dc-cooling-fan_4, dc-cooling-fan_4, /dc-cooling-fan
Inquiry
Inquiry

DC Cooling Fan

In the high-stakes world of modern industrial electronics and telecommunications, a single micro-degree of heat buildup can trigger catastrophic system downtime. Our high-performance DC Cooling Fan systems deliver precise, dynamic, and energy-efficient thermal regulation, ensuring your critical hardware runs at peak performance under the most grueling continuous workloads.   Engineered for intelligent, low-power, and ultra-reliable thermal management, our industrial-grade DC Cooling Fan models provide the ultimate protection for heat-sensitive electronics with smart speed control and a proven 98% on-time global delivery guarantee.   Smart PWM Speed Control & Low Power Consumption: By utilizing advanced brushless DC motor technology, each DC Cooling Fan dynamically adjusts its rotational speed based on real-time system temperatures. This precise modulation reduces power consumption by up to 30% compared to traditional fans, significantly lowering your operational costs and extending the lifespan of your internal electronic components. Custom-Engineered IP56/IP68 Environmental Protection:   Moisture, dust, and corrosive gases are the silent killers of industrial hardware. We develop tailor-made DC Cooling Fan solutions featuring specialized conformal coatings and fully sealed motor housings, ensuring uninterrupted airflow and rugged durability even in the harshest marine, agricultural, or outdoor telecommunication environments. Flexible Tier-Based Volume Discounts:   Budget predictability is vital for your long-term project planning. We provide transparent, tier-based discounts according to your order quantities, allowing procurement managers to secure premium-quality DC Cooling Fan units at highly competitive unit prices while maximizing return on investment for large-scale industrial rollouts. 24/7 Global Technical Support & Fault Diagnosis:   Technical issues do not follow a standard 9-to-5 schedule. Our expert engineering team offers round-the-clock online guidance and advanced fault diagnosis for DC Cooling Fan integration, helping partners across Europe, Russia, India, and the Americas resolve complex cooling challenges in under 12 hours.   Don't let thermal bottlenecks compromise your equipment's lifespan—contact our engineering team today to customize your high-volume DC Cooling Fan solution and secure your project's exclusive volume discount!     Industrial Automation & Renewable Energy Integration The modern industrial landscape demands unprecedented levels of power density. Within server racks, solar inverters, and automated control cabinets, the heat generated by high-frequency switching transistors must be evacuated immediately. A standard thermal solution is no longer sufficient. Our specialized DC Cooling Fan series is engineered specifically to address these high-static-pressure requirements. By optimizing the blade aerodynamics through extensive computational fluid dynamics (CFD) testing, we have created a DC Cooling Fan blade profile that maximizes volumetric airflow while minimizing localized turbulence.   This advanced aerodynamic profile ensures that even in densely packed electronic enclosures where airflow impedance is extremely high, the DC Cooling Fan maintains a consistent, laminar stream of cooling air. This level of thermal reliability is why leading industrial automation partners from Europe to the Americas trust our DC Cooling Fan products to safeguard their multi-million dollar production lines.   Tailor-Made Engineering & Structural Adaptability No two industrial projects are identical. A DC Cooling Fan that works perfectly in a well-ventilated server room will fail rapidly in a dusty mining control panel or a humid coastal wind turbine. Recognizing this reality, our dedicated R&D division prioritizes Custom Engineering. We do not merely sell off-the-shelf products; we collaborate closely with your technical teams to modify the physical and electrical parameters of each DC Cooling Fan.   Whether your project requires custom lead wire lengths, specialized connector terminals, auto-restart protection, locked-rotor alarm signals (RD), or tachometer frequency generator outputs (FG), our custom engineering services adapt the DC Cooling Fan to integrate seamlessly with your proprietary control systems. This bespoke approach eliminates the need for costly retrofitting and accelerates your product's time-to-market.   Global Supply Chain Resilience & Maintenance Support In a globalized manufacturing economy, supply chain delays can halt entire assembly operations. We combat this volatility by maintaining a highly automated manufacturing facility that guarantees a 98% on-time delivery rate. When you integrate our DC Cooling Fan into your long-term production schedule, you are backed by a robust supply chain that utilizes advanced inventory forecasting.   Furthermore, our commitment to our partners extends far beyond the initial purchase. We actively support your operational continuity through our Genuine Spare Parts Supply. Original DC Cooling Fan blades, long-life ball bearings, and specialized motor components are constantly kept in stock and prepared for rapid global shipment. To ensure your local technicians can maximize the operational life of your cooling systems, we also offer comprehensive Maintenance & Technical Training programs, providing your staff with the technical expertise needed for routine overhauls and system optimizations.   Advanced Brushless DC Motor Engineering The beating heart of our DC Cooling Fan is the highly optimized brushless DC (BLDC) motor. Traditional brushed motors suffer from mechanical wear, frictional heat, and electromagnetic interference (EMI) due to constant brush-commutator contact. Our brushless DC Cooling Fan design entirely eliminates these vulnerabilities. By utilizing solid-state electronic commutation and premium permanent NdFeB (Neodymium Iron Boron) magnets, our DC Cooling Fan achieves exceptionally high magnetic flux density. This results in superior mechanical efficiency and a massive reduction in internal thermal losses. Furthermore, the electronic components of the DC Cooling Fan motor drive are isolated from the mechanical structure using high-grade, heat-conductive epoxy encapsulation. This ensures that the delicate driver ICs remain cool, preventing premature electrical degradation even during continuous 24/7 duty cycles.   Dynamic Balancing and Rotor Alignment Protocols Every single DC Cooling Fan assembly is subjected to a state-of-the-art, two-plane dynamic balancing process prior to final packaging. Micro-vibrations in a high-speed DC Cooling Fan can lead to rapid bearing wear, localized structural noise, and eventual fan failure. Our automated balancing machinery measures rotational imbalance down to the milligram level. Specialized counterweights are permanently applied to the inner rim of the DC Cooling Fan impeller to correct any non-concentric weight distribution. This meticulous alignment guarantees that the DC Cooling Fan operates with a vibration amplitude of less than 0.05 mm/s. By maintaining such strict tolerance limits, we minimize the radial and axial loads placed on our premium Japanese NMB ball bearings, allowing the DC Cooling Fan to easily achieve an L10 life expectancy exceeding 70,000 hours at 40°C.    Strategic Procurement Optimization for Industrial Projects Selecting the ideal thermal management system is not only a technical decision but also a critical financial strategy. When designing large-scale infrastructure, telecom networks, or medical imaging equipment, the long-term total cost of ownership (TCO) must be strictly managed. Our tier-based pricing structure is specifically structured to assist procurement departments in achieving significant cost savings. By locking in long-term bulk agreements for a specific DC Cooling Fan model, your organization secures a highly stable unit price, completely insulated from seasonal material cost fluctuations. Our logistics team integrates seamlessly with your enterprise resource planning (ERP) systems, offering Just-In-Time (JIT) deliveries that align with your weekly production schedules. Combined with our 12-hour technical support, this comprehensive commercial framework makes our DC Cooling Fan systems the most reliable, cost-effective, and performance-proven thermal solutions on the global market today.
LOBISONG LBH1238 120x120x38mm DC Cooling Axial Fan

LOBISONG LBH1238 120x120x38mm DC Cooling Axial Fan

LOBISONG LBH1238 120x120x38mm DC axial fan for cabinet, server and power supply cooling; stable airflow, low noise, long service life.

LOBISONG LBMS1438 Series — 140×140×38mm DC Axial Fan

LOBISONG LBMS1438 Series — 140×140×38mm DC Axial Fan

LOBISONG LBMS1438 Series — 140×140×38mm DC Axial Fan

Product Overview

The LOBISONG LBMS1438 Series is a high-performance 140mm × 140mm × 38mm DC axial fan engineered for demanding thermal management applications. With a robust frame thickness of 38mm, this fan delivers superior static pressure and airflow compared to standard 25mm-thick alternatives, making it an ideal solution for servers, telecom cabinets, industrial inverters, and high-density electronic enclosures where reliable heat dissipation is critical.

Key Specifications

Parameter Specification
Frame Dimensions 140 × 140 × 38 mm
Rated Voltage 12 / 24 / 48 VDC (model-dependent)
Bearing Type Dual Ball Bearing
Speed Range 2,500 – 8,200 RPM
Max Airflow Up to 358.8 CFM
Max Static Pressure Up to 3.10 inch H₂O
Noise Level 29 – 77 dBA (speed-dependent)
Operating Temperature −10°C to +70°C
Expected Life 70,000 hours @ 40°C (L10)

Design & Features

The LBMS1438 Series incorporates an impeller and frame constructed from thermoplastic PBT UL94V-0 material, ensuring flame retardancy and dimensional stability under thermal stress. The ball bearing system provides reliable operation across a wide temperature range and supports any mounting orientation without the risk of lubricant migration associated with sleeve bearings.

Standard protective features include soft start (reducing inrush current at power-on), polarity protection (preventing damage from reversed supply connections), and auto-restart (automatic recovery after rotor lock removal). Optional functions such as tachometer output (FG), locked rotor alarm signal (RD), and PWM speed control enable system-level monitoring and dynamic thermal regulation.

Applications

  • Server and storage rack cooling

  • Telecom base station cabinets

  • Industrial inverters and power supplies

  • EV charging modules

  • Welding equipment and laser systems

  • HVAC air handling units

The LBMS1438 Series combines high airflow density, flexible voltage compatibility, and long service life, making it a dependable choice for engineers designing compact, high-reliability cooling systems.

LOBISONG LBMS1751-H Series 171mm x 153mm x 51mm DC Axial Fan

LOBISONG LBMS1751-H Series 171mm x 153mm x 51mm DC Axial Fan

The LOBISONG LBMS1751-H Series is a 171 x 153 x 51mm axial DC fan for installations that must tolerate water as well as heat. Running on 12V, 24V or 48V, the DC fan keeps an aluminium frame and a UL94V-0 PBT impeller, weighs 0.66 kg, and can be ordered with an IP68 protection option. 

LOBISONG LBMA1751 Series 172mm x 150mm x 51mm DC Axial Fan

LOBISONG LBMA1751 Series 172mm x 150mm x 51mm DC Axial Fan

The LOBISONG LBMA1751 Series is a high-performance 172mm x 150mm x 51mm DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this robust cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment.

LOBISONG LBMM1865 Series 180mm x 180mm x 65mm DC Axial Fan

LOBISONG LBMM1865 Series 180mm x 180mm x 65mm DC Axial Fan

The LOBISONG LBMM1865 Series is a robust 180mm x 180mm x 65mm DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment.

LOBISONG LBMH2060 Series 200mm x 200mm x 60mm DC Axial Fan

LOBISONG LBMH2060 Series 200mm x 200mm x 60mm DC Axial Fan

The LOBISONG LBMH2060 Series is a robust 200mm x 200mm x 60mm DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment

LOBISONG LBMM2072 Series 208mm x 208mm x 72mm DC Axial Fan

LOBISONG LBMM2072 Series 208mm x 208mm x 72mm DC Axial Fan

The LOBISONG LBMM2072 Series is a robust 208mm x 208mm x 72mm DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment.

LOBISONG LBMM2260 Series 222mm dia x 60mm DC Axial Fan

LOBISONG LBMM2260 Series 222mm dia x 60mm DC Axial Fan

The LOBISONG LBMM2260 Series is a high-performance 222mm diameter x 60mm thick DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this robust cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment.

LOBISONG LBMM2280 Series 222mm dia x 80mm DC Axial Fan

LOBISONG LBMM2280 Series 222mm dia x 80mm DC Axial Fan

The LOBISONG LBMM2280 Series is a high-performance 222mm diameter x 80mm thick DC axial fan, engineered for superior thermal management in demanding environments. Designed to deliver exceptional airflow and high static pressure, this robust cooling solution is ideal for telecom cabinets, servers, and heavy industrial equipment.

LOBISONG LBMM22580 Series 225mm x 225mm x 80mm DC Axial Fan

LOBISONG LBMM22580 Series 225mm x 225mm x 80mm DC Axial Fan

The LOBISONG LBMM22580 Series is a high-performance 225mm x 225mm x 80mm DC axial fan engineered for demanding thermal management. Designed to deliver superior airflow and high static pressure, this robust cooling solution is ideal for servers, telecom cabinets, and heavy industrial equipment.

LOBISONG LBMH2589 Series 254mm dia x 89mm DC Axial Fan

LOBISONG LBMH2589 Series 254mm dia x 89mm DC Axial Fan

The LOBISONG LBMH2589 Series is a rugged 254mm diameter × 89mm DC axial fan built for heavy-duty thermal management in industrial and commercial equipment. Combining a robust metal frame with a high-efficiency impeller, it delivers dependable high-volume airflow with long service life.

LOBISONG LBMM2589 Series 255mm dia x 89mm DC Axial Fan

LOBISONG LBMM2589 Series 255mm dia x 89mm DC Axial Fan

The LOBISONG LBmm2589 Series is a heavy-duty 255mm diameter × 89mm DC axial fan engineered for high-volume thermal management in demanding industrial environments. Built with a die-cast magnesium alloy frame and impeller, it delivers exceptional airflow and static pressure with reliable long-term operation.

LOBISONG LBMM28080 Series 280mm dia x 80mm DC Axial Fan

LOBISONG LBMM28080 Series 280mm dia x 80mm DC Axial Fan

The LOBISONG LBMM28080 Series is a high-performance 280×280×80mm DC axial fan engineered for demanding industrial thermal management. Combining a die-cast aluminum frame with precision dual ball bearings, it delivers reliable, high-volume airflow for the most challenging cooling environments.

LOBISONG DC Fan LB28080 280×280×80mm

LOBISONG DC Fan LB28080 280×280×80mm

The LOBISONG LB28080 is a large-format axial DC cooling fan engineered for demanding thermal management applications in industrial, telecommunications, and power electronics environments. Featuring a substantial 280×280×80mm frame, this fan delivers exceptional airflow performance while maintaining a compact depth profile suitable for space-constrained installations.

LOBISONG DC Fan LB25489-7 254×89mm

LOBISONG DC Fan LB25489-7 254×89mm

The LOBISONG LB25489-7 is a large-frame DC axial cooling fan measuring 254×254×89 mm, designed for high-volume thermal management in industrial and infrastructure applications. Available in 12V, 24V, and 48V DC configurations, it delivers airflow ranging from approximately 305 to 1,296 CFM depending on voltage and speed variant.

LOBISONG DC Fan LB22580 225×225×80mm

LOBISONG DC Fan LB22580 225×225×80mm

The LOBISONG LK22580 is a 225×225×80mm brushless DC axial fan built for extreme airflow and high static pressure. Its oversized impeller and deep 80mm frame move massive air through dense heatsinks, filters, and ducted enclosures, ideal for telecom cabinets, servers, power supplies, inverters, HVAC systems, and industrial control panels.

LOBISONG DC Fan LB22060 220×60mm

LOBISONG DC Fan LB22060 220×60mm

The LOBISONG LB22060 is a 220×60mm brushless DC axial fan engineered for high-volume airflow in large enclosures. Its oversized impeller and 60mm deep frame move air through dense heatsinks, filters, and ducted systems, ideal for telecom cabinets, servers, power supplies, inverters, HVAC equipment, and industrial control panels.

LOBISONG DC Fan LB20572 205×205×72mm

LOBISONG DC Fan LB20572 205×205×72mm

The LOBISONG LB20572 is a 205×205×72mm brushless DC axial fan built for maximum airflow and strong static pressure. Its oversized impeller and deep 72mm frame move massive air through dense heatsinks, filters, and ducted enclosures, ideal for telecom cabinets, servers, power supplies, inverters, HVAC, and industrial panels.