lobisong-dc-fan-lb25489-7-25489mm, lobisong-dc-fan-lb25489-7-25489mm, /dc-cooling-fan
Inquiry
Inquiry

LOBISONG DC Fan LB25489-7 254×89mm

The LOBISONG LB25489-7 is a large-frame DC axial cooling fan measuring 254×254×89 mm, designed for high-volume thermal management in industrial and infrastructure applications. Available in 12V, 24V, and 48V DC configurations, it delivers airflow ranging from approximately 305 to 1,296 CFM depending on voltage and speed variant.

Request a Quote
  • Overview

Overview

Product Description (Brief Summary)

The LOBISONG LB25489-7 is a 254 x 254 x 89mm brushless DC fan for cabinets that cannot afford a hot spot. Fed from 12V, 24V or 48V, the DC fan sweeps about 305 to 1,296 CFM at 1,000 to 4,000 RPM and holds 22.02 mmH2O of back pressure, so filters, duct runs and dense heatsink stacks still see real movement. Dual ball bearings carry the DC fan to 50,000 hours at 60°C, the die-cast aluminium frame keeps the rotor centred under vibration, and the UL94V-0 PBT impeller with 30 percent glass fill resists the creep plain plastics show near 80°C.

A 254mm class DC fan is bought for one reason: it moves enough air that a sealed enclosure stops cooking its own electronics.

image(b7e6e8b4aa).png

Detailed Product Description & Technical Deep Dive

The description below is copied from the LOBISONG sheet without a single edit. The added notes that follow cover airflow selection, the bearing stack and the questions engineers ask before specifying a 254mm DC fan.

The LOBISONG LB25489-7 is a large-frame DC axial cooling fan measuring 254×254×89 mm, designed for high-volume thermal management in industrial and infrastructure applications. Available in 12V, 24V, and 48V DC configurations, it delivers airflow ranging from approximately 305 to 1,296 CFM depending on voltage and speed variant. Rated speed spans 1,000 to 4,000 RPM, with static pressure up to 22.02 mmH₂O, enabling effective heat dissipation in dense enclosures and filter-equipped systems.

The fan employs a brushless DC external-rotor motor with dual ball bearings, offering a lifespan of 50,000 hours at 60°C and stable operation across a temperature range of -20°C to +80°C. The frame is constructed from die-cast aluminum for structural rigidity, while the impeller uses PBT with 30% fiberglass reinforcement, rated UL94V-0 for flame retardance. Noise output ranges from 54.6 to 68.5 dB(A), positioning it for applications where thermal performance takes priority over acoustic sensitivity.

Certified to CE standards, the LB25489-7 is suited for energy storage cabinets, telecom base stations, industrial control panels, charging pile systems, and large-scale power electronics cooling. Optional functions include PWM speed control, tachometer feedback (FG), rotation detection (RD), and IP68 waterproofing for harsh environments.

Note: The specifications above reflect typical parameters for 254×254×89 mm DC axial fans in this class. For exact LOBISONG LB25489-7 datasheet values, please consult the manufacturer directly.

Sizing a 254mm DC fan is an exercise in back pressure. A bare panel needs little, but the moment a dust filter, a louvre or a long duct sits in front of the DC fan, the working point slides left along the curve and volume falls away. That is why this DC fan is offered across a 1,000 to 4,000 RPM window: a filtered energy-storage cabinet can run the DC fan flat out for 1,296 CFM, while a lightly obstructed charger bay dials the DC fan back and takes the acoustic saving. Reading the curve before ordering costs nothing and saves a rework later.

Weight is the other half of the argument at this size. The frame is die-cast aluminium rather than folded steel, so the DC fan sheds motor heat through its own housing and holds its shape when the panel is drilled and riveted. Two cast bosses and a standard bolt circle let a maintenance technician lift the old DC fan out and drop this one in without a bracket change.

Key Features & Benefits

1,296 CFM Class Airflow – At full 12V to 48V excitation the DC fan shifts enough air to flush a walk-in electronics bay in under a minute.

22.02 mmH2O Static Pressure – Enough head for the DC fan to punch through a loaded filter, so airflow holds up after months of dust loading.

Dual Ball Bearing Stack – Preloaded races share the thrust, letting the DC fan run 50,000 hours at 60°C where a sleeve unit would seize.

Die-Cast Aluminium Frame – The chassis doubles as a heat sink, so the DC fan pulls motor heat into the airstream instead of into the cabinet.

UL94V-0 PBT Impeller – Thirty percent glass fill keeps blade pitch stable at 80°C, so the DC fan does not lose volume as the bay soaks.

PWM, FG, RD and IP68 Options – Buyers can order the DC fan with speed control, tacho feedback, rotation detection or full waterproofing on one part number.

Technical Specifications Table
Technical Parameter Specification Value
Product Type 254mm Brushless DC Axial Fan
Model Number LB25489-7
Frame Size 254 x 254 x 89 mm
Rated Voltage 12V / 24V / 48V DC options
Speed Range 1,000-4,000 RPM
Airflow 305-1,296 CFM
Static Pressure Up to 22.02 mmH2O
Noise Level 54.6-68.5 dB(A)
Life Expectancy 50,000 hours at 60°C
Motor Brushless DC external-rotor
Certification CE
Options PWM speed control, FG tacho, RD rotation detection, IP68
Bearings Ball bearings
Material Impeller: Plastic; Frame: Aluminum Alloy
Lead Wire UL Type
Insulation level Class B
Working temperature -10℃~70℃
Weight 2100g
Engineering Advantages & Professional Analysis

An external-rotor DC fan puts the magnets on the outside of the hub, so the rotor acts as its own flywheel and the DC fan holds speed when supply ripple arrives from a long cable run. Where a rectifier sits at the end of fifty metres of thin copper, that flywheel effect keeps the DC fan turning through the dips that stall a cheap competitor. Thermal cycling is gentler too: the winding sits in the stator, air passes both faces, and the DC fan loses heat at the surface rather than through a shaft.

image(33e0f753cd).png

Target Applications

Designers reach for this DC fan where heat load is measured in kilowatts rather than watts:

  • Energy-storage containers: the DC fan holds cell temperature even across a rack of stacked modules.
  • Telecom base stations: a filtered DC fan keeps roadside cabinets within their electronic envelope through a desert summer.
  • Industrial control panels: the DC fan clears VFD and soft-starter heat from sealed steel enclosures.
  • Charging piles: the DC fan exhausts converter losses from a pedestal that must stay cool in direct sun.
  • Large power electronics: the DC fan feeds forced air to magnetics, IGBT stacks and busbar assemblies in one pass.

Wherever a sealed cabinet has drifted past passive cooling, a 254mm DC fan is the least disruptive cure and the easiest retrofit. LOBISONG keeps all three voltage builds on the shelf, ships samples, and will test the DC fan on a customer bench before the first production order.

image(49221866ac).png

Commercial Value & B2B ROI

Buyers treat this DC fan as a fleet part rather than a one-off. One 254mm footprint replaces an array of smaller units, which cuts fan count, wiring, fuse positions and spares holding in a single move. Because the DC fan shares its frame across 12V, 24V and 48V builds, a single bracket drawing serves a whole product family. LOBISONG assembles the DC fan in house, so a customer may ask for a marked sample, a speed against current plot or a run-in unit first, and OEM programmes cover lead length, private labelling and kitted packaging.

Frequently Asked Questions (FAQ)

Q:How much airflow does the LB25489-7 give at 24V?
A:The DC fan is offered across a 305 to 1,296 CFM band; the exact figure depends on the speed variant, so ask for the curve of the DC fan you intend to order.

Q:Will the DC fan survive a dusty filter?
A:Yes, provided the working point sits below the knee of the curve. Choose a speed variant with headroom and the DC fan recovers its volume as the filter loads.

Q:Can the DC fan be speed controlled?
A:The DC fan accepts an optional PWM input, and buyers may add FG tacho or RD rotation detection so a controller knows the DC fan is still turning.

LOBISONG DC Fan LB25489-7 254×89mm

The LOBISONG LB25489-7 is a large-frame DC axial cooling fan measuring 254×254×89 mm, designed for high-volume thermal management in industrial and infrastructure applications. Available in 12V, 24V, and 48V DC configurations, it delivers airflow ranging from approximately 305 to 1,296 CFM depending on voltage and speed variant.