LBBE3G280-092PS-15 EC backward curved centrifugal fan, galvanized/aluminum impeller, IP44 seal, 1813m³/h at 165W for factory heat dissipation.
The LBBE3G280-092PS-15 is a 280mm EC backward curved centrifugal fan designed for factory workshop heat dissipation and general ventilation. Built with a galvanized sheet / aluminum alloy impeller on an EC brushless motor, this backward curved centrifugal fan delivers 1813 m³/h at 2600 r/min on 165W shaft power, moving steady airflow against moderate duct and equipment resistance. The assembly carries IP44 sealing, Class F insulation, S1 continuous duty and a -25℃ to +60℃ ambient rang e, supplied for 230V/115V 50/60Hz. As the entry model of this four-variant 280mm PS family, this backward curved centrifugal fan covers standard factory heat dissipation, while the other three variants scale from 340W to 625W for fire smoke exhaust systems, heavy factory ventilation and kitchen fume extraction.
| Model | Power | Speed | Air Flow |
| LBBE3G280-092PS-15 | 165W | 2600 r/min | 1813m³/h |
| LBBE3G280-102PS-16 | 340W | 2760 r/min | 2318 m³/h |
| LBBE3G280-102PS-18 | 475W | 3100 r/min | 2472 m³/h |
| LBBE3G280-102PS-19 | 625W | 3000 r/min | 3039 m³/h |
The core of this backward curved centrifugal fan is a 280mm impeller formed in galvanized sheet or aluminum alloy, with a backward-inclined blade path tuned for duct and equipment resistance. Galvanized sheet resists rust in humid or dusty plant air, while aluminum alloy adds rotor lightness and corrosion resistance where the airstream carries fine particulate. The backward curved geometry converts motor rotation into static pressure rather than free velocity, so this backward curved centrifugal fan keeps 1813 m³/h moving through duct elbows and intake screens instead of losing throughput once resistance rises. The balanced metal rotor keeps vibration and outlet turbulence controlled at 2600 r/min, suiting installation near occupied production areas.
This backward curved centrifugal fan runs on an EC brushless motor rated at 165W, which keeps efficiency high across the speed range rather than only at one fixed point. The electronically commutated drive lets the unit be slowed during light-load shifts instead of throttled with a damper that wastes energy as pressure loss, and output can be trimmed steplessly to match actual machine heat. In a workshop where heat load varies by shift, turning the backward curved centrifugal fan down saves power proportionally, because fan energy falls roughly with the cube of speed. Soft-start current limiting also protects upstream circuits and contactors from startup surge.




Rated IP44, this factory centrifugal blower keeps solid foreign objects over 1mm out and resists splashing water from any direction, a sensible level of protection for indoor ventilation cabinets, ducted exhaust boxes and equipment compartments in production plants. The sealed motor housing keeps dust and incidental moisture away from windings and ball bearings, so this backward curved centrifugal fan holds performance steady where an open-frame blower would collect grit and drift in output over time. The IP44 enclosure avoids the added cost of full high-grade sealing in zones that do not demand it, keeping the unit cost-effective for standard factory ventilation.
Class F winding insulation gives this backward curved centrifugal fan thermal headroom under sustained full-load operation, which matters when the motor sits inside a ventilation plenum or equipment enclosure that traps its own heat. The rated -25℃ to +60℃ ambient range covers cold unheated workshops, warm summer production floors and seasonal plant-room swings without derating. S1 duty confirms this backward curved centrifugal fan is built for non-stop continuous operation rather than intermittent short bursts, and the 230V/115V 50/60Hz supply matches two common commercial grids for export factory ventilation projects.
All four models in this family keep a 3 kg frame and 280mm impeller envelope, so one duct collar and mounting interface can serve every power level. The 092PS-15 backward curved centrifugal fan at 165W and 1813 m³/h covers standard workshop heat dissipation; the 102PS-16 at 340W and 2318 m³/h serves fire smoke exhaust systems; the 102PS-18 at 475W and 2472 m³/h handles heavier factory exhaust; the 102PS-19 at 625W and 3039 m³/h covers kitchen fume extraction. Sealed ball bearings run without a relubrication schedule, and every unit carries CE, RoHS, ETL, BSCI, CCC and ISO certification, giving a single backward curved centrifugal fan platform across light ventilation, exhaust and smoke extraction duty.




Q: What airflow does the 092PS-15 deliver? A: This backward curved centrifugal fan delivers 1813 m³/h at 2600 r/min with 165W shaft power, suited to standard factory workshop heat dissipation and general ventilation.
Q: Is this unit suitable for continuous operation? A: Yes. This backward curved centrifugal fan is rated S1 continuous duty with sealed ball bearings and Class F insulation, built for non-stop running within the -25℃ to +60℃ ambient range.
Q: Which family variant should I compare for heavier exhaust? A: The 102PS-16 gives 2318 m³/h at 340W for fire smoke exhaust; the 102PS-18 gives 2472 m³/h at 475W for factory exhaust; the 102PS-19 gives 3039 m³/h at 625W for kitchen extraction. All share the 280mm impeller and 3 kg frame.