DC Cooling Fan

In the high-stakes world of modern industrial electronics and telecommunications, a single micro-degree of heat buildup can trigger catastrophic system downtime. Our high-performance DC Cooling Fan systems deliver precise, dynamic, and energy-efficient thermal regulation, ensuring your critical hardware runs at peak performance under the most grueling continuous workloads.   Engineered for intelligent, low-power, and ultra-reliable thermal management, our industrial-grade DC Cooling Fan models provide the ultimate protection for heat-sensitive electronics with smart speed control and a proven 98% on-time global delivery guarantee.   Smart PWM Speed Control & Low Power Consumption: By utilizing advanced brushless DC motor technology, each DC Cooling Fan dynamically adjusts its rotational speed based on real-time system temperatures. This precise modulation reduces power consumption by up to 30% compared to traditional fans, significantly lowering your operational costs and extending the lifespan of your internal electronic components. Custom-Engineered IP56/IP68 Environmental Protection:   Moisture, dust, and corrosive gases are the silent killers of industrial hardware. We develop tailor-made DC Cooling Fan solutions featuring specialized conformal coatings and fully sealed motor housings, ensuring uninterrupted airflow and rugged durability even in the harshest marine, agricultural, or outdoor telecommunication environments. Flexible Tier-Based Volume Discounts:   Budget predictability is vital for your long-term project planning. We provide transparent, tier-based discounts according to your order quantities, allowing procurement managers to secure premium-quality DC Cooling Fan units at highly competitive unit prices while maximizing return on investment for large-scale industrial rollouts. 24/7 Global Technical Support & Fault Diagnosis:   Technical issues do not follow a standard 9-to-5 schedule. Our expert engineering team offers round-the-clock online guidance and advanced fault diagnosis for DC Cooling Fan integration, helping partners across Europe, Russia, India, and the Americas resolve complex cooling challenges in under 12 hours.   Don't let thermal bottlenecks compromise your equipment's lifespan—contact our engineering team today to customize your high-volume DC Cooling Fan solution and secure your project's exclusive volume discount!     Industrial Automation & Renewable Energy Integration The modern industrial landscape demands unprecedented levels of power density. Within server racks, solar inverters, and automated control cabinets, the heat generated by high-frequency switching transistors must be evacuated immediately. A standard thermal solution is no longer sufficient. Our specialized DC Cooling Fan series is engineered specifically to address these high-static-pressure requirements. By optimizing the blade aerodynamics through extensive computational fluid dynamics (CFD) testing, we have created a DC Cooling Fan blade profile that maximizes volumetric airflow while minimizing localized turbulence.   This advanced aerodynamic profile ensures that even in densely packed electronic enclosures where airflow impedance is extremely high, the DC Cooling Fan maintains a consistent, laminar stream of cooling air. This level of thermal reliability is why leading industrial automation partners from Europe to the Americas trust our DC Cooling Fan products to safeguard their multi-million dollar production lines.   Tailor-Made Engineering & Structural Adaptability No two industrial projects are identical. A DC Cooling Fan that works perfectly in a well-ventilated server room will fail rapidly in a dusty mining control panel or a humid coastal wind turbine. Recognizing this reality, our dedicated R&D division prioritizes Custom Engineering. We do not merely sell off-the-shelf products; we collaborate closely with your technical teams to modify the physical and electrical parameters of each DC Cooling Fan.   Whether your project requires custom lead wire lengths, specialized connector terminals, auto-restart protection, locked-rotor alarm signals (RD), or tachometer frequency generator outputs (FG), our custom engineering services adapt the DC Cooling Fan to integrate seamlessly with your proprietary control systems. This bespoke approach eliminates the need for costly retrofitting and accelerates your product's time-to-market.   Global Supply Chain Resilience & Maintenance Support In a globalized manufacturing economy, supply chain delays can halt entire assembly operations. We combat this volatility by maintaining a highly automated manufacturing facility that guarantees a 98% on-time delivery rate. When you integrate our DC Cooling Fan into your long-term production schedule, you are backed by a robust supply chain that utilizes advanced inventory forecasting.   Furthermore, our commitment to our partners extends far beyond the initial purchase. We actively support your operational continuity through our Genuine Spare Parts Supply. Original DC Cooling Fan blades, long-life ball bearings, and specialized motor components are constantly kept in stock and prepared for rapid global shipment. To ensure your local technicians can maximize the operational life of your cooling systems, we also offer comprehensive Maintenance & Technical Training programs, providing your staff with the technical expertise needed for routine overhauls and system optimizations.   Advanced Brushless DC Motor Engineering The beating heart of our DC Cooling Fan is the highly optimized brushless DC (BLDC) motor. Traditional brushed motors suffer from mechanical wear, frictional heat, and electromagnetic interference (EMI) due to constant brush-commutator contact. Our brushless DC Cooling Fan design entirely eliminates these vulnerabilities. By utilizing solid-state electronic commutation and premium permanent NdFeB (Neodymium Iron Boron) magnets, our DC Cooling Fan achieves exceptionally high magnetic flux density. This results in superior mechanical efficiency and a massive reduction in internal thermal losses. Furthermore, the electronic components of the DC Cooling Fan motor drive are isolated from the mechanical structure using high-grade, heat-conductive epoxy encapsulation. This ensures that the delicate driver ICs remain cool, preventing premature electrical degradation even during continuous 24/7 duty cycles.   Dynamic Balancing and Rotor Alignment Protocols Every single DC Cooling Fan assembly is subjected to a state-of-the-art, two-plane dynamic balancing process prior to final packaging. Micro-vibrations in a high-speed DC Cooling Fan can lead to rapid bearing wear, localized structural noise, and eventual fan failure. Our automated balancing machinery measures rotational imbalance down to the milligram level. Specialized counterweights are permanently applied to the inner rim of the DC Cooling Fan impeller to correct any non-concentric weight distribution. This meticulous alignment guarantees that the DC Cooling Fan operates with a vibration amplitude of less than 0.05 mm/s. By maintaining such strict tolerance limits, we minimize the radial and axial loads placed on our premium Japanese NMB ball bearings, allowing the DC Cooling Fan to easily achieve an L10 life expectancy exceeding 70,000 hours at 40°C.    Strategic Procurement Optimization for Industrial Projects Selecting the ideal thermal management system is not only a technical decision but also a critical financial strategy. When designing large-scale infrastructure, telecom networks, or medical imaging equipment, the long-term total cost of ownership (TCO) must be strictly managed. Our tier-based pricing structure is specifically structured to assist procurement departments in achieving significant cost savings. By locking in long-term bulk agreements for a specific DC Cooling Fan model, your organization secures a highly stable unit price, completely insulated from seasonal material cost fluctuations. Our logistics team integrates seamlessly with your enterprise resource planning (ERP) systems, offering Just-In-Time (JIT) deliveries that align with your weekly production schedules. Combined with our 12-hour technical support, this comprehensive commercial framework makes our DC Cooling Fan systems the most reliable, cost-effective, and performance-proven thermal solutions on the global market today.
LOBISONG LBG8020 Series
80mm x 80mm x 20mm
DC Axial Fan

LOBISONG LBG8020 Series 80mm x 80mm x 20mm DC Axial Fan

The LOBISONG LBG8020 Series is an 80mm × 80mm × 20mm DC axial fan line built for slim-profile thermal management where the standard 25mm thickness will not fit. While a model-specific LOBISONG datasheet for the LBG prefix is not publicly indexed, the 8020 platform shares well-defined performance and construction conventions across the industry that define its operating envelope.

Performance range. Typical 8020 fans run from roughly 2,000 RPM to 4,000 RPM, producing airflow in the 22 CFM to 49 CFM range and static pressure from about 1.3 to 5.2 mmH₂O. Noise scales from a quiet ~22 dBA at the low-speed end to around 37 dBA at maximum speed. Nominal voltage options commonly include 5 VDC, 12 VDC, and 24 VDC, with some variants extending to 48 VDC. For reference, a representative mid-speed 12 VDC unit delivers approximately 38 CFM at 3,000 RPM and 29 dBA, while a low-speed sleeve-bearing version can drop to around 25 CFM and 23.6 dBA.

Construction and bearing options. Housings and impellers are molded from UL94V-0 rated PBT thermoplastic, with ribbed frame designs for structural rigidity. Bearing choices span sleeve bearing, ball bearing (single or dual), and in some lines fluid dynamic bearing, allowing a trade-off between cost, service life, and mounting orientation. Lead wires are typically AWG 26 UL1007 style, and optional tachometer output, locked-rotor alarm, and PWM speed control are commonly offered for system-level thermal regulation. The 20mm depth is the defining constraint of this series, trading a modest reduction in airflow capacity against the 25mm standard in exchange for space savings in dense enclosures.

Typical applications. The 80×80×20 mm footprint suits low-profile power supplies, 1U/2U rack equipment, thin-client and set-top electronics, LED drivers, and compact industrial controllers where vertical clearance is limited. It is also a common choice for retrofit cooling in legacy equipment originally designed around 20mm-thick fans, and for prototyping and custom enclosures where every millimeter of internal height matters.

LOBISONG LBF8025 Series
80mm x 80mm x 25mm
DC Axial Fan

LOBISONG LBF8025 Series 80mm x 80mm x 25mm DC Axial Fan

The LOBISONG LBF8025 Series is a line of 80mm × 80mm × 25mm DC axial fans positioned for cost-effective, general-purpose cooling in compact electronic and industrial enclosures. While LOBISONG-specific datasheets for the LBF prefix are not widely published, the series shares the standard 8025 platform specifications common to this fan class.

Performance range. Typical 8025 fans span speeds from approximately 2,000 RPM to 6,000 RPM, with airflow ranging from roughly 25.6 CFM to 76.87 CFM and static pressure from about 1.60 to 14.29 mmAq. Noise output scales accordingly, from a quiet 22.0 dBA at the low end up to approximately 48 dBA at maximum speed. Standard voltage options include 5 VDC, 12 VDC, and 24 VDC, with 48 VDC variants available in the broader 8025 category.

Construction and bearing options. Frames and impellers are molded from PBT thermoplastic (often UL94V-0 rated for flame retardancy). Bearing choices typically include sleeve bearing, hydraulic bearing, and dual ball bearing, with sleeve bearings offering roughly 25,000 hours of life and ball-bearing versions reaching 50,000 hours or more. Lead wires are commonly UL2468 AWG #26 or equivalent, with red positive and black negative conductors. Operating temperature is generally rated from −10 °C to +70 °C.

Typical applications. The 80×80×25 mm form factor makes the LBF8025 series suitable for power supplies, control cabinets, 3D printer electronics, battery chargers, and general OEM equipment cooling. Optional FG tach signal and PWM speed control are frequently available for system-level thermal regulation.

LOBISONG LBMR8025 Series
80mm x 80mm x 25mm
DC Axial Fan

LOBISONG LBMR8025 Series 80mm x 80mm x 25mm DC Axial Fan

The LOBISONG LBMR8025 Series is a family of 80mm × 80mm × 25mm DC axial fans engineered for space-constrained thermal management where dependable, continuous airflow is required. Built around a brushless DC external-rotor motor, the series is available in 12 VDC and 24 VDC configurations to suit common industrial and electronics power rails.

Performance range. Typical operating speeds span roughly 3,000 RPM to 6,000 RPM, producing airflow between 39.67 and 76.87 CFM with static pressure from 3.80 to 14.29 mmAq. Acoustic noise across this range is rated at 32.2 to 48.60 dBA, depending on the speed variant selected. For a representative mid-range point, a 24 VDC unit running at 3,000 RPM delivers approximately 40 CFM at a low 27 dBA noise level.

Construction and bearing options. The frame and impeller are molded from PBT for dimensional stability and resistance to elevated temperatures. Bearing choices include dual ball bearing, long-life sleeve, and FDB (Fluid Dynamic Bearing) systems, allowing users to balance service life against cost and orientation sensitivity. The fans are rated for operation from −10 °C to +70 °C.

Typical applications. The 80×80×25 mm footprint makes the LBMR8025 series suitable for inverters, welders, power supplies, 3D printer electronics, custom enclosures, and general industrial cabinet cooling. With its brushless motor design, the series supports long-duration operation with low maintenance and is commonly supplied with 2-wire leads or JST-style connectors for drop-in installation.

LOBISONG LBMS8025 Series
80mm x 80mm x 25mm
DC Axial Fan

LOBISONG LBMS8025 Series 80mm x 80mm x 25mm DC Axial Fan

LOBISONG LBMS8025 Series: 80×80×25 mm DC axial fan available in 5 V, 12 V, 24 V, and 48 V options, with speed grades commonly spanning roughly 2,000 to 7,200 RPM depending on the selected variant. Typical performance in the 8025 footprint ranges from about 31 CFM to 72 CFM, with noise levels between approximately 28 dBA and 57 dBA across the speed spectrum. The slim 25 mm profile makes the LBMS8025 a natural fit for space-constrained enclosures where depth is limited but forced convection is still required—including computer chassis, power supplies, AV equipment, 3D printers, and compact industrial controllers. Bearing options across this series typically include sleeve, dual ball, and hydraulic bearings, with housing and impeller molded from UL94V-0 flame-retardant plastic. Supported features commonly include PWM speed control, FG tachometer output, and optional locked-rotor or rotational-detection signals, with 2-pin, 3-pin, and 4-pin connector configurations available. Lower-speed variants prioritize quiet operation for consumer and office environments, while higher-speed models deliver maximum airflow within the 80×25 mm envelope for denser thermal loads. Verify the exact LBMS8025 sub-model code for voltage, bearing type, speed grade, and control configuration against LOBISONG's official datasheet before finalizing, as specifications vary by variant.

LOBISONG LBG8032 Series
80mm x 80mm x 32mm
DC Axial Fan

LOBISONG LBG8032 Series 80mm x 80mm x 32mm DC Axial Fan

LOBISONG LBG8032 Series: 80×80×32 mm DC axial fan offered in 12 V, 24 V, and 48 V options, with speed grades spanning roughly 3,500 RPM to 6,500 RPM to match different airflow and acoustic targets. Typical performance in this footprint ranges from about 43 CFM to 80 CFM, with noise levels between approximately 47.7 dBA and 58 dBA depending on the selected speed variant. The 32 mm depth provides a useful middle ground between slim 25 mm fans and high-pressure 38 mm designs, making the LBG8032 suitable for industrial control cabinets, laboratory equipment, telecom enclosures, and electronics cooling where moderate static pressure is required without excessive bulk. Construction typically uses PBT UL94V-0 plastic or aluminum alloy for flame resistance and durability, with dual ball bearing or sleeve bearing options available across the series. Supported features commonly include PWM speed control, FG tachometer output, polarity protection, and locked-rotor protection, with CE, FCC, RoHS, and ISO:9001 certifications typical for this class. Operating temperature is rated around −10 °C to 70 °C. Select a lower-speed variant for quieter operation or a higher-speed model for maximum cooling within the 80×32 mm envelope. Verify the exact LBG8032 sub-model code for voltage, bearing type, and control configuration with the manufacturer's datasheet before finalizing, as specifications vary by variant.

LOBISONG LBMR8032 Series
80mm x 80mm x 32mm
DC Axial Fan

LOBISONG LBMR8032 Series 80mm x 80mm x 32mm DC Axial Fan

LOBISONG LBMR8032 Series: 80×80×32 mm DC axial fan available in 12 V or 24 V, offered in four speed grades—L, M, H, and E—to match airflow and noise requirements. The series spans roughly 61 CFM at 41.6 dBA (5,000 RPM) up to 79 CFM at 50.4 dBA (6,500 RPM), with maximum static pressure rising from 1.72 to 2.23 in H₂O across the range. The 32 mm depth provides a middle ground between slim 25 mm fans and high-pressure 38 mm designs, making it suitable for electronics, telecom gear, and industrial enclosures where moderate pressure capability is needed without the bulk of a deeper fan. Construction uses UL94V-0 plastic impeller and frame, with ball bearing or sleeve bearing options depending on the variant. Available features include tachometer output, locked-rotor alarm, PWM speed control, soft start, polarity protection, and auto-restart. The series carries CE, cUL, TUV, and UL approvals, and weighs approximately 145 g. Select the L model for quiet operation, M for balanced performance, H for higher airflow, or E for maximum cooling in this footprint. Verify the exact LBMR8032 sub-model code for your voltage, bearing, and control configuration before finalizing.

LOBISONG LBMC8038 Series
80mm x 80mm x 38mm
DC Axial Fan

LOBISONG LBMC8038 Series 80mm x 80mm x 38mm DC Axial Fan

LOBISONG LBMC8038 Series: 80×80×38mm DC axial fan. 12V/24V, dual ball bearing, ~5500 RPM, 72 CFM, 51 dBA, 50,000 hrs, PWM optional.

This compact 80mm fan delivers a strong balance of high airflow and static pressure within a 38mm deep frame, making it suitable for dense electronics, telecom equipment, and industrial enclosures where space is constrained. The dual ball bearing construction supports a rated life of approximately 50,000 hours, while the ~5500 RPM speed class puts it in the high-performance tier for this footprint. With a noise level around 51 dBA and airflow near 72 CFM, it targets applications that need forceful cooling without crossing into the loudest end of the 80×38mm spectrum. PWM and tachometer options are commonly available in this format for speed control and monitoring.

LOBISONG LBMS8038 Series
80mm x 80mm x 38mm
DC Axial Fan

LOBISONG LBMS8038 Series 80mm x 80mm x 38mm DC Axial Fan

The LOBISONG LBMS8038 Series is an 80 × 80 × 38 mm DC axial fan platform that inherits the core engineering premise of the 8038 form factor: 38 mm of depth is spent on pressure, not cosmetics. Where a 25 mm fan trades thickness for fit, the LBMS8038 uses the extra volume for a deeper blade section and a stronger motor, positioning it for thermal paths where backpressure rises faster than open-vent airflow falls.

Across the 8038 platform, configurations span 12 V, 24 V, and 48 V DC, with speed grades from roughly 3,500 RPM to beyond 9,000 RPM in documented variants; representative platform data show airflow ranging from approximately 98 m³/h at the low-speed end to over 180 m³/h at higher grades, with static pressure capability reaching 130–300 Pa in mainstream configurations and climbing substantially in high-output versions. Dual ball bearing construction is the standard specification for continuous-duty operation, while PWM speed control, FG tachometer output, and locked-rotor auto-restart can be specified for closed-loop thermal management. Note that the “MS8038” designation appearing in distribution channels belongs to Mechatronics, not LOBISONG; LBMS8038-specific ratings should be confirmed against LOBISONG’s own selection table for the exact SKU.

With operating temperature commonly rated to −10 °C to +70 °C, the LBMS8038 suits inverters, energy-storage enclosures, telecom chassis, industrial drives, and instrumentation where an 80 mm mounting pattern must still generate meaningful pressure against filters, fins, or ducted paths. Where the LBE9225 and LBMB9220 optimize for fit, the LBMS8038 is selected when the cooling problem is pressure head under constraint.

LOBISONG LBMR8038 Series
80mm x 80mm x 38mm
DC Axial Fan

LOBISONG LBMR8038 Series 80mm x 80mm x 38mm DC Axial Fan

The LOBISONG LBMR8038 Series is an 80 × 80 × 38 mm DC axial fan platform where the defining dimension is depth: the 38 mm thickness accommodates a wider blade section and a stronger motor than 25 mm or 20 mm fans of the same 80 mm footprint, making this series a static-pressure-first solution rather than a slim-fit compromise。In the 8038 class, the governing thermal problem is rarely open-vent airflow; it is moving air through dense heatsink fins, filter media, ducted paths, and crowded chassis interiors where backpressure rises quickly。

Across the 8038 platform, configurations commonly span 12 V, 24 V, and 48 V DC, with mainstream speed grades from roughly 3,400 RPM to 6,000 RPM and high-output variants reaching 8,000–15,000 RPM depending on the selected SKU。In the mainstream band, airflow typically lands between 45 CFM and 77 CFM, with noise tracking from approximately 39 dBA to 50 dBA。The series' advantage is static pressure: representative 8038 models deliver capabilities spanning roughly 7 mmH₂O at the low-speed end to 18–25 mmH₂O at higher speed grades, with high-speed industrial versions pushing considerably further。Dual ball bearing construction is the usual specification for continuous-duty operation, commonly rated for 50,000 hours, while sleeve bearing remains available for cost-sensitive or lower-duty designs。

The LBMR8038 is offered as a configurable platform, not a fixed SKU. PWM speed control, FG tachometer output, locked-rotor alarm, and auto-restart protection can be specified to support closed-loop thermal management and fault detection。Frame and impeller materials follow the 8038 convention of UL94V-0-rated PBT or die-cast aluminum, and some industrial variants extend protection to IP54 through IP68 for dust- and moisture-exposed installations。With operating temperature ranges commonly reaching −10 °C to +70 °C, the LBMR8038 suits power inverters, telecom and server chassis, industrial drives, welding equipment, and medical or instrumentation enclosures where an 80 mm mounting pattern must still overcome meaningful system impedance。Where the LBE9225 and LBMB9220 trade depth for fit, the LOBISONG LBMR8038 trades depth for pressure and thermal headroom under backpressure。

LOBISONG LBA8038 Series
80mm x 80mm x 38mm
DC Axial Fan

LOBISONG LBA8038 Series 80mm x 80mm x 38mm DC Axial Fan

The LOBISONG LBA8038 Series is an 80 × 80 × 38 mm DC axial fan platform defined by its 38 mm depth—a thickness that separates it from standard 25 mm and 20 mm fans by prioritizing static pressure and airflow density over slim-profile integration. In the 8038 class, the extra depth accommodates a wider blade section and a more powerful motor, making this series the appropriate choice when the cooling challenge is not open-vent airflow but pushing air through restrictive paths: dense heatsink fins, filter media, ducted channels, and crowded chassis interiors.

Across the 8038 platform, configurations commonly span 12 V, 24 V, and 48 V DC, with speed grades stretching from roughly 2,500 RPM to 5,500 RPM in mainstream variants and reaching substantially higher in high-speed industrial versions. In the mainstream range, airflow typically lands between 38 CFM and 73 CFM, with noise tracking from about 32 dBA to 51 dBA depending on the selected speed grade. Static pressure is the defining advantage: representative 8038 models deliver pressure capabilities in the 7–15 mmH₂O range at moderate speeds, and considerably higher in high-output configurations. Dual ball bearing construction is the standard choice for long-duty operation, commonly rated for 50,000 hours, while sleeve bearing options remain available for cost-sensitive, lower-duty designs.

The LBA8038 is offered as a configurable platform rather than a fixed SKU. PWM speed control, FG tachometer output, rotation alarm, and auto-restart locked-rotor protection can be specified to support closed-loop thermal management and fault detection. Frame and impeller materials typically follow the 8038 convention of die-cast aluminum or UL94V-0 PBT, balancing rigidity, flame resistance, and weight. With operating temperature ranges commonly reaching −10 °C to +70 °C, the series suits server and storage chassis, power inverters, telecom cabinets, industrial drives, welding equipment, and medical or instrumentation enclosures where a compact footprint must still overcome meaningful system impedance. Where the LBE9225 and LBMB9220 trade depth for fit, the LOBISONG LBA8038 trades depth for pressure and thermal headroom.

LOBISONG LBMB9220 Series
92mm x 92mm x 20mm
DC Axial Fan

LOBISONG LBMB9220 Series 92mm x 92mm x 20mm DC Axial Fan

The LOBISONG LBMB9220 Series is a line of 92 × 92 × 20 mm DC axial fans that prioritizes a reduced 20 mm profile without sacrificing the core performance expected from a standard 92 mm footprint. Where the 25 mm-thick LBE9225 series offers a wider airflow ceiling, the LBMB9220 is positioned for enclosures where depth is the tighter constraint, while still delivering a usable balance of cooling capacity and acoustic behavior.

Drawing on the widely published 9220-platform specifications that inform this class of fan, the series supports DC voltages spanning 5 V to 24 V, with 12 V and 24 V variants being the most common configurations. Speed options across comparable 9220 models generally range from 2,000 to 4,000 RPM. At the low-speed end, airflow can start around 39 CFM with noise levels near 28 dBA; at the higher-speed end, airflow can reach approximately 78 CFM with noise rising toward 40 dBA. Intermediate models fill the gap: for example, a representative 2,500 RPM variant delivers roughly 49 CFM at about 34 dBA, while a 3,000 RPM version pushes airflow toward the mid-60s CFM range. Static pressure spans from approximately 1.2 mmH₂O on low-speed versions to over 4 mmH₂O on high-speed versions, giving designers room to match the fan to either open-ventilation airflow or moderately restrictive filter and heatsink applications.

The fan frame and impeller are typically molded from UL94V-0-rated PBT thermoplastic, providing flame resistance and dimensional stability. Bearing construction can be specified as sleeve bearing or ball bearing, with ball-bearing versions suited to longer-duty cycles and higher operating temperatures. Standard lead connections use AWG 26 UL1007 wires, and the series supports a range of optional signal and control features: tachometer/FG output, rotation detection/alarm, PWM speed control, and thermal or voltage-based speed modulation are available depending on configuration. Motor protection commonly includes reverse-polarity protection and locked-rotor protection with auto-restart, helping safeguard the fan in fault conditions.

Operating temperature is generally rated for −10 °C to +70 °C under non-condensing conditions, with storage tolerance extending to −40 °C to +80 °C. This profile suits the LBMB9220 to space-constrained thermal designs in compact power supplies, small heaters, communications enclosures, instrumentation, and dense electronic chassis where a 25 mm fan would not physically fit but a 92 mm mounting pattern is already defined.

As with the LBE9225 series, the LBMB9220 is offered as a configurable platform rather than a single fixed SKU: voltage, speed grade, bearing system, and signal options are selected per application. The resulting fan remains a practical choice when low-profile integration, moderate-to-high airflow, and configurable control are the governing requirements.

LOBISIONG LBE9225 Series
92mm x 92mm x 25mm
DC Axial Fan

LOBISIONG LBE9225 Series 92mm x 92mm x 25mm DC Axial Fan

The LOBISIONG LBE9225 Series is a family of 92×92×25 mm DC axial fans engineered for reliable, long-life thermal management in compact electronic enclosures. Combining a standard 92 mm footprint with a slim 25 mm profile, this series delivers a practical balance of airflow, static pressure, and acoustic comfort for space-constrained designs.

Available in 5 V, 12 V, and 24 V DC variants, the LBE9225 supports flexible integration across different power architectures. Speed options typically span 2,100 to 4,200 RPM, producing air volumes in the range of 43.8 to 83.8 CFM, while noise levels are managed between approximately 29.8 and 44.9 dBA depending on the selected model. Users can choose from sleeve bearing or dual ball bearing constructions, with ball-bearing versions offering extended service life suitable for continuous-duty applications. The fan frame and impeller are commonly molded from PBT (UL94V-0) flame-retardant plastic, ensuring dimensional stability and safety compliance.

For advanced system integration, the series can be configured with tachometer output, alarm signal, PWM speed control, and polarity or rotor-lock protection, enabling real-time monitoring and fault detection in critical cooling loops. With an operating temperature range of −10 °C to +70 °C, the LBE9225 is suited to demanding environments including computer and server chassis, power supplies, communication equipment, medical devices, automotive electronics, and industrial control cabinets.

The series is manufactured under ISO9001 quality systems, and representative models carry CE, UL, TUV, and RoHS certifications, reflecting compliance with international safety and environmental standards. Whether the priority is low-noise operation for consumer electronics or high-airflow durability for industrial retrofits, the LOBISIONG LBE9225 Series offers a versatile, configuration-ready DC cooling platform.

LOBISONG LBG9225 Series
92mm x 92mm x 25mm
DC Axial Fan

LOBISONG LBG9225 Series 92mm x 92mm x 25mm DC Axial Fan

The LOBISONG LBG9225 Series is a line of 92 mm × 92 mm × 25 mm DC axial fans positioned for applications where the deeper 38 mm profile of the LBMS9238 is unnecessary, but reliable forced convection is still required. The 25 mm frame height makes it a standard drop-in fit for enclosures with tighter internal clearances.

Performance Range. The series accommodates 5 VDC, 12 VDC, 24 VDC, and 48 VDC inputs, with speed variants spanning roughly 2,000 RPM to 6,000 RPM. Low-speed configurations deliver approximately 43–45 CFM at noise levels around 27–30 dBA, while high-speed versions reach up to 107 CFM with static pressure near 0.77 inch H₂O—acoustics rising to the 52–53 dBA range.

Construction & Bearing Options. Frames and impellers are molded from UL94V-0 rated thermoplastic for flame resistance and dimensional stability. Bearing choices include sleeve, hydraulic, and dual ball bearing configurations, allowing a balance between cost sensitivity and long-life continuous operation.

Control & Protection. The platform supports PWM speed control, FG tachometer output, and RD rotation detection, with optional IP56 or IP68 ingress protection for dusty or washdown-prone environments.

Typical Applications. The LBG9225 is commonly specified for network enclosures, control panels, electronic cabinets, server racks, and general air-cooling systems where a slim 25 mm profile and flexible voltage options are decisive.

LOBISONG LBMS9238 Series
92mm x 92mm x 38mm
DC Axial Fan

LOBISONG LBMS9238 Series 92mm x 92mm x 38mm DC Axial Fan

The LOBISONG LBMS9238 Series is a family of 92 mm × 92 mm × 38 mm DC axial fans engineered for demanding thermal management where standard 25 mm-thick fans cannot deliver sufficient static pressure. The 38 mm depth provides a substantially larger impeller blade area, enabling airflow and pressure ratings that rival much larger frame sizes.

Key Performance Envelope. The series supports 12 VDC, 24 VDC, and 48 VDC input options, with speed variants typically ranging from 2,500 RPM to 9,000 RPM. At the high end, airflow reaches approximately 166 CFM (4.67 m³/min) with static pressure near 1.45 in H₂O (361 Pa)—figures comparable to premium industrial 9238 platforms. Lower-speed versions prioritize acoustic comfort, delivering around 80–125 CFM at noise levels in the 37–56 dBA range.

Construction & Reliability. Frames and impellers are typically molded from UL94V-0 rated PBT, balancing rigidity with flame resistance. Dual ball bearing systems are standard for long service life in continuous-duty applications, with some configurations offering IP55 or IP68 ingress protection for dust- and moisture-exposed environments.

Control & Integration. The platform accommodates PWM speed control, tachometer (FG) output, and rotation detection (RD) signals, allowing precise thermal modulation within server chassis, telecom cabinets, and industrial power supplies.

Typical Applications. LBMS9238-class fans are deployed in CCTV/NVR enclosures, automotive electronics, server racks, HVAC control panels, and medical or pharmaceutical thermal systems where a compact footprint and high static pressure are simultaneously required.

LBMR9238 Series
92mm x 92mm x 38mm
DC Axial Fan

LBMR9238 Series 92mm x 92mm x 38mm DC Axial Fan

The LBMR9238 Series is a 92mm x 92mm x 38mm DC axial fan built for reliable cooling in demanding electronic and industrial systems. Its 9238 frame provides a larger depth for higher static pressure and airflow, making it suitable for power supplies, inverters, control cabinets, telecom equipment, chargers, and compact machines with airflow resistance. The series supports flexible DC voltage, speed, bearing, connector, and lead-wire options to balance cooling performance, noise, and service life. A balanced impeller and sturdy housing help ensure stable operation, low vibration, easy installation, and long-term durability. LB offers OEM customization for voltage, speed, airflow, noise, and bearing type. Contact us with your application requirements to select the right LBMR9238 configuration.

LB LBMS1225 Series
120mm x 120mm x 25mm
DC Axial Fan

LB LBMS1225 Series 120mm x 120mm x 25mm DC Axial Fan

The LB LBMS1225 Series is a 120mm x 120mm x 25mm DC axial fan engineered for dependable cooling in electronic and industrial equipment. Its compact 12025 frame fits power supplies, control cabinets, telecom units, chargers, inverters, and other space-limited systems. The series offers flexible DC voltage, speed, bearing, connector, and lead-wire options to match airflow, noise, and service-life requirements. Balanced impeller design and a sturdy housing support stable performance, low vibration, and easy installation. Its 12025 form factor simplifies replacement and system integration, while consistent production and flexible options support OEM projects. LB provides customization for voltage, speed, airflow, noise, and bearing type. Contact us with your application details to select the right LBMS1225 configuration.

LOBISONG LBE1225 Series
120mm x 120mm x 25mm
DC Axial Fan

LOBISONG LBE1225 Series 120mm x 120mm x 25mm DC Axial Fan

The LOBISONG LBE1225 Series is a 120mm x 120mm x 25mm DC axial fan designed for reliable cooling and air movement in compact electronic and industrial systems. Its 12025 frame size suits power supplies, control cabinets, communication equipment, chargers, inverters, and space-conscious applications. The series supports flexible DC voltage, speed, bearing, connector, and lead-wire configurations to meet different airflow, noise, and service-life requirements. Balanced impeller geometry and a durable frame help deliver stable performance, easy installation, and long-term operation. LOBISONG offers customized options for OEM projects, including performance and electrical options. Contact us with your voltage, speed, airflow, noise, and bearing requirements to select the right LBE1225 version.

LOBISONG LBG1225 Series
120mm x 120mm x 25mm
DC Axial Fan

LOBISONG LBG1225 Series 120mm x 120mm x 25mm DC Axial Fan

LOBISONG LBG1225 Series — 120×120×25 mm DC Axial Fan

The LOBISONG LBG1225 is a 120 mm × 120 mm × 25 mm DC axial fan on the slim-profile 12025 platform, positioned as a general-purpose, cost-sensitive entry within LOBISONG’s 1225 lineup—comparable to how the LBG1238 occupies the baseline tier of the 38 mm family. Its 25 mm depth enables installation in compact chassis where 38 mm-class fans will not fit, while retaining the universal 120 mm mounting pattern.

Performance. The LBG1225 accommodates 5 V, 12 V, 24 V, and 48 V DC inputs. Across the 12025 envelope, configurations typically span roughly 1,500–2,700 RPM, with airflow of approximately 54–99 CFM and static pressure from 0.07 in H₂O (17 Pa) up to 0.22 in H₂O (55 Pa) at the upper end. Acoustic output ranges from about 26 dB(A) at low-speed settings to the low 40s dB(A) at maximum speed, making the series suitable for noise-conscious compact equipment.

Construction. The fan uses a brushless DC motor with a plastic impeller and ball bearing construction for stable long-term rotation. Housings and impellers are molded from fiberglass-reinforced PBT rated UL94V-0 for flame retardancy. Ball-bearing life is commonly specified around 65,000 hours at 45 °C, and protection features on comparable 12025 platforms include polarity protection and auto-restart, with PWM and tachometer (FG) options available on selected builds.

Applications. Suited to computers, power supplies, control units, communication products, small cabinets, and compact OEM cooling systems where 25 mm depth and dependable airflow are required.

Note: LBG1225 voltage, speed, bearing, and protection ratings vary by specific part number and should be confirmed against LOBISONG’s official datasheet before design integration.