The LOBISONG LB28080 is a large-format axial DC cooling fan engineered for demanding thermal management applications in industrial, telecommunications, and power electronics environments. Featuring a substantial 280×280×80mm frame, this fan delivers exceptional airflow performance while maintaining a compact depth profile suitable for space-constrained installations.
The LOBISONG LB28080 is a 280 x 280 x 80mm axial DC fan for cabinets where heat load runs into kilowatts. On a 24V rail the DC fan reaches about 1,100 CFM at 3,000 RPM against 31.15 mmH2O and draws roughly 72W, so one DC fan replaces a row of smaller units. Dual ball bearings rate the DC fan at 85,000 hours L10, and the die-cast aluminium frame keeps the DC fan stiff under vibration.

Everything between the headings below is the LB28080 text from the LOBISONG sheet, reproduced without a single edit, followed by notes on selecting this DC fan.
LOBISONG DC Fan LB28080 — 280×280×80mm High-Performance Axial Cooling Fan
Product Overview
The LOBISONG LB28080 is a large-format axial DC cooling fan engineered for demanding thermal management applications in industrial, telecommunications, and power electronics environments. Featuring a substantial 280×280×80mm frame, this fan delivers exceptional airflow performance while maintaining a compact depth profile suitable for space-constrained installations. LOBISONG has established itself as a trusted supplier of cooling solutions for motor drives, compression equipment, and grain handling systems, and the LB28080 represents the company's commitment to reliable, high-volume air movement for critical equipment protection.
Technical Specifications
The LB28080 operates on DC power with available voltage options spanning 12V, 24V, and 48V configurations, accommodating diverse system architectures. At its rated 24V operating point, the fan achieves a maximum airflow of approximately 1,100 CFM (cubic feet per minute) at a rated speed of 3,000 RPM, generating maximum static pressure of 31.15 mmH₂O. Power consumption is rated at 72W, delivering an excellent balance between cooling capacity and energy efficiency. The fan employs a brushless DC external rotor motor with auto-cutoff and auto-restart protection, ensuring safe operation under abnormal conditions including locked rotor events and reverse polarity connection.
The frame is constructed from die-cast aluminum with a natural finish, providing structural rigidity and effective heat dissipation from the motor assembly. The impeller is manufactured from PBT UL94 V-0 reinforced plastic, meeting stringent flammability standards for industrial equipment. The fan supports an operating temperature range of -20°C to +65°C, with storage tolerance extending to +75°C, making it suitable for deployment in harsh environmental conditions.
Performance Features
The LB28080 incorporates a dual ball bearing system rated for 85,000 hours of L10 life expectancy at 35°C ambient temperature, ensuring long-term reliability with minimal maintenance requirements. The fan is available with optional PWM speed control input, thermal speed control, tachometer output, and alarm output, enabling integration with intelligent thermal management systems that adjust cooling capacity based on real-time temperature feedback. Electrical safety is assured through 500VDC/min dielectric strength testing and insulation resistance exceeding 10MΩ at 500VDC.
Applications
The LB28080 is purpose-built for high-heat industrial scenarios requiring forced-air cooling. Typical applications include variable frequency drive (VFD) cabinets, telecommunications base station equipment, industrial power supplies, welding machines, and large-scale LED lighting arrays. The fan's substantial airflow capacity makes it particularly effective in tunnel ventilation systems and equipment racks where multiple heat-generating components require simultaneous cooling.
Quality and Compliance
LOBISONG cooling fans are manufactured under strict quality control protocols consistent with ISO9001 and ISO14001 standards. The LB28080 meets CE and UL certification requirements, with EMC compliance to EN 61000-6-3 and EN 61000-4 series standards. Each unit undergoes comprehensive testing including visual inspection, leak testing, and safety verification before shipment.
Conclusion
The LOBISONG LB28080 combines high airflow output, robust construction, and intelligent control options in a compact 280×280×80mm form factor. With its extended service life, wide voltage compatibility, and comprehensive protection features, it represents a dependable thermal management solution for engineers designing cooling systems for demanding industrial and commercial applications.
A DC fan this size is chosen for headroom. Where a 120mm unit would run at its ceiling and howl, this DC fan does the same duty far down its curve, so the DC fan stays quiet and the cabinet keeps margin for extra load. The 80mm depth is deliberate too, since the DC fan still fits a plenum or a door louvre without a standoff.
Auto-cutoff trips when the rotor of the DC fan stalls, auto-restart brings the DC fan back once the obstruction clears, and reverse polarity leaves the DC fan unharmed. Optional PWM and alarm outputs let a controller trim the DC fan against a real temperature reading.
1,100 CFM at 3,000 RPM – One DC fan clears a full-height VFD cabinet that once needed several blowers.
72W at the Rated Point – Moved air per watt is the reason to pick a large DC fan over a bank of small ones.
85,000 Hour Bearings – L10 rated at 35°C, the DC fan outlasts the electrolytics beside it.
Auto-Cutoff and Restart – A stalled rotor stops the DC fan instead of cooking it.
Die-Cast Aluminium Frame – The alloy chassis gives the DC fan rigidity and sheds motor heat into the airstream.
Certified and Tested – CE and UL requirements, with EMC to EN 61000-6-3, back every DC fan that ships.
| Technical Parameter | Specification Value |
| Product Type | 280mm Axial DC Cooling Fan |
| Model Number | LB28080 |
| Frame Size | 280 x 280 x 80 mm |
| Rated Voltage | 12V / 24V / 48V DC options |
| Rated Speed | 3,000 RPM (24V reference point) |
| Max Airflow | About 1,100 CFM |
| Max Static Pressure | 31.15 mmH2O |
| Power Consumption | 72W |
| Noise Level | Large-frame industrial class |
| Life Expectancy | 85,000 hours L10 at 35°C |
| Motor Protection | Auto-cutoff, auto-restart, reverse polarity |
| Options | PWM, thermal speed control, tacho, alarm output |
| Bearings | Ball bearings |
| Material | Impeller: Plastic; Frame: Aluminum Alloy |
| Lead Wire | UL Type |
| Insulation level | Class B |
| Working temperature | -10℃~70℃ |
| Weight | 2400g |
Back pressure decides whether a large DC fan earns its keep. Read the plot at the duty point rather than at free air: the 31.15 mmH2O ceiling is the reserve the DC fan keeps for a clogged filter, and that reserve is what stops cabinet temperature creeping up between service visits.

This DC fan suits high-heat industrial work:
LOBISONG stocks the voltage builds, sends samples and tests the DC fan on request before a production order.

Procurement sees it as arithmetic: fewer DC fans to buy, fewer holes to punch, fewer spares to hold. One frame covers the range, so a single position serves every product built around this DC fan. LOBISONG assembles the DC fan in house and keeps OEM terms open on labels and packaging.
Q:Is 1,100 CFM measured at free air?
A:Yes, that is the ceiling for the DC fan. Real cabinets sit lower, so match the duty point to the plot first.
Q:Which bearing suits continuous duty?
A:The dual ball stack is standard, and it is the right choice wherever the DC fan runs at elevated temperature.
Q:Can the DC fan report a failure?
A:An optional alarm or tacho output tells the controller the DC fan has stopped, turning a hidden fault into an alert.
The LOBISONG LB28080 is a large-format axial DC cooling fan engineered for demanding thermal management applications in industrial, telecommunications, and power electronics environments. Featuring a substantial 280×280×80mm frame, this fan delivers exceptional airflow performance while maintaining a compact depth profile suitable for space-constrained installations.