DC Cooling Fan

In the high-stakes world of modern industrial electronics and telecommunications, a single micro-degree of heat buildup can trigger catastrophic system downtime. Our high-performance DC Cooling Fan systems deliver precise, dynamic, and energy-efficient thermal regulation, ensuring your critical hardware runs at peak performance under the most grueling continuous workloads.   Engineered for intelligent, low-power, and ultra-reliable thermal management, our industrial-grade DC Cooling Fan models provide the ultimate protection for heat-sensitive electronics with smart speed control and a proven 98% on-time global delivery guarantee.   Smart PWM Speed Control & Low Power Consumption: By utilizing advanced brushless DC motor technology, each DC Cooling Fan dynamically adjusts its rotational speed based on real-time system temperatures. This precise modulation reduces power consumption by up to 30% compared to traditional fans, significantly lowering your operational costs and extending the lifespan of your internal electronic components. Custom-Engineered IP56/IP68 Environmental Protection:   Moisture, dust, and corrosive gases are the silent killers of industrial hardware. We develop tailor-made DC Cooling Fan solutions featuring specialized conformal coatings and fully sealed motor housings, ensuring uninterrupted airflow and rugged durability even in the harshest marine, agricultural, or outdoor telecommunication environments. Flexible Tier-Based Volume Discounts:   Budget predictability is vital for your long-term project planning. We provide transparent, tier-based discounts according to your order quantities, allowing procurement managers to secure premium-quality DC Cooling Fan units at highly competitive unit prices while maximizing return on investment for large-scale industrial rollouts. 24/7 Global Technical Support & Fault Diagnosis:   Technical issues do not follow a standard 9-to-5 schedule. Our expert engineering team offers round-the-clock online guidance and advanced fault diagnosis for DC Cooling Fan integration, helping partners across Europe, Russia, India, and the Americas resolve complex cooling challenges in under 12 hours.   Don't let thermal bottlenecks compromise your equipment's lifespan—contact our engineering team today to customize your high-volume DC Cooling Fan solution and secure your project's exclusive volume discount!     Industrial Automation & Renewable Energy Integration The modern industrial landscape demands unprecedented levels of power density. Within server racks, solar inverters, and automated control cabinets, the heat generated by high-frequency switching transistors must be evacuated immediately. A standard thermal solution is no longer sufficient. Our specialized DC Cooling Fan series is engineered specifically to address these high-static-pressure requirements. By optimizing the blade aerodynamics through extensive computational fluid dynamics (CFD) testing, we have created a DC Cooling Fan blade profile that maximizes volumetric airflow while minimizing localized turbulence.   This advanced aerodynamic profile ensures that even in densely packed electronic enclosures where airflow impedance is extremely high, the DC Cooling Fan maintains a consistent, laminar stream of cooling air. This level of thermal reliability is why leading industrial automation partners from Europe to the Americas trust our DC Cooling Fan products to safeguard their multi-million dollar production lines.   Tailor-Made Engineering & Structural Adaptability No two industrial projects are identical. A DC Cooling Fan that works perfectly in a well-ventilated server room will fail rapidly in a dusty mining control panel or a humid coastal wind turbine. Recognizing this reality, our dedicated R&D division prioritizes Custom Engineering. We do not merely sell off-the-shelf products; we collaborate closely with your technical teams to modify the physical and electrical parameters of each DC Cooling Fan.   Whether your project requires custom lead wire lengths, specialized connector terminals, auto-restart protection, locked-rotor alarm signals (RD), or tachometer frequency generator outputs (FG), our custom engineering services adapt the DC Cooling Fan to integrate seamlessly with your proprietary control systems. This bespoke approach eliminates the need for costly retrofitting and accelerates your product's time-to-market.   Global Supply Chain Resilience & Maintenance Support In a globalized manufacturing economy, supply chain delays can halt entire assembly operations. We combat this volatility by maintaining a highly automated manufacturing facility that guarantees a 98% on-time delivery rate. When you integrate our DC Cooling Fan into your long-term production schedule, you are backed by a robust supply chain that utilizes advanced inventory forecasting.   Furthermore, our commitment to our partners extends far beyond the initial purchase. We actively support your operational continuity through our Genuine Spare Parts Supply. Original DC Cooling Fan blades, long-life ball bearings, and specialized motor components are constantly kept in stock and prepared for rapid global shipment. To ensure your local technicians can maximize the operational life of your cooling systems, we also offer comprehensive Maintenance & Technical Training programs, providing your staff with the technical expertise needed for routine overhauls and system optimizations.   Advanced Brushless DC Motor Engineering The beating heart of our DC Cooling Fan is the highly optimized brushless DC (BLDC) motor. Traditional brushed motors suffer from mechanical wear, frictional heat, and electromagnetic interference (EMI) due to constant brush-commutator contact. Our brushless DC Cooling Fan design entirely eliminates these vulnerabilities. By utilizing solid-state electronic commutation and premium permanent NdFeB (Neodymium Iron Boron) magnets, our DC Cooling Fan achieves exceptionally high magnetic flux density. This results in superior mechanical efficiency and a massive reduction in internal thermal losses. Furthermore, the electronic components of the DC Cooling Fan motor drive are isolated from the mechanical structure using high-grade, heat-conductive epoxy encapsulation. This ensures that the delicate driver ICs remain cool, preventing premature electrical degradation even during continuous 24/7 duty cycles.   Dynamic Balancing and Rotor Alignment Protocols Every single DC Cooling Fan assembly is subjected to a state-of-the-art, two-plane dynamic balancing process prior to final packaging. Micro-vibrations in a high-speed DC Cooling Fan can lead to rapid bearing wear, localized structural noise, and eventual fan failure. Our automated balancing machinery measures rotational imbalance down to the milligram level. Specialized counterweights are permanently applied to the inner rim of the DC Cooling Fan impeller to correct any non-concentric weight distribution. This meticulous alignment guarantees that the DC Cooling Fan operates with a vibration amplitude of less than 0.05 mm/s. By maintaining such strict tolerance limits, we minimize the radial and axial loads placed on our premium Japanese NMB ball bearings, allowing the DC Cooling Fan to easily achieve an L10 life expectancy exceeding 70,000 hours at 40°C.    Strategic Procurement Optimization for Industrial Projects Selecting the ideal thermal management system is not only a technical decision but also a critical financial strategy. When designing large-scale infrastructure, telecom networks, or medical imaging equipment, the long-term total cost of ownership (TCO) must be strictly managed. Our tier-based pricing structure is specifically structured to assist procurement departments in achieving significant cost savings. By locking in long-term bulk agreements for a specific DC Cooling Fan model, your organization secures a highly stable unit price, completely insulated from seasonal material cost fluctuations. Our logistics team integrates seamlessly with your enterprise resource planning (ERP) systems, offering Just-In-Time (JIT) deliveries that align with your weekly production schedules. Combined with our 12-hour technical support, this comprehensive commercial framework makes our DC Cooling Fan systems the most reliable, cost-effective, and performance-proven thermal solutions on the global market today.
LOBISONG LBG4010 Series
40mm x 40mm x 10.3mm
DC Axial Fan

LOBISONG LBG4010 Series 40mm x 40mm x 10.3mm DC Axial Fan

LOBISONG LBG4010 Series — 40 × 40 × 10.3 mm DC Axial Fan

The LOBISONG LBG4010 series is a compact DC axial fan built around the 40 × 40 × 10.3 mm form factor, a footprint widely used where board space is tight and forced convection is the only practical way to move heat out of an enclosure. The fan is offered in 5 V, 12 V, and 24 V DC versions, making it adaptable to USB-powered accessories, standard 12 V electronics, and 24 V industrial or 3D-printer control systems alike.

Across the series, airflow typically spans 4.85–6.66 CFM, with speed options in the 5,000–7,000 RPM range and power draw between 0.72 W and 1.44 W, depending on the voltage and speed grade selected. Static pressure reaches approximately 2.52–4.55 mm-H₂O, sufficient for pushing air through dense heatsink fins or narrow vent openings rather than simply stirring air in open space. Noise output ranges from roughly 20 dB(A) at the low-speed end to 28 dB(A) at the high-speed end, a level that remains acceptable in desktop equipment and consumer electronics but becomes noticeable in truly quiet environments.

The LBG4010 is available with sleeve bearing or ball bearing constructions. Sleeve-bearing versions are cost-effective and rated for approximately 30,000 hours at 25 °C, while ball-bearing variants extend service life to 40,000–50,000 hours and tolerate higher ambient temperatures up to 70 °C. Housings and impellers are molded from PBT UL 94V-0 flame-retardant plastic, and lead wires follow the UL 1007 26 AWG standard with red (+) and black (−) polarity marking. The fan also includes polarity protection, so reversing Vcc and GND will not destroy the circuit within a brief miswiring event.

Typical applications include 3D-printer hotend and part cooling, small power supplies, network appliances, medical instruments, and embedded control cabinets where a 40 mm opening is already defined and thermal headroom is limited. With its combination of low profile, multi-voltage availability, and bearing options spanning budget to long-life duty, the LBG4010 series fills a practical niche: it is small enough to fit almost anywhere, yet specified broadly enough to cover both intermittent consumer use and continuous industrial operation.

LOBISONG LBG4015 Series
40mm x 40mm x 15mm
DC Axial Fan

LOBISONG LBG4015 Series 40mm x 40mm x 15mm DC Axial Fan

LOBISONG LBG4015 Series — 40×40×15 mm DC Axial Fan

The LBG4015 Series is LOBISONG’s 40 mm square DC axial fan with a 15 mm frame depth, positioned for space-critical cooling in small enclosures and dense electronics. Public datasheets specific to the LBG4015 designation are not readily indexed, so the performance envelope below reflects the established 4015-class architecture this series belongs to rather than a single locked specification table.

Across the 4015 class, 5 V, 12 V, and 24 VDC inputs are standard. Speed options commonly span 4,000 RPM to 12,000 RPM, producing airflow from approximately 4.7 CFM on quiet low-speed variants up to 13–15 CFM at the high end. Maximum static pressure follows the same progression, from roughly 1.8 mmH₂O (≈17.6 Pa) at 4,000 RPM to 11.6 mmH₂O (≈114 Pa) at 10,000 RPM, with some high-speed versions reaching higher. Noise output tracks that range from the low-20s dBA on low-speed models to the low-40s dBA at maximum performance.

Construction uses a UL94V-0 thermoplastic frame and impeller, with sleeve or ball bearing options. Available functions typically include FG tachometer output, RD locked-rotor alarm, PWM speed control, reverse-polarity protection, and auto-restart, along with optional IPX5 protection for moisture-prone environments. Operating temperature spans −10°C to +70°C.

With its 40 mm footprint and 15 mm depth, the LBG4015 Series suits compact power adapters, 1U embedded systems, networking appliances, portable instruments, and small-form-factor enclosures where board space and height are both tightly constrained and targeted spot-cooling is required.

LOBISONG LBG4020 Series
40mm x 40mm x 20mm
DC Axial Fan

LOBISONG LBG4020 Series 40mm x 40mm x 20mm DC Axial Fan

The LOBISONG LBG4020 Series is a compact 40mm x 40mm x 20mm DC axial fan engineered for space-constrained cooling applications where reliable, targeted airflow is essential. As part of LOBISONG’s line of miniature brushless cooling fans, the LBG4020 balances performance, longevity, and low-noise operation within a standardized 4020 footprint.

Key Specifications & Options
The series typically supports 5V, 12V, or 24V DC inputs, accommodating common electronics and embedded-system power rails. Bearing choices directly influence service life: sleeve bearings offer a cost-effective solution rated around 30,000 hours, hydraulic bearings extend longevity to approximately 35,000 hours with quieter operation, and dual ball bearings deliver the longest lifespan—up to 50,000 hours—making them suitable for continuous-duty deployments. Airflow and speed vary by configuration; comparable 4020 fans achieve roughly 5–9 CFM at speeds between 5,000 and 8,500 RPM, with noise levels often kept in the 20–30 dBA range depending on the chosen bearing and speed profile.

Design & Integration
The 20mm thickness provides additional static pressure capability compared with thinner 10mm fans, helping overcome resistance in dense enclosures or heatsink assemblies. Common features across the 4020 class include PWM speed control, FG tachometer output, and optional IP-rated protection for dusty or humid environments. The compact square frame integrates easily into 3D printer hotend cooling, small-form-factor PC cases, network appliances (NAS, switches), and portable electronics where board space is at a premium.

Reliability & Customization
LOBISONG supports OEM/ODM flexibility on voltage, connector type, lead length, and bearing selection, allowing the LBG4020 to be tuned for specific acoustic or durability targets. With a focus on consistent airflow delivery in a minimal footprint, the LBG4020 Series serves as a practical thermal solution for compact, heat-sensitive designs.

LBMR4020 Series
40mm x 40mm x 20mm
DC Axial Fan

LBMR4020 Series 40mm x 40mm x 20mm DC Axial Fan

The LBMR4020 Series (closely related to the widely documented MR4020 platform) is a family of 40 mm × 40 mm × 20 mm DC axial fans that occupies the mid-profile position within the 40 mm fan ecosystem—thicker than ultra-slim 10 mm variants for greater thermal headroom, yet shallower than the 28 mm high-output series for tighter installations.

Bearing and construction. The series is built around a ball bearing system, a standard choice for continuous-duty applications that demand consistent performance and extended service life. The frame and impeller are molded from plastic, with each unit weighing approximately 24 g (0.053 lb), a lightweight profile suited to vibration-sensitive or weight-constrained assemblies. The series carries CE, cUL, TUV, and UL approvals, confirming compliance with major international safety and quality standards.

Performance envelope and feature options. The platform supports both 12 VDC and 24 VDC nominal inputs, with speeds spanning from 6,500 RPM to 12,000 RPM. Airflow ranges from 9.4 CFM (0.263 m³/min) on the low-speed end to 17.3 CFM (0.484 m³/min) in the highest-output configurations. Static pressure correspondingly climbs from 0.160 in H₂O (40.0 Pa) to 0.540 in H₂O (134.5 Pa) . Acoustic output remains tightly controlled across the range, from 26.5 dB(A) at 6,500 RPM to 41.0 dB(A) at 12,000 RPM.

A notable strength of the series is its feature granularity. Base models operate as simple 2-wire fans with Auto Restart protection. Mid-tier variants add Speed Sensor (Tachometer) output for RPM monitoring. Top-tier configurations incorporate both PWM speed control and tachometer feedback on a 4-wire interface, enabling closed-loop thermal regulation within the host system. All variants include locked rotor protection or auto-restart functionality to safeguard the motor against stall conditions.

Applications. The 40 × 20 mm form factor is widely deployed in compact electronic enclosures, server racks, industrial control equipment, and networking hardware where thermal management must be achieved within a slim vertical clearance. The LBMR4020 is the appropriate specification when a fixed 40 mm mounting pattern demands more airflow and pressure capability than a 10 mm fan can provide, but the installation depth cannot accommodate a 28 mm high-output model. Its combination of ball-bearing durability, flexible control options, and balanced acoustic performance makes it a pragmatic mid-tier thermal solution.

LBMD4028 Series
40mm x 40mm x 28mm
DC Axial Fan

LBMD4028 Series 40mm x 40mm x 28mm DC Axial Fan

The LBMD4028 Series occupies the highest-output tier of the 4028 platform, distinguished by its focus on maximum thermal performance through elevated rotational speeds and a feature set geared toward system-level monitoring and protection. It shares the 40 mm × 40 mm × 28 mm envelope with the LBH and LBMH variants, but its specification leans decisively toward pressure head and airflow delivery.

Bearing and construction. The series employs a ball bearing system, a standard choice for continuous-duty industrial and server applications where bearing longevity under sustained high-speed operation is critical. Frame and impeller are molded from UL94V-0 rated PBT, providing flame retardancy and thermal stability. A defining characteristic of the LBMD tier is its comprehensive protection and monitoring suite: many variants incorporate PWM speed control, tachometer (speed sensor) output, locked-rotor alarm signaling, and Thermal Overload Protection (TOP). This level of integration allows the fan to participate actively in closed-loop thermal management and fault-detection architectures, rather than operating as an uncontrolled fixed-speed device.

Performance envelope. The series supports 12 VDC and 24 VDC inputs, with speeds spanning from 8,000 RPM at the lower end to 15,000 RPM and beyond in high-output configurations. Airflow covers a broad range, with representative figures including 15.2 CFM (0.426 m³/min) at 10,300 RPM and 24.3 CFM (0.680 m³/min) at the 15,000 RPM ceiling. Static pressure reaches as high as 300.4 Pa (1.206 in H₂O) on the most aggressive 15,000 RPM variants, a pressure capability that positions the LBMD as a true high-impedance solution for dense heatsinks and restricted airflow paths. Acoustic output scales with speed, from roughly 44 dBA in mid-range models to approximately 53 dBA at maximum output.

Applications. The LBMD4028 is specified where a fixed 40 mm mounting pattern must support cooling loads that approach the practical limits of the 4028 form factor. Typical deployments include high-density server power supplies, telecommunications rectifiers, industrial drives, and compact thermal chambers where the fan must overcome significant system impedance while providing speed feedback and fault signaling to the host controller. It is the appropriate choice when the design demands not merely airflow, but monitored, protected, and dynamically controllable airflow within the 40 × 28 mm envelope.

LBH4028 Series
40mm x 40mm x 28mm
DC Axial Fan

LBH4028 Series 40mm x 40mm x 28mm DC Axial Fan

The LBH4028 Series is a 40 mm × 40 mm × 28 mm DC axial fan family that shares the 4028 form factor with the LBMH4028 but sits in a different position within the product hierarchy. While the LBMH variants emphasize advanced control features such as PWM, tachometer output, and thermal overload protection, the LBH designation points toward a more standard high-output configuration, built around a robust dual ball bearing system for durability in continuous-duty applications.

Bearing, materials, and construction. The series relies on dual ball bearings, a choice that favors resistance to wear and consistent performance over extended operating hours compared with sleeve-bearing designs. Frame and impeller are molded from PBT plastic, and the fan carries an insulation Class A rating with an operating temperature window of −10°C to 70°C. Weight is listed at approximately 40–60 g depending on the specific variant and optional features. Available function options across the 4028 platform include FG (tachometer), RD (rotation detection), PWM, and VC (voltage control), allowing the LBH4028 to be specified with or without speed monitoring depending on the application.

Performance envelope. The series supports 12 VDC and 24 VDC nominal inputs. Across the 4028 platform, speeds span from 6,000 RPM at the low end to 22,000 RPM in the highest-output configurations, with airflow reaching approximately 8.2 to 30.0 CFM (0.23–0.85 m³/min) and static pressure climbing as high as 68 mmAq (2.68 in H₂O) on the most aggressive variants. Noise scales from the low 30s dBA at 6,000 RPM to roughly 56 dBA at maximum speed. A representative 12 V variant at 18,000 RPM delivers 24.6 CFM at 45.7 mmAq and 52.8 dBA, illustrating the pressure-oriented tuning characteristic of the higher-speed LBH configurations.

Applications. The 4028 depth is particularly valued where 40 mm mounting is fixed but cooling demand exceeds slim-fan capability. Typical deployments include server PSU cooling, network and communication equipment, industrial control modules, and compact electronic enclosures where the fan must push air through dense component arrays or restricted internal pathways. The LBH4028 is the appropriate specification when a straightforward, durable ball-bearing fan is preferred over a feature-rich PWM-controlled model, while still demanding the thermal headroom that only a 28 mm-thick 40 mm fan can provide.

LBMH4028 Series
40mm x 40mm x 28mm
DC Axial Fan

LBMH4028 Series 40mm x 40mm x 28mm DC Axial Fan

The LBMH4028 Series is a family of 40 mm × 40 mm × 28 mm DC axial fans designed for applications where a thicker profile is acceptable in exchange for substantially higher static pressure and airflow than standard 40 mm fans can provide. Its 28 mm depth positions it as a high-output alternative for thermal challenges that a 10 mm or 20 mm fan cannot overcome.

Design and bearing system. The series is built around a ball bearing construction, a choice that favors durability and consistent performance over extended service life compared with sleeve-bearing alternatives. Frame and impeller materials are plastic, keeping weight to approximately 40 g per unit. The available feature set across the series is notably rich: many variants carry PWM speed control, tachometer output, auto-restart, and thermal overload protection (TOP), while select models add Parylene coating for enhanced environmental resilience. These options allow the fan to be integrated into closed-loop thermal control architectures rather than simply run at full speed.

Performance envelope. The series spans 12 VDC and 24 VDC nominal inputs, with speeds ranging from 8,000 RPM at the low end to 18,000 RPM in high-output configurations. Airflow covers approximately 11.4 to 27.9 CFM (0.32–0.79 m³/min) , and static pressure reaches as high as 330 Pa (1.325 in H₂O) on the most aggressive 12 V model. Noise scales accordingly, from roughly 38 dBA in low-speed variants to the low 60s dBA at maximum output. A mid-range 24 V example delivers 21.1 CFM at 219.2 Pa and 52 dBA, illustrating the balance the series strikes between pressure head and acoustic cost.

Applications. The 4028 form factor is widely used in 1U/2U server cooling, networking hardware, battery thermal management for energy-storage systems, and compact industrial enclosures where depth is less constrained than face area. The higher static pressure capability makes it particularly effective when pushing air through dense heatsink fins or across tightly packed components, a role poorly served by thinner 40 mm fans.

In short, the LBMH4028 Series trades footprint depth for thermal authority. It is the appropriate selection when a 40 mm mounting pattern is fixed but the cooling demand exceeds what a slim profile can deliver.

LBM5210 Series
52mm x 52mm x 10mm
DC Axial Fan

LBM5210 Series 52mm x 52mm x 10mm DC Axial Fan

The LBM5210 Series is a line of 52 mm × 52 mm × 10 mm DC axial fans engineered for space-constrained thermal management where conventional fans cannot fit. This compact footprint delivers a balance of airflow and static pressure, making it suitable for dense electronics, networking equipment, and portable enclosures.

Design and Construction. The impeller and frame are molded from UL94V-0 rated PBT, offering flame retardancy and dimensional stability in demanding environments. The series typically offers a choice of ball bearing or sleeve bearing systems, allowing designers to prioritize either longer service life or cost efficiency. Standard lead wires are AWG 26 UL1007, and impedance protection is commonly included to safeguard the motor against current anomalies. Some variants also provide an optional tachometer output signal for speed monitoring.

Performance Range. The series supports 5 VDC and 12 VDC nominal inputs, with operating voltage windows that accommodate supply fluctuations. Depending on the model, speeds range from 4,000 RPM to 6,000 RPM, producing airflow of approximately 0.22 to 0.32 m³/min (8–11.3 CFM) and static pressure up to 3.7 mm H₂O (0.15 in H₂O) . Noise levels remain in the 24–36 dB(A) range, a practical envelope for noise-sensitive equipment. At the high-output end, the fan delivers 11.3 CFM at 6,000 RPM while consuming roughly 1.4–1.7 W, depending on the winding and bearing configuration.

Applications. The 52 mm square format is widely adopted in 1U/2U rack servers, network switches, power supplies, medical instruments, and industrial control cabinets. Its shallow 10 mm depth allows integration into low-profile chassis without sacrificing cooling headroom. The combination of a ribbed frame, polarity protection, and auto-restart functionality supports reliable continuous operation in commercial and industrial settings.

In summary, the LBM5210 Series addresses the persistent engineering challenge of fitting meaningful forced convection into minimal volume. It offers a pragmatic thermal solution for compact, high-density systems that demand dependable airflow without excessive acoustic penalty.

LBMB6010 Series
60mm x 60mm x 10mm
DC Axial Fan

LBMB6010 Series 60mm x 60mm x 10mm DC Axial Fan

LOBISONG LBMB6010 Series — 60×60×10 mm DC Axial Fan

The LBMB6010 Series is LOBISONG’s 10 mm-ultrathin 60 mm square DC axial fan, the slimmest profile in the company’s 60 mm lineup. Public datasheets specific to the LBMB6010 designation are not readily available, so the performance envelope below reflects the broader 6010-class architecture this series belongs to rather than a single locked specification table.

Across the 6010 class, 5 V, 12 V, and 24 VDC inputs are standard, with speed options typically spanning 2,700 to 5,300 RPM. Airflow ranges from roughly 9.3 CFM on the lowest-speed variants to 18.7 CFM at the high end, while maximum static pressure scales from about 1.0 mmH₂O to 3.3 mmH₂O depending on the speed grade. Noise output tracks that progression from 19 dBA on quiet low-speed models up to 35 dBA at maximum RPM. Bearing choices include sleeve (lower cost, shorter service life) and ball bearing (extended life, better heat tolerance), and the frame and impeller are molded from UL94V-0 PBT for flame resistance. Unit weight is approximately 26 g.

Control and protection options follow LOBISONG’s standard 60 mm feature set: FG tachometer output, RD locked-rotor alarm, PWM speed control, reverse-polarity protection, and auto-restart. Operating temperature typically spans −10°C to +70°C, with storage tolerance down to −40°C.

The 10 mm depth makes the LBMB6010 the only viable choice when even a 15 mm or 20 mm fan will not clear the enclosure. Typical applications include 1U and blade-server slots, ultra-slim power supplies, credit-card-sized embedded boards, portable medical instruments, and dense portable electronics where height is the binding constraint and moderate airflow at low static pressure is sufficient.

LBG6015 Series
60mm x 60mm x 15mm
DC Axial Fan

LBG6015 Series 60mm x 60mm x 15mm DC Axial Fan

Mechatronics G6015 Series — 60×60×15 mm DC Axial Fan

The G6015 Series is Mechatronics’ 15 mm-thin 60 mm square DC axial fan, the slimmest profile in the 60 mm class and the go-to choice when board-to-enclosure clearance rules out a 20 mm or 25 mm frame. The series is organized as a six-tier speed matrix—G6015S, L, M, H, E, and X—so designers can pick the exact operating point rather than accept a single one-size compromise.

Across the range, speed spans 2,800 to 5,800 RPM, airflow climbs from approximately 11.0 to 24.0 CFM, and maximum static pressure rises from 0.32 to 0.68 mmH₂O. Noise tracks that progression from 21 dBA on the quiet S-tier to 35 dBA at the X-tier maximum. Nominal inputs cover 5, 12, and 24 VDC, with current draw scaling from 90 mA on low-speed variants to roughly 350 mA at the high end.

Construction uses a UL94V-0 PBT frame and impeller, ball bearings for extended service life, and a ribbed frame for structural rigidity. Standard protection includes reverse polarity and locked-rotor safeguards, while available options add tachometer output, locked-rotor alarm, PWM speed control, and encapsulated motors for dust- and moisture-prone environments. Select models carry an IP57 rating for washdown-adjacent or outdoor-adjacent installations.

With its 15 mm depth, the G6015 Series suits 1U rack equipment, slim power supplies, compact networking devices, embedded computing boards, and portable instrumentation—applications where every millimeter of height matters and moderate airflow at low-to-moderate static pressure is sufficient.

LBMD6020 Series
60mm x 60mm x 20mm
DC Axial Fan

LBMD6020 Series 60mm x 60mm x 20mm DC Axial Fan

LOBISONG LBMD6020 Series — 60×60×20 mm DC Axial Fan

The LBMD6020 Series is LOBISONG’s 20 mm-thin 60 mm DC axial fan, the slimmest profile in the company’s 60 mm square lineup. Public datasheets specific to the LBMD6020 designation are not readily available, so the performance envelope below reflects the broader 6020-class architecture this series belongs to rather than a single locked specification table.

Across the 6020 class, 5 V, 12 V, and 24 VDC inputs are standard, with speed options typically spanning 3,000 to 5,300 RPM. Airflow ranges from roughly 13 CFM to 29 CFM, and static pressure scales from about 2.0 mmH₂O on low-speed variants to 7.0 mmH₂O at the high end. Noise output tracks that progression from the mid-20s dBA on quiet low-speed models up to the low-40s dBA at maximum RPM. Bearing choices include sleeve (shorter service life, lower cost) and ball bearing (extended life, better heat tolerance), and the frame and impeller are molded from UL94V-0 PBT for flame resistance.

Control and protection options follow LOBISONG’s standard 60 mm feature set: FG tachometer output, RD locked-rotor alarm, PWM speed control, polarity protection, and auto-restart. Operating temperature typically spans −10°C to +70°C.

The 20 mm depth makes the LBMD6020 the choice when vertical clearance is the binding constraint and a 25 mm fan will not fit. Typical applications include slim power supplies, 1U/2U rack equipment, compact networking devices, portable instruments, and dense PCB enclosures where every millimeter of height matters and moderate static pressure is sufficient.

LBF6025 Series
60mm x 60mm x 25mm
DC Axial Fan

LBF6025 Series 60mm x 60mm x 25mm DC Axial Fan

LOBISONG LBF6025 Series — 60×60×25 mm DC Axial Fan

The LBF6025 Series is a 60 mm square DC axial fan with a 25 mm frame depth, sharing the compact footprint of the LBH and LBMR lines but tuned for a different balance of airflow and pressure. Public datasheets specific to the LBF6025 designation are limited, so the performance envelope below reflects the broader 6025-class architecture that this series belongs to rather than a single locked specification table.

Across the 6025 class, 12 VDC and 24 VDC inputs are standard, with 5 V and 48 V variants appearing in some catalogs. Speed options commonly span 2,500 to 4,600 RPM, producing airflow from roughly 13 CFM to 26 CFM and static pressure from about 1.15 mmH₂O to 6.16 mmAq depending on the selected speed grade. Noise output tracks that range from the low-20s dBA on quiet low-speed models up to the mid-30s dBA at the high end. Bearing choices include sleeve (≈30,000 h) and ball bearing (≈50,000 h at 40°C), and the frame and impeller are molded from UL94V-0 PBT.

Control and protection options include FG tachometer, RD alarm, PWM speed control, auto-restart, and polarity protection, matching the feature set expected across LOBISONG’s 60 mm families. Typical applications include compact power supplies, networking equipment, control cabinets, and general-purpose enclosure cooling where a 25 mm profile and moderate static pressure are sufficient.

LbMR6025 Series
60mm x 60mm x 25mm
DC Axial Fan

LbMR6025 Series 60mm x 60mm x 25mm DC Axial Fan

LOBISONG LBMR6025 Series — 60×60×25 mm DC Axial Fan

The LBMR6025 Series is LOBISONG's standard-profile 60 mm DC axial fan, using a 25 mm frame that fits applications where the deeper 38 mm class is not viable. The series is built around a broad speed matrix rather than a single operating point: depending on the selected model, airflow spans approximately 17.1 to 39.0 CFM, speed ranges from 3,500 to 8,000 RPM, and noise output scales from 31 dBA at the quiet end to 51 dBA at maximum performance.

Electrical options center on 12 VDC and 24 VDC nominal inputs, with current draw rising from roughly 0.05–0.09 A on low-speed variants to 0.18–0.36 A on the highest-speed models. Maximum static pressure follows the same progression, from approximately 3.56 mmH₂O at 3,500 RPM up to 18.54 mmH₂O at 8,000 RPM. Bearing construction is available in sleeve or ball bearing configurations, and the frame and impeller are molded from UL94V-0 PBT plastic for flame resistance.

For system-level control, the LBMR6025 supports FG tachometer output, RD locked-rotor alarm, and PWM speed control, alongside auto-restart and polarity protection as standard motor safeguards. Operating temperature is rated from −10°C to +70°C, with storage tolerance down to −40°C.

Typical applications include compact power supplies, telecom and networking equipment, industrial control panels, instrument enclosures, and stage-lighting or engraving equipment—installations that need a slim 60 mm fan with enough head pressure to push air through moderately dense internal layouts without resorting to a thicker, noisier high-static-pressure design.

LBH6025 Series
60mm x 60mm x 25mm
DC Axial Fan

LBH6025 Series 60mm x 60mm x 25mm DC Axial Fan

LOBISONG LBH6025 Series — 60×60×25 mm DC Axial Fan

The LBH6025 Series is a 60 mm square DC axial fan with a 25 mm frame depth, positioned as a balanced thermal solution for enclosures where a 38 mm-thick fan would exceed the available clearance. The series spans a broad performance envelope: depending on voltage and speed variant, it delivers airflow in the range of approximately 17 to 54 CFM, static pressure up to around 26 mmH₂O, and speed options from 3,000 RPM up to 10,000 RPM at the high end. Noise output correspondingly ranges from the high-20s dBA for low-speed quiet variants up to the mid-50s dBA at maximum performance.

The series accommodates 5 V, 12 V, 24 V, and 48 VDC nominal inputs, with power draw scaling from under 1 W at the low-speed end to several watts at maximum RPM. Bearing options typically include sleeve, hydraulic sleeve, and dual ball bearing, with ball-bearing construction supporting an expected life of up to 70,000 hours under favorable conditions. Frame and impeller are molded from UL94V-0 thermoplastic PBT, and optional functions include FG tachometer, RD alarm, PWM control, and locked-rotor protection.

With its slim 25 mm profile and wide voltage/speed matrix, the LBH6025 Series suits compact power supplies, telecom and networking equipment, inverter and UPS cooling, medical devices, and space-restricted control cabinets—applications that need reliable axial airflow without the depth penalty of a high-static-pressure fan.

LBMS6038 Series
60mm x 60mm x 38mm
DC Axial Fan

LBMS6038 Series 60mm x 60mm x 38mm DC Axial Fan

LBMS6038 Series — 60×60×38 mm DC Axial Fan

The LBMS6038 Series is a high-static-pressure DC axial fan engineered for space-constrained thermal management where airflow alone is insufficient. Its 38 mm depth enables a more aggressive impeller than standard 25 mm-thick 60 mm fans, generating static pressures up to 398.6 Pa (1.60 in H₂O) while delivering 31–58 CFM across the speed range of 6,000–11,000 RPM.

The series supports 12, 24, and 48 VDC inputs, with power consumption scaling from approximately 3.2 W at the low-speed end to 16.2 W at maximum performance. Noise output spans 39–59 dBA, allowing designers to select a low-noise variant for sensitive enclosures or a high-RPM variant when cooling margin is critical.

For system integration, the fan offers PWM speed control, tachometer (FG) output, and locked-rotor alarm options, alongside IP68 protection and conformal coating for harsh environments. The frame and impeller are constructed from UL94V-0 PBT plastic, with ball-bearing construction for long service life.

Typical applications include server and telecom rectifier cooling, industrial control cabinets, automotive electronics, CCTV systems, and compact power supplies where a 60 mm footprint must move meaningful air against dense component arrays. The LBMS6038 Series bridges the gap between compact size and serious thermal performance.

LOBISOONG LBA6038 Series
60mm x 60mm x 38mm
DC Axial Fan

LOBISOONG LBA6038 Series 60mm x 60mm x 38mm DC Axial Fan

LOBISOONG LBA6038 Series — 60×60×38mm DC Axial Fan

The LOBISOONG LBA6038 series is a high-static-pressure DC axial fan built in the compact 60mm × 60mm × 38mm format. The extra thickness over standard 25mm fans allows a deeper blade profile and a more powerful motor, making this series suited to applications where back pressure is significant and ordinary slim fans stall.

Performance Range. Typical 6038-class fans are offered in 12V, 24V, and 48V DC versions. Speed spans roughly 6,000 to 11,000 RPM, producing airflow from around 26 CFM to 58 CFM depending on the grade. Static pressure is the defining strength of this size: high-speed variants reach approximately 1.6 in H₂O (≈400 Pa), enough to push air through dense heatsinks, filters, or narrow ducting. Noise correspondingly ranges from about 39 dBA at the low end to 59 dBA at full speed.

Construction & Reliability. The frame and impeller are commonly molded from UL 94V-0 rated PBT thermoplastic with glass-fiber reinforcement for rigidity. Dual ball bearings are standard in this class, with operating life often rated at 70,000 hours and locked-rotor protection available. Optional PWM control, tach output, and IP68 sealing support speed regulation and harsh-environment use.

Typical Applications. The 6038 format is widely used in servers, telecom equipment, stage lighting, industrial power supplies, and compact inverter or battery-fixture cooling, where a 60mm footprint must still deliver meaningful pressure.

Note: Specifications vary by exact LBA6038 part suffix. Confirm voltage, airflow curve, bearing type, and noise with the official LOBISOONG datasheet for the specific configuration.

LOBISONG LBG8015 Series
80mm x 80mm x 15mm
DC Axial Fan

LOBISONG LBG8015 Series 80mm x 80mm x 15mm DC Axial Fan

LOBISONG LBG8015 Series — 80×80×15mm DC Axial Fan

The LOBISONG LBG8015 series is a slim-profile brushless DC axial fan designed for space-constrained thermal management. Measuring 80mm × 80mm × 15mm, it delivers reliable forced-air cooling where standard 25mm-thick fans cannot fit, making it a practical choice for compact electronics and dense equipment layouts.

Electrical & Performance Options. The series is typically available in 5V, 12V, 24V, and 48V DC versions to suit different system rails. Speed ranges commonly span from 1,800 RPM to 4,800 RPM, producing airflow in the range of approximately 20–48 CFM depending on the speed grade and blade design. Static pressure reaches up to roughly 0.23 in H₂O (57.3 Pa) at the high end, sufficient for pushing air through moderately restrictive vents or heatsink fins.

Bearing & Life. Units are offered with sleeve bearings for cost-sensitive, low-noise applications, or dual ball bearings for higher durability and wider temperature tolerance—ball-bearing variants are often rated for 70,000 hours of operation. Motor construction is 4-pole brushless DC, with locked-rotor protection available on higher-tier models.

Construction & Compliance. The frame and impeller are typically molded from UL 94V-0 rated PBT thermoplastic, offering flame resistance and dimensional stability. Standard lead wires are UL1007 AWG22/24 with red (+) and black (–) polarity; 2-wire, 3-wire (tach/FG), and PWM variants may be available depending on configuration. Many 8015-class fans carry UL, CE, and RoHS certifications, and IP-protected versions exist for dusty or splash-prone environments.

Typical Applications. Thanks to its 15mm thickness, the LBG8015 series is well suited for compact power supplies, network appliances, projectors, LED drivers, embedded PCs, and portable instrumentation where vertical clearance is limited but active cooling is still required.

Note: For definitive voltage ratings, airflow curves, noise levels, and bearing-life figures for a specific LBG8015 part number, request the official LOBISONG datasheet or confirm the exact model suffix with the supplier, as specifications vary by configuration.