The Lobisong LBAA2E185S-7MNW-01 is a Ø185 mm AC axial fan engineered for reliable fixed-speed ventilation and heat dissipation in demanding industrial environments.
Not every ventilation job has a three-phase power drop. For workshops, warehouses, and retrofit sites where only 220/230V mains is available, the Lobisong LBAA2E185S-7MNW-01 is a plug-and-play 185mm AC axial fan that needs no electrician, no phase converter, no new wiring run. Rated for 220/230V single-phase at 50Hz and spinning at 2400 RPM, this single-phase axial fan moves 670 m³/h—enough to ventilate a mid-size workshop, a warehouse aisle, or a commercial kitchen hood. At 51 dB(A) and IP54 protected, this IP54 ventilation fan combines high air delivery with everyday robustness.

Why single-phase? Because most small businesses, warehouses, and retrofit locations are wired for 220/230V wall power, not industrial three-phase. A workshop exhaust fan that demands 380V turns a simple replacement into a rewiring project. This 185mm axial fan avoids that: its winding accepts 220/230V across a 198–242V tolerance, so voltage sags from a starting compressor or dimmer will not stall it. A cold-rolled sheet impeller, balanced to G6.3 per JB/T8689, displaces 670 m³/h at a moderate 2400 RPM. The larger 185mm disc means it does not need to spin as fast as a smaller fan to move the same volume—which is why noise stays at 51 dB(A) rather than climbing into the uncomfortable range.
The mechanical build is tuned for hands-off operation. Class F insulation (155°C) and S1 continuous duty let this 185mm axial fan run around the clock, from a factory floor that never stops to a kitchen hood through every lunch service. IP54 keeps workshop dust and cooking grease spray out of the motor, while maintenance-free ball bearings with 30,000-hour L10 life mean this single-phase axial fan never enters the maintenance schedule. Operating across -30°C to +60°C, a winter warehouse or a summer workshop will not push this IP54 ventilation fan beyond rating.
Parameter |
Value |
Model |
LBAA2E185S-7MNW-01 |
Series |
LWAA2E185 |
Motor Type |
AC, 1-phase |
Voltage |
220/230V (range 198~242V) |
Frequency |
50Hz |
Current |
0.28 A |
Power |
55 W |
Speed |
2400 RPM |
Max Airflow |
670 m³/h |
Noise |
51 dB(A) |
Ambient Temperature |
-30°C ~ +60°C |
Storage Temperature |
-40°C ~ +80°C |
Humidity |
0~95% RH |
Altitude |
< 1000 m |
Impeller |
Ø185mm cold-rolled sheet |
Protection Rating |
IP54 |
Insulation Class |
Class F |
Bearing |
Maintenance-free ball bearings |
Duty |
S1 |
Balance Grade |
G6.3 |
Vibration Standard |
JB/T8689 |
Bearing Life |
30,000 h (L10) |
The physics behind this 185mm axial fan's easy operation come down to disc area. Airflow scales with swept area times tip speed. A 145mm impeller must spin much faster to move the same volume as a 185mm impeller—and faster tip speed drives noise. This workshop exhaust fan uses the larger 185mm disc to deliver 670 m³/h at a relaxed 2400 RPM, keeping 51 dB(A) within comfort for occupied spaces. For a retrofit contractor, mount this 185mm axial fan in a workshop where people work eight hours a day without triggering hearing-protection requirements.
Single-phase design also simplifies procurement. A maintenance manager replacing a failed exhaust fan does not need to know whether the building has three-phase—this 185mm axial fan works on whatever is on the wall. That removes the most common retrofit delay: "we measured the fan, but the circuit is 220V single-phase." The 55W draw runs from a standard branch circuit, and IP54 tolerates damp, dusty warehouses. For SMB buyers, plug-and-play wiring and 30,000-hour bearing life mean this 185mm axial fan is installed once and forgotten.
For contractors and SMB buyers, industrial fan ROI is simplicity. No need to inventory both single-phase and three-phase variants—this workshop exhaust fan runs on the power every workshop already has. The 55W draw boosts industrial fan ROI, and 30,000-hour L10 bearing life means the fan typically outlasts the equipment it serves. Because installation requires only a standard 220/230V connection, an electrician is not needed for most replacements. For distributors, stocking this single-phase axial fan model covers the bulk of retrofit and SMB ventilation enquiries—industrial fan ROI.

Q1: Can this 185mm axial fan be hard-wired to a 220V branch circuit?
A: Yes. It is rated for 220/230V single-phase with 198–242V tolerance. Hard-wiring to a standard branch circuit is typical; the 0.28A / 55W draw fits ordinary circuit protection. No three-phase supply is required beyond what is internal to the motor.
Q2: How much static pressure can this single-phase axial fan overcome?
A: 670 m³/h AC fan is low-to-medium pressure design for open grille, light ducted exhaust, and filter-backed cabinet applications. It moves 670 m³/h through a short low-loss duct run, but is not a substitute for a high-static-pressure centrifugal fan on heavily filtered systems. If duct resistance exceeds ~100 Pa, consider a centrifugal alternative.
Q3: Is this IP54 ventilation fan suitable for a commercial kitchen?
A: Yes—IP54 resists grease spray and kitchen dust, and single-phase supply matches typical restaurant power. It is not rated for pressure wash-down or direct water jets; schedule periodic impeller cleaning if heavy grease accumulates, and use a grease-rated filter upstream to protect airflow.

The Lobisong LBAA2E185S-7MNW-01 is a Ø185 mm AC axial fan engineered for reliable fixed-speed ventilation and heat dissipation in demanding industrial environments.