products_4, products_4, /products
Inquiry
Inquiry

Products

LBBE3G190-072PS-06 EC Low Noise Blower Fan

LBBE3G190-072PS-06 EC Low Noise Blower Fan

190mm low-noise EC backward curved centrifugal fan with PA66 impeller, IP54/IP55, 639m³/h for air purifiers and smart home appliances.

LOBISONG LBMS8025 Series
80mm x 80mm x 25mm
DC Axial Fan

LOBISONG LBMS8025 Series 80mm x 80mm x 25mm DC Axial Fan

LOBISONG LBMS8025 Series: 80×80×25 mm DC axial fan available in 5 V, 12 V, 24 V, and 48 V options, with speed grades commonly spanning roughly 2,000 to 7,200 RPM depending on the selected variant. Typical performance in the 8025 footprint ranges from about 31 CFM to 72 CFM, with noise levels between approximately 28 dBA and 57 dBA across the speed spectrum. The slim 25 mm profile makes the LBMS8025 a natural fit for space-constrained enclosures where depth is limited but forced convection is still required—including computer chassis, power supplies, AV equipment, 3D printers, and compact industrial controllers. Bearing options across this series typically include sleeve, dual ball, and hydraulic bearings, with housing and impeller molded from UL94V-0 flame-retardant plastic. Supported features commonly include PWM speed control, FG tachometer output, and optional locked-rotor or rotational-detection signals, with 2-pin, 3-pin, and 4-pin connector configurations available. Lower-speed variants prioritize quiet operation for consumer and office environments, while higher-speed models deliver maximum airflow within the 80×25 mm envelope for denser thermal loads. Verify the exact LBMS8025 sub-model code for voltage, bearing type, speed grade, and control configuration against LOBISONG's official datasheet before finalizing, as specifications vary by variant.

LOBISONG LBG8032 Series
80mm x 80mm x 32mm
DC Axial Fan

LOBISONG LBG8032 Series 80mm x 80mm x 32mm DC Axial Fan

LOBISONG LBG8032 Series: 80×80×32 mm DC axial fan offered in 12 V, 24 V, and 48 V options, with speed grades spanning roughly 3,500 RPM to 6,500 RPM to match different airflow and acoustic targets. Typical performance in this footprint ranges from about 43 CFM to 80 CFM, with noise levels between approximately 47.7 dBA and 58 dBA depending on the selected speed variant. The 32 mm depth provides a useful middle ground between slim 25 mm fans and high-pressure 38 mm designs, making the LBG8032 suitable for industrial control cabinets, laboratory equipment, telecom enclosures, and electronics cooling where moderate static pressure is required without excessive bulk. Construction typically uses PBT UL94V-0 plastic or aluminum alloy for flame resistance and durability, with dual ball bearing or sleeve bearing options available across the series. Supported features commonly include PWM speed control, FG tachometer output, polarity protection, and locked-rotor protection, with CE, FCC, RoHS, and ISO:9001 certifications typical for this class. Operating temperature is rated around −10 °C to 70 °C. Select a lower-speed variant for quieter operation or a higher-speed model for maximum cooling within the 80×32 mm envelope. Verify the exact LBG8032 sub-model code for voltage, bearing type, and control configuration with the manufacturer's datasheet before finalizing, as specifications vary by variant.

LOBISONG LBMR8032 Series
80mm x 80mm x 32mm
DC Axial Fan

LOBISONG LBMR8032 Series 80mm x 80mm x 32mm DC Axial Fan

LOBISONG LBMR8032 Series: 80×80×32 mm DC axial fan available in 12 V or 24 V, offered in four speed grades—L, M, H, and E—to match airflow and noise requirements. The series spans roughly 61 CFM at 41.6 dBA (5,000 RPM) up to 79 CFM at 50.4 dBA (6,500 RPM), with maximum static pressure rising from 1.72 to 2.23 in H₂O across the range. The 32 mm depth provides a middle ground between slim 25 mm fans and high-pressure 38 mm designs, making it suitable for electronics, telecom gear, and industrial enclosures where moderate pressure capability is needed without the bulk of a deeper fan. Construction uses UL94V-0 plastic impeller and frame, with ball bearing or sleeve bearing options depending on the variant. Available features include tachometer output, locked-rotor alarm, PWM speed control, soft start, polarity protection, and auto-restart. The series carries CE, cUL, TUV, and UL approvals, and weighs approximately 145 g. Select the L model for quiet operation, M for balanced performance, H for higher airflow, or E for maximum cooling in this footprint. Verify the exact LBMR8032 sub-model code for your voltage, bearing, and control configuration before finalizing.

LOBISONG LBMC8038 Series
80mm x 80mm x 38mm
DC Axial Fan

LOBISONG LBMC8038 Series 80mm x 80mm x 38mm DC Axial Fan

LOBISONG LBMC8038 Series: 80×80×38mm DC axial fan. 12V/24V, dual ball bearing, ~5500 RPM, 72 CFM, 51 dBA, 50,000 hrs, PWM optional.

This compact 80mm fan delivers a strong balance of high airflow and static pressure within a 38mm deep frame, making it suitable for dense electronics, telecom equipment, and industrial enclosures where space is constrained. The dual ball bearing construction supports a rated life of approximately 50,000 hours, while the ~5500 RPM speed class puts it in the high-performance tier for this footprint. With a noise level around 51 dBA and airflow near 72 CFM, it targets applications that need forceful cooling without crossing into the loudest end of the 80×38mm spectrum. PWM and tachometer options are commonly available in this format for speed control and monitoring.

LBBE3G190-072PS-01 EC AC Centrifugal Blower

LBBE3G190-072PS-01 EC AC Centrifugal Blower

190mm EC backward curved centrifugal fan with PA66 impeller, IP55 rated, delivers 814m³/h for air conditioning and kitchen exhaust systems.

LBBE3G190-072NS-14 EC Centrifugal Blower Fan

LBBE3G190-072NS-14 EC Centrifugal Blower Fan

190mm energy-saving EC backward curved centrifugal fan with PA66 impeller, IP55/IP54, 639m³/h for equipment room and workshop ventilation.

LBBE3G190-072NS-06 EC Backward Curved Fan

LBBE3G190-072NS-06 EC Backward Curved Fan

190mm high-output EC backward curved centrifugal fan with PA66 impeller, IP55 rated, delivers 973m³/h for factory heat dissipation and commercial ventilation.

LBBE3G175-072PS-04 EC Heat Dissipation Fan

LBBE3G175-072PS-04 EC Heat Dissipation Fan

175mm high-speed EC backward curved centrifugal fan with PA66 impeller, IP54/IP55, delivers 912m³/h for kitchen exhaust and industrial heat dissipation.

LBBE3G175-072PS-01 EC Exhaust Centrifugal Fan

LBBE3G175-072PS-01 EC Exhaust Centrifugal Fan

LBBE3G175-072PS-01 compact EC backward curved centrifugal fan with PA66 impeller, IP55 grease-resistant seal, built for kitchen exhaust and EFU ventilation.

LBBE3G190-072NS-14 EC Backward Curved Fan

LBBE3G190-072NS-14 EC Backward Curved Fan

LBBE3G190-072NS-14 low-power EC backward curved centrifugal fan with PA66 impeller, IP55/IP54 optional, built for energy-saving workshop and factory ventilation.

LOBISONG LBMS8038 Series
80mm x 80mm x 38mm
DC Axial Fan

LOBISONG LBMS8038 Series 80mm x 80mm x 38mm DC Axial Fan

The LOBISONG LBMS8038 Series is an 80 × 80 × 38 mm DC axial fan platform that inherits the core engineering premise of the 8038 form factor: 38 mm of depth is spent on pressure, not cosmetics. Where a 25 mm fan trades thickness for fit, the LBMS8038 uses the extra volume for a deeper blade section and a stronger motor, positioning it for thermal paths where backpressure rises faster than open-vent airflow falls.

Across the 8038 platform, configurations span 12 V, 24 V, and 48 V DC, with speed grades from roughly 3,500 RPM to beyond 9,000 RPM in documented variants; representative platform data show airflow ranging from approximately 98 m³/h at the low-speed end to over 180 m³/h at higher grades, with static pressure capability reaching 130–300 Pa in mainstream configurations and climbing substantially in high-output versions. Dual ball bearing construction is the standard specification for continuous-duty operation, while PWM speed control, FG tachometer output, and locked-rotor auto-restart can be specified for closed-loop thermal management. Note that the “MS8038” designation appearing in distribution channels belongs to Mechatronics, not LOBISONG; LBMS8038-specific ratings should be confirmed against LOBISONG’s own selection table for the exact SKU.

With operating temperature commonly rated to −10 °C to +70 °C, the LBMS8038 suits inverters, energy-storage enclosures, telecom chassis, industrial drives, and instrumentation where an 80 mm mounting pattern must still generate meaningful pressure against filters, fins, or ducted paths. Where the LBE9225 and LBMB9220 optimize for fit, the LBMS8038 is selected when the cooling problem is pressure head under constraint.

LOBISONG LBMR8038 Series
80mm x 80mm x 38mm
DC Axial Fan

LOBISONG LBMR8038 Series 80mm x 80mm x 38mm DC Axial Fan

The LOBISONG LBMR8038 Series is an 80 × 80 × 38 mm DC axial fan platform where the defining dimension is depth: the 38 mm thickness accommodates a wider blade section and a stronger motor than 25 mm or 20 mm fans of the same 80 mm footprint, making this series a static-pressure-first solution rather than a slim-fit compromise。In the 8038 class, the governing thermal problem is rarely open-vent airflow; it is moving air through dense heatsink fins, filter media, ducted paths, and crowded chassis interiors where backpressure rises quickly。

Across the 8038 platform, configurations commonly span 12 V, 24 V, and 48 V DC, with mainstream speed grades from roughly 3,400 RPM to 6,000 RPM and high-output variants reaching 8,000–15,000 RPM depending on the selected SKU。In the mainstream band, airflow typically lands between 45 CFM and 77 CFM, with noise tracking from approximately 39 dBA to 50 dBA。The series' advantage is static pressure: representative 8038 models deliver capabilities spanning roughly 7 mmH₂O at the low-speed end to 18–25 mmH₂O at higher speed grades, with high-speed industrial versions pushing considerably further。Dual ball bearing construction is the usual specification for continuous-duty operation, commonly rated for 50,000 hours, while sleeve bearing remains available for cost-sensitive or lower-duty designs。

The LBMR8038 is offered as a configurable platform, not a fixed SKU. PWM speed control, FG tachometer output, locked-rotor alarm, and auto-restart protection can be specified to support closed-loop thermal management and fault detection。Frame and impeller materials follow the 8038 convention of UL94V-0-rated PBT or die-cast aluminum, and some industrial variants extend protection to IP54 through IP68 for dust- and moisture-exposed installations。With operating temperature ranges commonly reaching −10 °C to +70 °C, the LBMR8038 suits power inverters, telecom and server chassis, industrial drives, welding equipment, and medical or instrumentation enclosures where an 80 mm mounting pattern must still overcome meaningful system impedance。Where the LBE9225 and LBMB9220 trade depth for fit, the LOBISONG LBMR8038 trades depth for pressure and thermal headroom under backpressure。

LOBISONG LBA8038 Series
80mm x 80mm x 38mm
DC Axial Fan

LOBISONG LBA8038 Series 80mm x 80mm x 38mm DC Axial Fan

The LOBISONG LBA8038 Series is an 80 × 80 × 38 mm DC axial fan platform defined by its 38 mm depth—a thickness that separates it from standard 25 mm and 20 mm fans by prioritizing static pressure and airflow density over slim-profile integration. In the 8038 class, the extra depth accommodates a wider blade section and a more powerful motor, making this series the appropriate choice when the cooling challenge is not open-vent airflow but pushing air through restrictive paths: dense heatsink fins, filter media, ducted channels, and crowded chassis interiors.

Across the 8038 platform, configurations commonly span 12 V, 24 V, and 48 V DC, with speed grades stretching from roughly 2,500 RPM to 5,500 RPM in mainstream variants and reaching substantially higher in high-speed industrial versions. In the mainstream range, airflow typically lands between 38 CFM and 73 CFM, with noise tracking from about 32 dBA to 51 dBA depending on the selected speed grade. Static pressure is the defining advantage: representative 8038 models deliver pressure capabilities in the 7–15 mmH₂O range at moderate speeds, and considerably higher in high-output configurations. Dual ball bearing construction is the standard choice for long-duty operation, commonly rated for 50,000 hours, while sleeve bearing options remain available for cost-sensitive, lower-duty designs.

The LBA8038 is offered as a configurable platform rather than a fixed SKU. PWM speed control, FG tachometer output, rotation alarm, and auto-restart locked-rotor protection can be specified to support closed-loop thermal management and fault detection. Frame and impeller materials typically follow the 8038 convention of die-cast aluminum or UL94V-0 PBT, balancing rigidity, flame resistance, and weight. With operating temperature ranges commonly reaching −10 °C to +70 °C, the series suits server and storage chassis, power inverters, telecom cabinets, industrial drives, welding equipment, and medical or instrumentation enclosures where a compact footprint must still overcome meaningful system impedance. Where the LBE9225 and LBMB9220 trade depth for fit, the LOBISONG LBA8038 trades depth for pressure and thermal headroom.

LOBISONG LBMB9220 Series
92mm x 92mm x 20mm
DC Axial Fan

LOBISONG LBMB9220 Series 92mm x 92mm x 20mm DC Axial Fan

The LOBISONG LBMB9220 Series is a line of 92 × 92 × 20 mm DC axial fans that prioritizes a reduced 20 mm profile without sacrificing the core performance expected from a standard 92 mm footprint. Where the 25 mm-thick LBE9225 series offers a wider airflow ceiling, the LBMB9220 is positioned for enclosures where depth is the tighter constraint, while still delivering a usable balance of cooling capacity and acoustic behavior.

Drawing on the widely published 9220-platform specifications that inform this class of fan, the series supports DC voltages spanning 5 V to 24 V, with 12 V and 24 V variants being the most common configurations. Speed options across comparable 9220 models generally range from 2,000 to 4,000 RPM. At the low-speed end, airflow can start around 39 CFM with noise levels near 28 dBA; at the higher-speed end, airflow can reach approximately 78 CFM with noise rising toward 40 dBA. Intermediate models fill the gap: for example, a representative 2,500 RPM variant delivers roughly 49 CFM at about 34 dBA, while a 3,000 RPM version pushes airflow toward the mid-60s CFM range. Static pressure spans from approximately 1.2 mmH₂O on low-speed versions to over 4 mmH₂O on high-speed versions, giving designers room to match the fan to either open-ventilation airflow or moderately restrictive filter and heatsink applications.

The fan frame and impeller are typically molded from UL94V-0-rated PBT thermoplastic, providing flame resistance and dimensional stability. Bearing construction can be specified as sleeve bearing or ball bearing, with ball-bearing versions suited to longer-duty cycles and higher operating temperatures. Standard lead connections use AWG 26 UL1007 wires, and the series supports a range of optional signal and control features: tachometer/FG output, rotation detection/alarm, PWM speed control, and thermal or voltage-based speed modulation are available depending on configuration. Motor protection commonly includes reverse-polarity protection and locked-rotor protection with auto-restart, helping safeguard the fan in fault conditions.

Operating temperature is generally rated for −10 °C to +70 °C under non-condensing conditions, with storage tolerance extending to −40 °C to +80 °C. This profile suits the LBMB9220 to space-constrained thermal designs in compact power supplies, small heaters, communications enclosures, instrumentation, and dense electronic chassis where a 25 mm fan would not physically fit but a 92 mm mounting pattern is already defined.

As with the LBE9225 series, the LBMB9220 is offered as a configurable platform rather than a single fixed SKU: voltage, speed grade, bearing system, and signal options are selected per application. The resulting fan remains a practical choice when low-profile integration, moderate-to-high airflow, and configurable control are the governing requirements.

LOBISIONG LBE9225 Series
92mm x 92mm x 25mm
DC Axial Fan

LOBISIONG LBE9225 Series 92mm x 92mm x 25mm DC Axial Fan

The LOBISIONG LBE9225 Series is a family of 92×92×25 mm DC axial fans engineered for reliable, long-life thermal management in compact electronic enclosures. Combining a standard 92 mm footprint with a slim 25 mm profile, this series delivers a practical balance of airflow, static pressure, and acoustic comfort for space-constrained designs.

Available in 5 V, 12 V, and 24 V DC variants, the LBE9225 supports flexible integration across different power architectures. Speed options typically span 2,100 to 4,200 RPM, producing air volumes in the range of 43.8 to 83.8 CFM, while noise levels are managed between approximately 29.8 and 44.9 dBA depending on the selected model. Users can choose from sleeve bearing or dual ball bearing constructions, with ball-bearing versions offering extended service life suitable for continuous-duty applications. The fan frame and impeller are commonly molded from PBT (UL94V-0) flame-retardant plastic, ensuring dimensional stability and safety compliance.

For advanced system integration, the series can be configured with tachometer output, alarm signal, PWM speed control, and polarity or rotor-lock protection, enabling real-time monitoring and fault detection in critical cooling loops. With an operating temperature range of −10 °C to +70 °C, the LBE9225 is suited to demanding environments including computer and server chassis, power supplies, communication equipment, medical devices, automotive electronics, and industrial control cabinets.

The series is manufactured under ISO9001 quality systems, and representative models carry CE, UL, TUV, and RoHS certifications, reflecting compliance with international safety and environmental standards. Whether the priority is low-noise operation for consumer electronics or high-airflow durability for industrial retrofits, the LOBISIONG LBE9225 Series offers a versatile, configuration-ready DC cooling platform.

LOBISONG LBG9225 Series
92mm x 92mm x 25mm
DC Axial Fan

LOBISONG LBG9225 Series 92mm x 92mm x 25mm DC Axial Fan

The LOBISONG LBG9225 Series is a line of 92 mm × 92 mm × 25 mm DC axial fans positioned for applications where the deeper 38 mm profile of the LBMS9238 is unnecessary, but reliable forced convection is still required. The 25 mm frame height makes it a standard drop-in fit for enclosures with tighter internal clearances.

Performance Range. The series accommodates 5 VDC, 12 VDC, 24 VDC, and 48 VDC inputs, with speed variants spanning roughly 2,000 RPM to 6,000 RPM. Low-speed configurations deliver approximately 43–45 CFM at noise levels around 27–30 dBA, while high-speed versions reach up to 107 CFM with static pressure near 0.77 inch H₂O—acoustics rising to the 52–53 dBA range.

Construction & Bearing Options. Frames and impellers are molded from UL94V-0 rated thermoplastic for flame resistance and dimensional stability. Bearing choices include sleeve, hydraulic, and dual ball bearing configurations, allowing a balance between cost sensitivity and long-life continuous operation.

Control & Protection. The platform supports PWM speed control, FG tachometer output, and RD rotation detection, with optional IP56 or IP68 ingress protection for dusty or washdown-prone environments.

Typical Applications. The LBG9225 is commonly specified for network enclosures, control panels, electronic cabinets, server racks, and general air-cooling systems where a slim 25 mm profile and flexible voltage options are decisive.

LOBISONG LBMS9238 Series
92mm x 92mm x 38mm
DC Axial Fan

LOBISONG LBMS9238 Series 92mm x 92mm x 38mm DC Axial Fan

The LOBISONG LBMS9238 Series is a family of 92 mm × 92 mm × 38 mm DC axial fans engineered for demanding thermal management where standard 25 mm-thick fans cannot deliver sufficient static pressure. The 38 mm depth provides a substantially larger impeller blade area, enabling airflow and pressure ratings that rival much larger frame sizes.

Key Performance Envelope. The series supports 12 VDC, 24 VDC, and 48 VDC input options, with speed variants typically ranging from 2,500 RPM to 9,000 RPM. At the high end, airflow reaches approximately 166 CFM (4.67 m³/min) with static pressure near 1.45 in H₂O (361 Pa)—figures comparable to premium industrial 9238 platforms. Lower-speed versions prioritize acoustic comfort, delivering around 80–125 CFM at noise levels in the 37–56 dBA range.

Construction & Reliability. Frames and impellers are typically molded from UL94V-0 rated PBT, balancing rigidity with flame resistance. Dual ball bearing systems are standard for long service life in continuous-duty applications, with some configurations offering IP55 or IP68 ingress protection for dust- and moisture-exposed environments.

Control & Integration. The platform accommodates PWM speed control, tachometer (FG) output, and rotation detection (RD) signals, allowing precise thermal modulation within server chassis, telecom cabinets, and industrial power supplies.

Typical Applications. LBMS9238-class fans are deployed in CCTV/NVR enclosures, automotive electronics, server racks, HVAC control panels, and medical or pharmaceutical thermal systems where a compact footprint and high static pressure are simultaneously required.