LBBE3G280-072PS-01 EC Turbine Centrifugal Fan

LBBE3G280-072PS-01 low-noise EC backward curved centrifugal turbine fan, 2318m³/h at 170W, large airflow for fresh air systems and exhaust ventilation.

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G280-072PS-01 is a 280mm EC backward curved centrifugal fan built for purified fresh air systems, large-airflow ventilation and general exhaust duty. Driven by an EC brushless motor, this backward curved centrifugal fan delivers 2318 m³/h at 1910 r/min on 170W shaft power, moving a large volume of air at a relatively low rotational speed, which supports the quiet operation expected of fresh air and indoor air quality equipment. Rated for continuous duty at 3 kg frame weight, this backward curved centrifugal fan is the entry model of a five-variant 280mm family that scales output from 170W up to 1355W and airflow to 3863 m³/h, so one impeller size covers everything from kitchen exhaust to mining and high-power HVAC ventilation.

Model Power Speed Air Flow
LBBE3G280-072PS-01 170W 1910 r/min 2318m³/h
LBBE3G280-092PS-03 225W 2650 r/min 2009 m³/h
LBBE3G280-102PS-04 700W 3270 r/min 3863 m³/h
LBBE3G280-138PT-05 860W 3000 r/min 3028 m³/h
LBBE3G280-138PT-06 1355W 3500 r/min 3790 m³/h

Product Advantages

1. Large 280mm Impeller for High-Airflow Fresh Air Duty

This backward curved centrifugal fan uses a 280mm impeller sized to move large volumes of air rather than chase extreme pressure, which is the right geometry for fresh air systems and general ventilation where rooms need steady make-up air. The backward-inclined blade path turns motor rotation into stable airflow with less turbulence than a radial blade design, helping this backward curved centrifugal fan keep outlet noise low even at 2318 m³/h. The large impeller also lets the unit reach rated airflow at a modest 1910 r/min, reducing blade tip speed and the broadband noise that high-speed small rotors produce in occupied spaces.

2. 170W EC Drive with Low-Speed Quiet Running

The EC brushless motor of this backward curved centrifugal fan runs efficiently across its speed range, so the unit can be trimmed down during light-use periods instead of throttled with a damper that wastes energy as pressure loss. Stepless speed regulation lets a fresh air controller ramp the backward curved centrifugal fan up as occupancy rises and settle it back after peak hours, balancing indoor air quality against noise and running cost. Soft-start current limiting protects upstream circuits from startup surge, and the EC drive keeps heat generation in the motor lower than an equivalent conventional motor.

Product Overview

Product Overview

Product Overview

Product Overview

Product Overview

Product Overview

Product Overview

Product Overview

3. Five Output Steps on One 280mm Platform

All five models in this family keep a 3 kg frame and 280mm impeller envelope, so a common duct collar and mounting interface can serve every power level. The 072PS-01 backward curved centrifugal fan at 170W and 2318 m³/h covers kitchen exhaust and fresh air ventilation; the 092PS-03 at 225W and 2009 m³/h serves factory exhaust; the 102PS-04 at 700W and 3863 m³/h handles mining and heavy industrial exhaust; the 138PT-05 at 860W and 3028 m³/h covers hotel exhaust; the 138PT-06 at 1355W and 3790 m³/h serves high-power AC exhaust. That shared platform lets a single backward curved centrifugal fan reference span several product lines, from light ventilation to high-pressure plant duty.

4. Broad Application Range Across Ventilation Markets

Because the family stretches from 170W to 1355W, this backward curved centrifugal fan platform can be matched to very different airflow jobs without redesigning the enclosure. The low-speed 072PS-01 suits indoor fresh air units and hood systems where noise is heard; the mid models cover workshops and hotel ducts; the high-power PT variants handle mining ventilation, industrial exhaust and AC cabinets where pressure and volume are both high. System integrators can specify one backward curved centrifugal fan family and select the right output tier for each project's duct resistance and room volume.

5. Continuous-Duty Build and Service Considerations

This unit is built as an exhaust and ventilation blower for sustained daily operation, and its 3 kg frame is sized to mount directly in ductwork, fan boxes or packaged ventilation units. Bearing lubrication and sealing details should be confirmed from the product spec sheet before listing, as should insulation class, protection rating, operating temperature and supply voltage. Once those fields are verified, this backward curved centrifugal fan can be positioned as a standard OEM blower for fresh air systems, kitchen hoods and industrial exhaust, with spare variants held in the same family for future projects.

Product Overview

Product Overview

Application Scenarios

  • Purified Fresh Air Systems: This backward curved centrifugal fan supplies make-up air to fresh air units and air handling systems, pushing conditioned outdoor air through filters and distribution ducts in commercial buildings and offices.
  • Kitchen Exhaust Ventilation: Mounted in range hoods and ducted exhaust boxes, this backward curved centrifugal fan discharges cooking fume and heat from commercial kitchens at a steady 2318 m³/h.
  • Factory and Workshop Air Exchange: In production halls, the fan supports general air exchange and heat removal, working alongside other family models sized for heavier plant exhaust.
  • Industrial and Large-Scale Ventilation: The high-power PT variants in the family extend the platform to mining ventilation, hotel exhaust and AC cabinet airflow, where large volume and sustained duty are required.

Frequently Asked Questions

Q: What airflow does the 072PS-01 deliver? A: This backward curved centrifugal fan delivers 2318 m³/h at 1910 r/min with 170W shaft power, suited to standard fresh air systems, kitchen exhaust and general workshop ventilation.

Q: Which family variant should I compare against? A: The 092PS-03 gives 2009 m³/h at 225W for factory exhaust; the 102PS-04 gives 3863 m³/h at 700W for mining duty; the 138PT-05 gives 3028 m³/h at 860W for hotels; the 138PT-06 gives 3790 m³/h at 1355W for AC exhaust. All share the 280mm impeller and 3 kg frame.

Q: What technical fields still need confirmation? A: Impeller material, bearing type, protection class, insulation class, operating temperature, supply voltage and certifications are not shown in the supplied parameter image. Please check the product spec sheet before finalizing the listing copy and backend attributes.

LBBE3G280-072PS-01 EC Turbine Centrifugal Fan

LBBE3G280-072PS-01 low-noise EC backward curved centrifugal turbine fan, 2318m³/h at 170W, large airflow for fresh air systems and exhaust ventilation.

Request a Quote

Featured Products

lbbe3g280 072ps 01 ec turbine centrifugal fan-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000