LBBE3G250-092NS-22 EC Purifier Centrifugal Fan

250mm EC backward curved centrifugal fan with aluminum alloy impeller, IP44 sealed, 1730m³/h at 145W for air purifiers and factory air purification systems.

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G250-092NS-22 is a 250mm EC backward curved centrifugal fan designed for air purification equipment and factory ventilation where a metal impeller and robust enclosure are preferred over plastic construction. Mounting an aluminum alloy / galvanized sheet impeller on a brushless EC motor, this backward curved centrifugal fan pushes 1730 m³/h at 2500 r/min on 145W shaft power, generating enough static pressure to hold airflow through filter media without high tip speeds. The housing is sealed to IP44, insulated to Class F/B, supplied for 230V 50/60Hz, and rated S1 continuous duty across -25℃ to +60℃. As the entry model of this four-variant 250/250 series, this backward curved centrifugal fan covers moderate-duty purifier cabinets and general plant air exchange, with three higher-power options extending output up to 370W.

Model Power Speed Air Flow
LBBE3G250-092NS-22 145W 2500 r/min 1730m³/h
LBBE3G250-102NS-24 240W 3150r/min 1524m³/h
LBBE3G250-102NS-25 270W 3170 r/min 1751m³/h
LBBE3G250-102NS-26 370W 3500 r/min 1700m³/h

Product Advantages

1. Metal Impeller for Filter-Load Pressure Build-Up

Where a plastic impeller can flex or age under sustained heat, this backward curved centrifugal fan uses an aluminum alloy and galvanized sheet rotor that keeps its blade pitch rigid at speed. The backward-inclined blade geometry converts shaft rotation into static pressure, the component that matters when air must cross a purifier pre-filter and HEPA layer rather than blow freely into open space. That pressure stability is why this backward curved centrifugal fan sustains 1730 m³/h as filter resistance climbs instead of dropping off like an axial blower. The metal rotor also shrugs off abrasive dust in factory airstreams and resists chemical cleaning agents used in maintained purification equipment, and its mass helps damp running vibration.

2. 145W EC Drive with Variable Speed

A brushless electronically commutated motor sits at the center of this backward curved centrifugal fan, replacing the shaded-pole or induction motors found on older replacement blowers. The EC drive keeps efficiency high across the speed range, so the unit can run slowed during low-load hours without wasting electricity, and its output can be trimmed steplessly rather than switched between fixed taps. In a purifier cabinet this lets the controller match fan rpm to measured particulate, cutting both sound and power when air is clean. Soft start-up also limits inrush current, which protects the purifier's own power board and contactor on repeated daily cycling.

Product Overview

Product Overview

Product Overview

Product Overview

3. IP44 Sealing for Protected Purifier and Cabinet Installations

The whole assembly is rated IP44, meaning the enclosure keeps solid foreign objects over 1mm out and resists splashing water from any direction. That level of sealing fits the typical home and light-industrial purifier cabinet, where the blower sits behind an intake panel rather than exposed to washdown hoses or heavy dust streams. Sealed around the windings and bearing, this backward curved centrifugal fan avoids the winding corrosion and bearing grit that shorten open-frame blower life in dusty rooms, while the IP44 housing avoids the extra cost of full IP55 sealing where the environment does not demand it.

4. Class F/B Insulation Across a Wide Temperature Window

Insulation on the motor winding is Class F/B, giving thermal headroom for sustained full-load running inside a closed purifier cabinet where airflow over the motor itself is limited. The specified ambient window of -25℃ to +60℃ covers cool plant rooms, heated commercial spaces and seasonal temperature swings without asking the unit to derate, and the S1 duty rating confirms this backward curved centrifugal fan is built for non-stop continuous duty rather than intermittent short bursts. The 230V 50/60Hz supply matches standard commercial grids, keeping the same model compatible across export markets without a separate motor variant.

5. Four Power Tiers Sharing the Same 2 kg Assembly

The four SKUs in this family all keep a 2 kg frame and 250mm impeller envelope, so a cabinet duct collar can be standardized while the internal power level varies by application. The 092NS-22 backward curved centrifugal fan at 145W and 1730 m³/h handles purifier cabinets and plant air exchange; the 102NS-24 at 240W and 1524 m³/h serves hotel ventilation; the 102NS-25 at 270W and 1751 m³/h feeds air conditioning cabinets; the 102NS-26 at 370W and 1700 m³/h covers heavy factory exhaust. Sealed ball bearings need no periodic lubrication, and every unit leaves with CE, RoHS, ETL, BSCI, CCC and ISO certification.

Product Overview

Product Overview

Product Overview

Product Overview

Application Scenarios

  • Commercial and Industrial Air Purifiers: This backward curved centrifugal fan forms the pressure-generating core of standalone purifiers, wall-mounted purifier modules and dust-collection cabinets, moving air through multi-stage filters while keeping cabinet noise acceptable in occupied rooms.
  • Factory Plant Air Exchange: Installed in workshop ventilation ducts and air handling compartments, this backward curved centrifugal fan discharges accumulated process heat and airborne dust, supporting comfortable conditions on production floors.
  • HVAC and AC Cabinet Supply Air: The higher-power variants in the family push conditioned air through coil banks and distribution ducts, with the metal impeller suited to continuous HVAC service in commercial buildings.
  • Enclosure and Equipment Cooling: Inside electrical enclosures and packaged industrial equipment, this backward curved centrifugal fan provides directed high-pressure airflow to heat sinks and control components, with IP44 protection for cabinet-mounted service.

Frequently Asked Questions

Q: Why does this purifier fan use a metal impeller? A: The aluminum alloy / galvanized sheet rotor in this backward curved centrifugal fan stays rigid under heat and abrasive dust, resists cleaning chemicals, and damps vibration at speed. It is chosen for purification equipment where filter resistance and long service life matter more than the lowest possible unit weight.

Q: Which variant should match a given airflow target? A: The 092NS-22 gives 1730 m³/h at 145W for purifiers and general plant ventilation; the 102NS-24 gives 1524 m³/h at 240W; the 102NS-25 gives 1751 m³/h at 270W for AC cabinets; the 102NS-26 gives 1700 m³/h at 370W for heavy factory exhaust. All share the same 2 kg frame.

Q: Is the fan speed adjustable, and can it run all day? A: The EC motor supports stepless speed regulation, and the unit is S1 continuous duty with sealed ball bearings, so this backward curved centrifugal fan is rated for non-stop running within the -25℃ to +60℃ ambient range.

LBBE3G250-092NS-22 EC Purifier Centrifugal Fan

250mm EC backward curved centrifugal fan with aluminum alloy impeller, IP44 sealed, 1730m³/h at 145W for air purifiers and factory air purification systems.