250FLW2, 250FLW3 iron blade backward-curved vortex centrifugal fan

The 250FLW2 and 250FLW3 vortex centrifugal fans feature sturdy iron backward-curved blades optimized for high-efficiency air delivery in industrial ventilation and purification systems. Designed with robust all-metal construction and dynamically balanced impellers, these blowers generate stable airflow and proper static pressure while reducing vibration and operational noise. Powered by external rotor motors with built-in thermal protection, they support extended continuous operation under heavy working conditions. The two models deliver different air volume and pressure outputs to accommodate clean benches, dust removal units, cabinet cooling and cleanroom air circulation. Preferred by equipment makers, system integrators and bulk international purchasers, this backward-curved centrifugal fan series passes strict performance testing to supply reliable, long-lasting air power solutions for electronics, pharmaceutical and workshop air treatment applications. 

Request a Quote
  • Overview

Overview

Product Summary

The 250FLW2 and 250FLW3 Iron Blade Backward-Curved Vortex Centrifugal Fans are heavy-duty industrial ventilation solutions engineered by Lobisong. Built with high-strength metallic impellers and driven by high-torque external rotor AC motors, these 250mm air movers deliver outstanding air delivery rates and high static pressure capabilities across demanding thermal systems. Featuring maintenance-free dual ball bearings, integrated thermal protection, and an anti-corrosive protective finish, the Lobisong 250FLW2 single-phase and 250FLW3 three-phase units ensure continuous, stable air movement, minimal mechanical vibration, and extended operational lifespan in telecommunications cabinets, frequency inverters, commercial HVAC systems, and industrial automation equipment.

250FLW2 (1).png

 

Overview

Modern high-density electrical enclosures, industrial machinery, and HVAC air processing equipment require compact yet powerful ventilation mechanisms capable of overcoming severe aerodynamic resistance. The Lobisong 250FLW2 and 250FLW3 Iron Blade Backward-Curved Vortex Centrifugal Fans are specifically engineered to address these challenging thermal management demands. By combining robust metallic impellers with an advanced backward curved aerodynamic wheel design, these 250mm industrial systems generate maximum static pressure while maintaining high volumetric air delivery efficiency.

The Lobisong 250FLW2 model operates on a single-phase AC power supply, whereas the Lobisong 250FLW3 model is optimized for three-phase industrial electrical infrastructures. Unlike conventional plastic impellers that warp under elevated heat or pressure, the heavy-duty iron blade structure provides exceptional structural rigidity and thermal resistance. The backward curved design pulls intake air axially into the hub assembly and discharges it radially through a vortex pathway, converting kinetic velocity into static pressure without aerodynamic stall or turbulence. Precision copper windings, dynamically balanced metal wheels, and sealed dual ball bearings ensure that this motor-driven product line achieves continuous, energy-efficient performance in harsh industrial processing environments.

detail250FLW2 (2).jpg

 

Features & Technical Advantages

1. Heavy-Duty Iron Blade Construction

This industrial product line utilizes high-tensile metallic impellers designed to withstand extreme thermal exposure and heavy mechanical stress. Each metallic wheel undergoes dynamic balancing to ISO 1940 Grade G2.5 standards, significantly minimizing operational vibration, reducing acoustic noise levels, and protecting motor bearings from premature wear during continuous high-speed rotation up to +70°C.

2. High Static Pressure Backward Curved Dynamics

The aerodynamic backward curved profile converts rotational kinetic energy into static pressure with optimal fluid efficiency. This specialized impeller geometry prevents airflow stalling when operating against steep system resistance curves, allowing the Lobisong equipment to drive steady air streams through dense HEPA filters, tight heat exchanger matrices, and intricate ductwork layouts.

3. Versatile Power Configurations (250FLW2 vs. 250FLW3)

To accommodate diverse global electrical infrastructures, Lobisong provides both single-phase (250FLW2) and three-phase (250FLW3) AC external rotor motor configurations. The 250FLW2 single-phase unit allows seamless integration into standard commercial AC power grids, while the 250FLW3 three-phase variant delivers optimized power factor efficiency, lower starting current spikes, and superior electrical stability in heavy machinery environments.

4. Advanced External Rotor AC Motor Engineering

Lobisong equips these products with an advanced external rotor AC motor embedded directly inside the metallic wheel hub. This space-saving design provides a compact axial footprint, superior motor self-cooling efficiency, and high rotational torque. Auto-reset thermal overload protectors shield internal motor windings against over-temperature conditions, phase loss, and locked-rotor events.

5. Superior Environmental Resilience and Lifespan

With IP44/IP54 ingress protection ratings, Class B/F insulation systems, and permanently lubricated dual ball bearings, these backward curved blowers deliver an L10 operational service life exceeding 50,000 hours at 40°C. The anti-corrosive electrocoating protects the metallic wheel structure from ambient humidity, industrial oil mist, and mild airborne chemical vapors.

detail250FLW2 (2).png

Technical Specifications

Parameter Technical Specification Value
Model Series Lobisong 250FLW2 (Single Phase) / Lobisong 250FLW3 (Three Phase)
Fan Type Iron Blade Backward-Curved Vortex Centrifugal Fan
Impeller Material Heavy-Duty Iron Blade / Pressed Sheet Steel
Impeller Diameter 250 mm
Rated Voltage 230 VAC (250FLW2) / 380 VAC - 400 VAC (250FLW3)
Operating Frequency 50 Hz / 60 Hz
Input Power 110 W - 180 W
Nominal Speed 1350 - 2650 RPM
Airflow Capacity 1100 - 1850 m³/h (647 - 1088 CFM)
Maximum Static Pressure 380 - 520 Pa
Bearing Assembly Precision Sealed Maintenance-Free Dual Ball Bearings
Insulation Grade Class B / Class F
Motor Protection Automatic Reset Thermal Overload Protection
Ingress Protection Rating IP44 / IP54
Operating Temperature Range -25°C to +70°C
Service Life Standard 50,000 Hours (L10 at 40°C)

 

Applications

The Lobisong 250FLW2 and 250FLW3 Iron Blade Backward-Curved Vortex Centrifugal Fans deliver reliable thermal management across industrial sectors:

  • Telecommunication Enclosures: Forced air cooling for outdoor 5G telecom shelters, server rooms, and remote electronic control cabinets.

  • Industrial Power Electronics: Heat dissipation for high-power variable frequency drives (VFD), power inverters, and power distribution units.

  • Commercial HVAC Systems: Ventilation in rooftop air handlers, heat recovery ventilators (HRV), commercial air purifiers, and laminar flow cleanrooms.

  • Industrial Machinery: Forced draft cooling for laser cutting machinery, CNC equipment, welding units, and plastics processing equipment.

  • Environmental Equipment: Air circulation for industrial dehumidifiers, commercial drying cabinets, and fume extraction systems.

 

Commercial Value & OEM Advantages

Partnering with Lobisong for the 250FLW2 single-phase and 250FLW3 three-phase series offers key commercial benefits for global B2B buyers:

  • Direct Manufacturer Cost Optimization: Lobisong delivers factory-direct engineering and competitive procurement pricing, significantly lowering total bill-of-materials (BOM) costs for OEM clients.

  • Reduced Operational Downtime & Maintenance Overhead: The robust metallic wheel construction and maintenance-free dual ball bearing system eliminate premature equipment failure, cutting field service calls.

  • Customized Engineering Support: Lobisong offers OEM customization including special lead wire lengths, custom connector terminals, mounting flanges, speed controllers, and tailored surface coatings.

  • Global Quality Compliance & Stable Supply: Produced under ISO9001 certified quality management and compliant with CE and RoHS standards, Lobisong ensures reliable volume production, strict quality control, and timely global shipping.

250FLW2, 250FLW3 iron blade backward-curved vortex centrifugal fan

The 250FLW2 and 250FLW3 vortex centrifugal fans feature sturdy iron backward-curved blades optimized for high-efficiency air delivery in industrial ventilation and purification systems. Designed with robust all-metal construction and dynamically balanced impellers, these blowers generate stable airflow and proper static pressure while reducing vibration and operational noise. Powered by external rotor motors with built-in thermal protection, they support extended continuous operation under heavy working conditions. The two models deliver different air volume and pressure outputs to accommodate clean benches, dust removal units, cabinet cooling and cleanroom air circulation. Preferred by equipment makers, system integrators and bulk international purchasers, this backward-curved centrifugal fan series passes strict performance testing to supply reliable, long-lasting air power solutions for electronics, pharmaceutical and workshop air treatment applications. 