments, our robust AC Cooling Fan lineup delivers unmatched structural reliability and mechanical durability, backed by decades of thermal-management manufacturing expertise.   Heavy-Duty Aluminum Alloy Frames & Steel Blades:  Unlike plastic fans that warp under extreme heat, our AC Cooling Fan units are constructed with die-cast aluminum housings and precision-balanced metal impellers. This rugged architecture prevents mechanical deformation, guaranteeing structural integrity and reliable airflow in high-temperature industrial kilns and welding environments. Direct Line Voltage Compatibility & Easy Integration: Simplify your electrical designs and reduce component failure points. Our AC Cooling Fan designs connect directly to standard 110V, 220V, or 380V power grids. This eliminates the cost, space, and weight associated with external AC-to-DC power converters, streamlined for rapid installation in heavy machinery cabinets.  On-Site Maintenance & Comprehensive Technical Training: We don't just ship products; we support your entire operational lifecycle. For complex cooling installations, we offer professional on-site maintenance, system overhaul services, and specialized operational skill training, ensuring your maintenance teams can maximize the uptime of every deployed AC Cooling Fan. Scalable Procurement with Tiered Pricing: Maximize the purchasing power of your long-term infrastructure budgets. Our structured tier-based pricing ensures that large-scale plant upgrades and bulk OEM partnerships receive maximum cost benefits, making our premium AC Cooling Fan models the most economically viable choice for industrial procurement.   Upgrade your heavy-duty machinery with the industry's most reliable thermal defense—request a comprehensive quote on our AC Cooling Fan models today and experience true operational peace of mind!       Severe Industrial Environments & Thermal Resistance Heavy industrial sectors such as metallurgy, chemical processing, and CNC machining demand thermal equipment that can survive environments that would immediately destroy standard commercial fans. The typical AC Cooling Fan in our catalog is engineered to thrive under these exact conditions. The secret lies in our advanced insulation systems and high-grade bearing architectures. We utilize Class B and Class F insulation materials in our AC Cooling Fan motor windings, allowing them to operate safely at internal temperatures exceeding 130°C.   This exceptional thermal resistance prevents electrical shorts and winding burnouts, which are the leading causes of fan failure in high-load industrial applications. By choosing our AC Cooling Fan, plant managers dramatically reduce unscheduled maintenance events and secure the continuous operating safety of their valuable production machinery.   Aerodynamic Efficiency & Noise Reduction Technology A common challenge with high-voltage AC-driven ventilation is the generation of excessive acoustic noise and vibration, which can fatigue mechanical structures and degrade the working environment. To address this, our R&D team has engineered the AC Cooling Fan with dual-ball bearing systems sourced from premier global manufacturers. These precision-engineered bearings minimize frictional resistance, ensuring exceptionally smooth rotation.   Additionally, every single AC Cooling Fan undergoes rigorous dynamic balancing tests on both the horizontal and vertical planes. This meticulous balancing process eliminates micro-vibrations that can cause structural fatigue in cabinet walls, while simultaneously reducing the overall noise output. The result is an AC Cooling Fan that delivers massive volumetric displacement without creating disruptive acoustic pollution on your factory floor.   Lifetime Support and Genuine Spare Parts Supply We believe that a world-class cooling fan must be paired with world-class lifecycle support. Over decades of serving international markets in Europe, Russia, India, and the Americas, we have refined our post-purchase support structure. Should an AC Cooling Fan require servicing after years of continuous operation in a harsh cement or chemical plant, our Genuine Spare Parts Supply guarantees that original replacement blades, balanced impellers, and high-temperature lubricants are shipped immediately to your facility.   By utilizing original, factory-certified components, you restore your AC Cooling Fan to its precise original operating specifications, preserving system balance and preventing premature motor wear. Combined with our 12-hour rapid-response technical support, our clients are never left to solve operational problems alone.     Advanced Die-Cast Housing and Impeller Craftsmanship To endure the mechanical strain of heavy-duty industrial environments, every heavy-duty AC Cooling Fan is manufactured utilizing precise, high-pressure die-cast aluminum alloys. This specialized manufacturing technique creates a highly dense, non-porous frame structure that exhibits exceptional tensile strength and superior resistance to physical impacts. Unlike standard commercial fans, our industrial AC Cooling Fan features magnesium-aluminum alloy or high-carbon steel blades. These rigid blades undergo electrostatic powder coating processes, yielding a thick, corrosion-resistant outer layer that protects the AC Cooling Fan from exposure to salt spray, humidity, and mild acids. This robust construction prevents dynamic blade deformation under high-speed operation, guaranteeing that the AC Cooling Fan delivers consistent static pressure and reliable volumetric flow rates over its entire operating lifetime.   High-Voltage Dielectric Safety and Surge Insulation Electrical safety is paramount in heavy machinery applications where high-voltage fluctuations and electrical spikes are common. Our AC Cooling Fan motors are designed with advanced dielectric protection systems. During production, every single AC Cooling Fan must pass a strict high-voltage insulation test (Hi-Pot test) exceeding 1500V AC for 60 seconds. The motor windings are wound with high-purity copper wires coated in multiple layers of modified polyimide film insulation. Additionally, we integrate automatic thermal-overload cut-off protectors within the AC Cooling Fan stator assembly. If the ambient temperature rises beyond safe limits or if the rotor becomes mechanically locked, the internal thermal protector immediately cuts off power to the AC Cooling Fan motor, preventing electrical fires and protecting the overall machine control system from cascading damage.   Seamless Logistics and Global Distribution Network Delivering heavy industrial hardware to remote project sites requires a robust, agile logistical framework. Over decades of serving global heavy industries, we have perfected our distribution channels across Europe, Russia, India, and the Americas. By optimizing our raw material supply chains and utilizing advanced automated assembly lines, we maintain a 98% on-time delivery rate for our AC Cooling Fan products. Whether you require a standard dual-voltage AC Cooling Fan for global export, or a highly customized, low-frequency model designed for specialized railway systems, our shipping team coordinates with top-tier international freight forwarding companies to ensure rapid custom clearance and dependable lead times. Our partners can confidently plan long-term capital investments, knowing that their critical AC Cooling Fan consignments will arrive exactly when needed.
Lobisong LBAA2D200S-7MKW-10 AC Axial Fan Ø200 mm

Lobisong LBAA2D200S-7MKW-10 AC Axial Fan Ø200 mm

The Lobisong LBAA2D200S-7MKW-10 is a reliable AC axial fan with a Ø200 mm impeller, designed for industrial ventilation and cooling. It delivers strong, steady airflow with low noise, making it suitable for HVAC systems, cold storage, air purifiers, and OEM equipment.

Lobisong LBAA2D200S-7MEB-06 AC Axial Fan Ø200 mm

Lobisong LBAA2D200S-7MEB-06 AC Axial Fan Ø200 mm

The Lobisong LBAA2D200S-7MEB-06 is a durable AC axial fan with a Ø200 mm impeller, engineered for industrial ventilation and cooling. It provides strong, consistent airflow with low noise, making it ideal for HVAC systems, cold storage, air purifiers, and OEM equipment.

Lobisong LBAA4E200S-5MEW-19 AC Axial Fan Ø200 mm

Lobisong LBAA4E200S-5MEW-19 AC Axial Fan Ø200 mm

The Lobisong LBAA4E200S-5MEW-19 is a high-performance AC axial fan with a 200 mm impeller, designed for reliable industrial ventilation and cooling. It delivers strong, steady airflow while keeping noise low, making it suitable for HVAC systems, cold storage, air purifiers, and OEM equipment.

Lobisong 185mm AC Axial Fan, Industrial Axial Ventilation Fan, Low Noise, for HVAC Systems, Cold Storage, Air Purifiers

Lobisong 185mm AC Axial Fan, Industrial Axial Ventilation Fan, Low Noise, for HVAC Systems, Cold Storage, Air Purifiers

The Lobisong 185mm AC Axial Fan is a reliable industrial axial ventilation fan designed for efficient air movement in demanding environments. With a compact 185mm frame, it delivers strong airflow while maintaining low noise, making it ideal for HVAC systems, cold storage, air purifiers, and other equipment requiring quiet, continuous cooling.

Lobisong LBAA2D185S-7MNW-03 AC Axial Fan Ø185 mm

Lobisong LBAA2D185S-7MNW-03 AC Axial Fan Ø185 mm

The Lobisong LBAA2D185S-7MNW-03 is a Ø185 mm AC axial fan corresponding to the LONGWELL LWAA2D185S-7MNW-03 platform, engineered for dependable fixed-speed ventilation in industrial and commercial environments.

Lobisong LBAA2D165S-5MNW-02 AC Axial Fan Ø165 mm

Lobisong LBAA2D165S-5MNW-02 AC Axial Fan Ø165 mm

The Lobisong LBAA2D165S-5MNW-02 is a Ø165 mm AC axial fan engineered for fixed-speed cooling in industrial and commercial applications.

Lobisong  185mm AC Axial Fan, Industrial Axial Ventilation Fan, 230V, Stainless Steel, for HVAC Systems, Cold Storage, Air Purifiers

Lobisong 185mm AC Axial Fan, Industrial Axial Ventilation Fan, 230V, Stainless Steel, for HVAC Systems, Cold Storage, Air Purifiers

Lobisong 185mm AC Axial Fan is a robust industrial ventilation fan designed for continuous air movement in demanding environments.

Lobisong LBAA2E185S-7MNW-01 AC Axial Fan Ø185 mm

Lobisong LBAA2E185S-7MNW-01 AC Axial Fan Ø185 mm

The Lobisong LBAA2E185S-7MNW-01 is a Ø185 mm AC axial fan engineered for reliable fixed-speed ventilation and heat dissipation in demanding industrial environments. 

Lobisong LBAA2D145S-5MNW-01 AC Axial Fan Ø145 mm

Lobisong LBAA2D145S-5MNW-01 AC Axial Fan Ø145 mm

Lobisong LBAA2D145S-5MNW-01 AC Axial Fan Ø145 mm — High-Efficiency Industrial Cooling Solution

Lobisong 102mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54 – LBBA4E315-102NS-11

Lobisong 102mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54 – LBBA4E315-102NS-11

Flexible Mounting – Supports both horizontal and vertical installation positions, offering versatility for equipment layout and space constraints.

225FLW2, 225FLW3 iron blade backward-curved vortex centrifugal fan, Lebisen fan

225FLW2, 225FLW3 iron blade backward-curved vortex centrifugal fan, Lebisen fan

The Lebisen 225FLW2 and 225FLW3 vortex centrifugal fans adopt durable iron backward-curved blades to achieve high air delivery efficiency for purification and industrial ventilation scenarios. Featuring solid metal impellers with dynamic balance treatment, these fans maintain stable airflow and static pressure while lowering vibration and running noise. Equipped with external rotor motors and built-in thermal protection, they are capable of long-duration continuous operation in demanding working environments. The two models provide differentiated air volume and pressure parameters to fit clean benches, dust collection equipment, cabinet heat dissipation and cleanroom air circulation systems. Widely selected by equipment manufacturers, engineering integrators and global bulk buyers, Lebisen centrifugal fans undergo rigorous performance inspections to deliver dependable and cost-effective air power solutions for electronics, pharmaceutical and factory air treatment industries.

250FLW2, 250FLW3 iron blade backward-curved vortex centrifugal fan

250FLW2, 250FLW3 iron blade backward-curved vortex centrifugal fan

The 250FLW2 and 250FLW3 vortex centrifugal fans feature sturdy iron backward-curved blades optimized for high-efficiency air delivery in industrial ventilation and purification systems. Designed with robust all-metal construction and dynamically balanced impellers, these blowers generate stable airflow and proper static pressure while reducing vibration and operational noise. Powered by external rotor motors with built-in thermal protection, they support extended continuous operation under heavy working conditions. The two models deliver different air volume and pressure outputs to accommodate clean benches, dust removal units, cabinet cooling and cleanroom air circulation. Preferred by equipment makers, system integrators and bulk international purchasers, this backward-curved centrifugal fan series passes strict performance testing to supply reliable, long-lasting air power solutions for electronics, pharmaceutical and workshop air treatment applications. 

175FLW2 Iron Blade R2E175-AC77-15 R2E175-AC77-05 All-metal turbine Centrifugal fan

175FLW2 Iron Blade R2E175-AC77-15 R2E175-AC77-05 All-metal turbine Centrifugal fan

The 175FLW2 all-metal turbine centrifugal fan is equipped with robust iron blades and available in two core model specifications, R2E175-AC77-15 and R2E175-AC77-05. Built with a full metal structure and dynamically balanced impellers, this centrifugal fan delivers consistent high-pressure airflow with low vibration and quiet continuous operation. Adopting mature external rotor motor technology, it features reliable heat resistance and overload protection to support long-cycle running in industrial environments. Widely adopted for air purification equipment, clean benches, cabinet ventilation, equipment heat dissipation and small air circulation systems, it meets diverse static pressure and air volume requirements. Suitable for equipment manufacturers, engineering integrators and bulk overseas buyers, this fan undergoes strict quality inspection to provide stable, cost-effective air power solutions for purification, electronics and light industrial ventilation projects.

220FLW22R2E220-AB06-05R2D220-RB14-09 Iron Blade all-metal Turbine Centrifugal fan

220FLW22R2E220-AB06-05R2D220-RB14-09 Iron Blade all-metal Turbine Centrifugal fan

Lebisen 280FLW2 and 280FLW3 all-metal vortex centrifugal fans are heavy-duty turbine blowers fitted with sturdy iron blades, engineered for stable high-static air supply in air purification and industrial ventilation projects. Built with full metal housing and precision dynamically balanced iron impellers, these FLW series fans adopt external rotor motor structure, delivering steady airflow, low vibration and quiet continuous running without extra volute assembly. Featuring reliable ball bearings and thermal protection, the units maintain consistent performance under long-hour operation and adapt well to clean benches, purification units, dust removal pipelines, equipment cooling and industrial air circulation systems. Available in two model variants for different air volume and pressure requirements, the Lebisen 280FLW2/280FLW3 purification turbine fans support flexible installation for system integrators and bulk buyers. Rigorously tested for industrial stability, this series serves cleanroom, pharmaceutical, electronics and workshop air treatment scenarios, offering durable, cost-effective centrifugal air power solutions for global B2B purchasers of ventilation and purification components.

All-metal 280FLW2/280FLW3 iron blade Lebisen brand vortex centrifugal fan purification turbine fan

All-metal 280FLW2/280FLW3 iron blade Lebisen brand vortex centrifugal fan purification turbine fan

The Lebisen 280FLW2 and 280FLW3 vortex centrifugal fans are premium all-metal purification turbine fans equipped with robust iron blades, purpose-built to deliver reliable high-pressure airflow for industrial air purification and ventilation applications. Constructed with full metal frames and dynamically balanced iron impellers, these FLW series centrifugal blowers adopt mature external rotor motor design to realize stable air output, minimized vibration and low noise during nonstop long-time operation. Integrated with high-quality bearings and overheat protection, they sustain consistent working performance in demanding industrial environments. The two models cater to differentiated air volume and static pressure demands, supporting versatile mounting methods to match clean benches, dust collection systems, industrial equipment cooling, cleanroom air circulation and other air treatment facilities. Widely supplied to system integrators, engineering contractors and bulk global buyers, Lebisen 280FLW2/280FLW3 turbine fans undergo strict performance testing, providing durable, economical air power solutions for electronics, pharmaceutical, food processing and workshop purification industries.

Turbo Centrifugal Fan 133&175&180&190&220&225&250&280FLW2&3 Industrial Silent Type

Turbo Centrifugal Fan 133&175&180&190&220&225&250&280FLW2&3 Industrial Silent Type

FLW2/FLW3 Turbo Centrifugal Fan Series: Covers 133, 175, 180, 190, 220, 225, 250, and 280 size designations for industrial air-movement projects.

Industrial Silent-Type Fan Family: The series is positioned for controlled centrifugal airflow in compatible equipment and ventilation assemblies.

Multi-Size Selection for Equipment Integration: Different size designations help buyers identify a suitable centrifugal fan reference for their installation.

Reference-Based Procurement Support: Confirm the exact FLW2 or FLW3 model, mounting arrangement, and equipment requirements before ordering.

Brand New W2E250-HL06-01&05&06&10&11&13&19&20&21 28080 Fan

Brand New W2E250-HL06-01&05&06&10&11&13&19&20&21 28080 Fan

W2E250 HK38/HH86 Axial Fan Series for Industrial Cooling: Nine HL06 variants and two HH86 references provide direct airflow for cabinets, machinery enclosures, and ventilation systems.

Outer-Rotor Motor with Copper Windings and Bearing Support: The shared motor construction supports stable operation in continuous-duty industrial air-movement applications.

220V/380V and 2450/2600 RPM Series Coverage: Family-level electrical and speed options support equipment matching across different installation requirements.

CAD and Technical Documentation Available: Engineering files, certification information, and technical references support selection, integration, and replacement planning.

Brand New W2E200-HK38-01 W2E200-HK38-07 W2E200-HK38-06 W2E200-HK38-05 W2E200-HK38-03 W2E200-HH86-C01 W2E200-HH86-16 Axial Fan

Brand New W2E200-HK38-01 W2E200-HK38-07 W2E200-HK38-06 W2E200-HK38-05 W2E200-HK38-03 W2E200-HH86-C01 W2E200-HH86-16 Axial Fan

W2E200 HK38/HH86 Axial Fan Series for Industrial Cooling: Seven model references provide direct airflow for cabinets, equipment enclosures, and ventilation systems.

Outer-Rotor Motor with Copper Windings and Bearing Support: The shared motor construction supports stable operation in continuous-duty industrial air-movement applications.

220V/380V and 2450/2600 RPM Series Coverage: Family-level electrical and speed options support equipment matching across different installation requirements.

CAD and Technical Documentation Available: Engineering files, certification information, and technical references support selection, integration, and replacement planning.