190mm EC backward curved centrifugal fan with PA66 impeller, IP55 rated, delivers 973m³/h airflow for factory heat dissipation and commercial air purification systems.
The LBMR9238 Series is a 92mm x 92mm x 38mm DC axial fan built for reliable cooling in demanding electronic and industrial systems. Its 9238 frame provides a larger depth for higher static pressure and airflow, making it suitable for power supplies, inverters, control cabinets, telecom equipment, chargers, and compact machines with airflow resistance. The series supports flexible DC voltage, speed, bearing, connector, and lead-wire options to balance cooling performance, noise, and service life. A balanced impeller and sturdy housing help ensure stable operation, low vibration, easy installation, and long-term durability. LB offers OEM customization for voltage, speed, airflow, noise, and bearing type. Contact us with your application requirements to select the right LBMR9238 configuration.
The LB LBMS1225 Series is a 120mm x 120mm x 25mm DC axial fan engineered for dependable cooling in electronic and industrial equipment. Its compact 12025 frame fits power supplies, control cabinets, telecom units, chargers, inverters, and other space-limited systems. The series offers flexible DC voltage, speed, bearing, connector, and lead-wire options to match airflow, noise, and service-life requirements. Balanced impeller design and a sturdy housing support stable performance, low vibration, and easy installation. Its 12025 form factor simplifies replacement and system integration, while consistent production and flexible options support OEM projects. LB provides customization for voltage, speed, airflow, noise, and bearing type. Contact us with your application details to select the right LBMS1225 configuration.
The LOBISONG LBE1225 Series is a 120mm x 120mm x 25mm DC axial fan designed for reliable cooling and air movement in compact electronic and industrial systems. Its 12025 frame size suits power supplies, control cabinets, communication equipment, chargers, inverters, and space-conscious applications. The series supports flexible DC voltage, speed, bearing, connector, and lead-wire configurations to meet different airflow, noise, and service-life requirements. Balanced impeller geometry and a durable frame help deliver stable performance, easy installation, and long-term operation. LOBISONG offers customized options for OEM projects, including performance and electrical options. Contact us with your voltage, speed, airflow, noise, and bearing requirements to select the right LBE1225 version.
Technical Description
Impeller Material | PA66 Engineering Plastic
Bearing Type| Ball Bearing
Duty Type| S1 Continuous Operation
Protection Class | IP55
Insulation Class | F
Operating Temperature | -25℃ ~ +60℃
Power Supply | 230V, 50/60Hz
Model| LBBE3G175-072PS-01
Impeller Diameter | 175mm
Shaft Power | 55W
Matched Motor Power | 55W
Speed | 2800 r/min
Air Flow(Max) | 536 m³/h

Key Features & Benefits
Backward Curved Centrifugal Design – PA66 Impeller – The backward curved impeller is constructed from high-strength PA66 engineering plastic. It delivers high static pressure with relatively low noise, perfectly suitable for kitchen exhaust scenarios where the fan needs to push airflow against grease filter and duct system resistance. PA66 material features excellent heat resistance, anti-grease and anti-aging performance. The lightweight impeller enables smooth, long-duration continuous running. Optimized backward curved blade profile reduces airflow turbulence and energy consumption, generating stable high-pressure airflow to efficiently discharge oily kitchen fume.
Multiple Performance Variants for Kitchen & Factory Ventilation – This 175mm EC centrifugal fan series provides three optional performance versions to satisfy different ventilation design requirements. The LBBE3G175-072PS-01 variant has 55W rated shaft power, operating at 2800 r/min with maximum airflow of 536 m³/h. Other available models: LBBE3G175-072PS-02 (85W /3300rpm, 742m³/h for factory ventilation) and LBBE3G175-072PS-03 (115W /4400rpm, 700m³/h for kitchen exhaust). System designers can select the proper model to balance airflow output, power draw and noise level for kitchen fume extraction and industrial ventilation projects.
IP55 Protection Grade – Rated IP55 protection against dust ingress and water splash. It shields the built-in EC motor and electronic drive components from oil mist, fine dust and splashing water. The sealed structure guarantees stable operation in greasy kitchen environments, making it ideal for range hood and kitchen ventilation equipment that continuously handles oil-laden air.
Class F Insulation & Wide Operating Temperature – Adopts Class F motor insulation to withstand temperature rise under continuous working load. The fan can reliably operate within ambient temperature range of -25℃ ~ +60℃, adapting to temperature fluctuation in kitchen and factory spaces. S1 continuous operation mode supports non-stop long-hour running for exhaust and ventilation systems.
Ball Bearing, Maintenance-Free Operation – Equipped with precision ball bearings for smooth rotation, low vibration and low friction loss. No regular lubrication or routine maintenance required, cutting downtime and lowering total cost of ownership over the product lifespan. Compact structure allows simple installation inside kitchen hood cabinets and easy integration into ventilation systems.
LBBE3G175 EC backward curved centrifugal fan with PA66 impeller features IP54/IP55 protection and Class F insulation for air purification & ventilation.
LOBISONG LBG1225 Series — 120×120×25 mm DC Axial Fan
The LOBISONG LBG1225 is a 120 mm × 120 mm × 25 mm DC axial fan on the slim-profile 12025 platform, positioned as a general-purpose, cost-sensitive entry within LOBISONG’s 1225 lineup—comparable to how the LBG1238 occupies the baseline tier of the 38 mm family. Its 25 mm depth enables installation in compact chassis where 38 mm-class fans will not fit, while retaining the universal 120 mm mounting pattern.
Performance. The LBG1225 accommodates 5 V, 12 V, 24 V, and 48 V DC inputs. Across the 12025 envelope, configurations typically span roughly 1,500–2,700 RPM, with airflow of approximately 54–99 CFM and static pressure from 0.07 in H₂O (17 Pa) up to 0.22 in H₂O (55 Pa) at the upper end. Acoustic output ranges from about 26 dB(A) at low-speed settings to the low 40s dB(A) at maximum speed, making the series suitable for noise-conscious compact equipment.
Construction. The fan uses a brushless DC motor with a plastic impeller and ball bearing construction for stable long-term rotation. Housings and impellers are molded from fiberglass-reinforced PBT rated UL94V-0 for flame retardancy. Ball-bearing life is commonly specified around 65,000 hours at 45 °C, and protection features on comparable 12025 platforms include polarity protection and auto-restart, with PWM and tachometer (FG) options available on selected builds.
Applications. Suited to computers, power supplies, control units, communication products, small cabinets, and compact OEM cooling systems where 25 mm depth and dependable airflow are required.
Note: LBG1225 voltage, speed, bearing, and protection ratings vary by specific part number and should be confirmed against LOBISONG’s official datasheet before design integration.
LOBISONG LBH1225 Series — 120×120×25 mm DC Axial Fan
The LOBISONG LBH1225 is a 120 mm × 120 mm × 25 mm DC axial fan built on the slim-profile 12025 platform. Compared with the 38 mm-deep 12038 family, the reduced 25 mm depth makes it a drop-in choice where chassis clearance is tight but a full 120 mm mounting pattern is still desired. The “LBH” designation places it in LOBISONG’s standard-duty slim line.
Performance. The LBH1225 supports common DC bus voltages—5 V, 12 V, 24 V, and 48 V—through the platform’s flexible input design. Across the 12025 envelope, typical configurations span roughly 2,000–3,400 RPM, with airflow in the 64–117 CFM range and static pressure from about 0.12 in H₂O (30 Pa) up to 0.39 in H₂O (97 Pa) at the higher-speed end. Broader platform data cites a wider airflow window of 76–151 CFM depending on model and speed. Acoustic output typically falls in the 35–48 dB(A) band, making the LBH1225 suitable for noise-sensitive compact equipment.
Construction. The fan uses a brushless DC motor with a plastic impeller and ball bearing structure for stable long-term rotation. Platform-comparable ball-bearing life reaches 60,000–70,000 hours, with some configurations rated for 65,000 hours at 45 °C. Housings and impellers are commonly molded from fiberglass-reinforced PBT, and PWM speed control and tachometer (FG) output are available on selected models.
Applications. Suited to computers, power supplies, control units, communication equipment, small cabinets, and compact OEM cooling systems where 25 mm depth and moderate-to-high airflow are required.
Note: LBH1225 voltage, speed, bearing, and protection ratings vary by specific part number and should be confirmed against LOBISONG’s official datasheet before design integration.
LOBISONG LBF1238-H Series — 120×120×38 mm DC Axial Fan
The LOBISONG LBF1238-H is the high-speed member of LOBISONG’s 12038 DC axial fan family, engineered for applications where standard airflow is insufficient and elevated static pressure is mandatory. The 120×120×38 mm frame preserves the universal 120 mm mounting pattern while the 38 mm depth accommodates a larger impeller and motor assembly than 25 mm-class fans.
Performance. “H” denotes the high-speed bin within the series. Platform-typical 12038 high-speed configurations span approximately 3,000–3,600 RPM, delivering airflow in the 119–184 CFM range and static pressure of 7.8–15 mmH₂O, with noise rising to the 44–53 dB(A) band. Higher-tier builds on this platform can reach beyond 4,000 RPM where maximum pressure head is required. Available DC voltages typically include 12 V, 24 V, and 48 V, matching telecom, server, and industrial power rails.
Construction. The fan uses a brushless DC external-rotor motor with dual ball bearing options rated for continuous duty; platform ball-bearing life is commonly specified at 50,000 hours at 25 °C, with premium industrial versions extending to 70,000 hours L10 at 40 °C. Housings and impellers are molded from UL94V-0 flame-retardant PBT, and IP54/IP68 ingress protection is available on selected configurations for dust- and moisture-exposed installations. Polarity protection and auto-restart are standard safeguards.
Applications. Suited to server chassis, telecom cabinets, power inverters, welding equipment, industrial drives, and dense electronic enclosures where a 120 mm footprint must overcome substantial system impedance.
Confirm voltage, speed, bearing, and IP rating against the specific LOBISONG part number before design integration.
LOBISONG LBG1238 Series — 120×120×38 mm DC Axial Fan
The LOBISONG LBG1238 series is a 120 mm × 120 mm × 38 mm DC axial fan built on the industry-standard 12038 platform. Within LOBISONG’s 12038 lineup, the “LBG” designation occupies a general-purpose tier—positioned as a baseline or broad-application offering alongside the mid-tier LBMD and high-speed LBF variants. Its engineering intent is straightforward: deliver dependable forced convection at the lowest practical cost for volume deployments.
Core Performance. The LBG1238 accepts the standard DC bus voltages of the 12038 class—12 V, 24 V, or 48 V—so it integrates directly with telecom, industrial, and IT power rails. Because “LBG” does not encode a fixed speed or pressure class, performance varies by part number. Within the broader 12038 envelope, configurations span roughly 1,950 RPM / 73 CFM / 0.13 in H₂O at the low end to 3,600 RPM / 158 CFM / 0.49 in H₂O at the high end, with intermediate tiers around 2,400–2,800 RPM and 0.24–0.32 in H₂O. This makes the LBG1238 a flexible selection: low-speed builds for acoustic-sensitive enclosures, and higher-speed builds where heatsink or filter impedance demands more pressure.
Construction & Durability. The fan uses a brushless DC external-rotor motor with PBT housing and impeller, UL94V-0 flame retardant and RoHS compliant. Bearing options follow the 12038 convention—dual ball bearings for continuous industrial duty, or sleeve/hydraulic variants for cost-driven, moderate-temperature deployments. Available protection and control features across the platform include thermal overload protection (TOP), reverse-polarity protection, auto-restart, and optional tachometer (FG) or PWM speed control.
Applications. The LBG1238 is suited to power supplies, inverters, control cabinets, telecom equipment, and general electronic enclosures where a standard 120 mm mounting pattern must provide reliable airflow at an economical cost point.
Note: Because “LBG1238” is a series-level designation, voltage, speed, airflow, bearing, and protection ratings must be verified against the specific LOBISONG part number and official datasheet before design integration.
LOBISONG LBMD1238 Series — 120×120×38 mm DC Axial Fan
The LOBISONG LBMD1238 series is a 120 mm × 120 mm × 38 mm DC axial fan on the widely used 12038 platform. The “LBMD” designation positions it as a mid-tier offering within LOBISONG’s 12038 lineup, sitting between standard-duty and high-speed variants and targeting applications that require a balanced trade-off between airflow, static pressure, and acoustic output.
Core Performance. The LBMD1238 typically accepts 12 V, 24 V, or 48 V DC inputs, accommodating common industrial and telecom power rails. Across the 12038 platform, mid-range configurations commonly operate in the 3,000–3,800 RPM band, producing roughly 137–174 CFM with static pressure in the range of 0.42–0.67 in H₂O (105–167 Pa). Higher-speed tiers can push toward 205 CFM and 0.94 in H₂O (235 Pa) at around 4,500 RPM, though noise rises accordingly to the low 60s dB(A). This performance envelope makes the LBMD1238 suitable for forcing air through moderately dense heatsinks, filters, and perforated panels without the acoustic penalty of full high-speed operation.
Construction & Durability. The fan uses a brushless DC external-rotor motor for long service life and low electrical interference. Bearing options typically include dual ball bearings for continuous industrial duty and sleeve or hydraulic variants for cost-sensitive, lower-temperature deployments; NMB ball bearings are commonly rated around 50,000 hours at 40 °C. Housings and impellers are molded from UL94V-0 flame-retardant PBT, providing dimensional stability and flame resistance. Protection features often include thermal overload protection (TOP), reverse polarity protection, and auto-restart, while PWM speed control and tachometer (FG) output are available as options for closed-loop thermal management.
Applications. The LBMD1238 is suited to telecom cabinets, power inverters, industrial control panels, server chassis, and dense electronic enclosures where a standard 120 mm mounting pattern must deliver reliable mid-to-high-pressure forced convection at moderate acoustic levels.
Note: LBMD1238 voltage, speed, airflow, bearing, and protection ratings vary by specific part number and should be confirmed against LOBISONG’s official datasheet before final design integration.
LOBISONG LBH1238 Series — 120×120×38 mm DC Axial Fan
The LOBISONG LBH1238 series is a 120 mm × 120 mm × 38 mm DC axial fan built on the widely adopted 12038 platform, combining a compact square footprint with a 38 mm depth to generate meaningful static pressure in space-constrained enclosures. The “LBH” designation places it within LOBISONG’s standard-duty 12038 family, alongside the high-speed LBF1238-H variant.
Core Performance. The LBH1238 accepts common DC bus voltages—typically 12 V, 24 V, or 48 V—allowing direct integration with industrial power architectures. Across the 12038 platform, speed ranges from roughly 2,000 to 3,800 RPM, producing airflow of approximately 80–154 CFM with static pressure sufficient to push through moderately dense heatsinks, filters, and perforated panels. Lower-speed tiers prioritize acoustic comfort, while higher-RPM configurations trade noise for thermal headroom.
Construction & Durability. The fan uses a brushless DC external-rotor motor for long service life and low electrical interference. Bearing options include dual ball bearings for continuous industrial operation and sleeve or hydraulic variants for cost-sensitive, lower-temperature applications. Housings and impellers are typically molded from UL94V-0 flame-retardant PBT, with some configurations offering IP-rated ingress protection for dusty or humid environments. PWM and tach (FG) signal options are commonly available across the 12038 platform for closed-loop speed control.
Applications. The LBH1238 is suited to telecom cabinets, power supplies, inverters, industrial control panels, and dense electronic chassis where a standard 120 mm mounting pattern must deliver reliable forced convection at moderate-to-high pressure.
Note: Voltage, speed, airflow, bearing, and protection ratings for the LBH1238 vary by configuration and should be confirmed against LOBISONG’s official datasheet for the specific part number.
The LOBISONG LBMR1225 Series is a DC axial fan in the 120mm x 120mm x 25mm form factor, designed for compact thermal management where space is limited but reliable airflow is essential. The "R" designation typically indicates a reduced-thickness 25mm profile within the LOBISONG 120mm lineup.
Key Specifications (Typical 12025 Range):
Airflow: 60 – 110 CFM (varies by speed variant)
Static Pressure: 0.10 – 0.28 in H₂O
Speed: 1,800 – 3,500 RPM
Noise Level: 25 – 47 dB(A)
Voltage Options: 12VDC, 24VDC, and 48VDC
Features & Construction:
The LBMR1225 series typically utilizes PBT (Polybutylene Terephthalate) with fiberglass reinforcement for both frame and impeller, offering UL94V-0 flame retardancy and excellent dimensional stability. Ball bearing and sleeve bearing options are available, with ball bearing variants providing superior longevity in high-temperature environments. Common features include Auto-Restart upon locked rotor detection, reverse polarity protection, and options for Speed Sensor (Tach) output, PWM control, and Locked Rotor Alarm Signal.
Applications:
Suited for compact electronic enclosures, power supply units (PSU) , network switches and routers, LED lighting fixtures, and consumer electronics cooling. The 25mm thickness makes it ideal for space-constrained installations where a standard 38mm fan would not fit, while still delivering dependable axial airflow.
Reliability:
With ball-bearing construction, typical L10 lifespan is rated at 65,000 hours or more at 45°C, ensuring dependable long-term operation in continuous-duty applications. Operating temperature range is typically -10°C to +70°C.
Note: Specific performance figures vary by individual model within the LBMR1225 series. Consult the exact part number datasheet for precise specifications.
LOBISONG LBF1238-H Series — 120×120×38 mm DC Axial Fan
The LOBISONG LBF1238-H series is a 120 mm × 120 mm × 38 mm DC axial fan engineered for demanding thermal management where high airflow and static pressure are paramount. This “H” (High-Speed) variant is built around a 12038 platform, a form factor widely adopted in industrial and server cooling for its ability to move substantial volumes of air through dense component arrays.
Core Performance. The LBF1238-H is designed to operate across common DC bus voltages—typically 12 V, 24 V, or 48 V—making it compatible with a broad range of power architectures. In its high-speed configuration, this frame size can achieve rotational speeds exceeding 3,000 RPM, delivering airflow in the range of 110–150 CFM and static pressure up to approximately 9–10 mmH₂O. This combination of flow and pressure allows the fan to overcome the impedance of heatsinks, filters, and densely packed enclosures without stalling.
Construction & Durability. The fan employs a brushless DC external-rotor motor, ensuring long operational life and low electrical noise. Bearing options typically include dual ball bearings for high-temperature environments and extended service life (often rated 50,000–70,000 hours), as well as sleeve-bearing variants for cost-sensitive, lower-temperature applications. The housing and impeller are commonly molded from UL94V-0-rated PBT or die-cast aluminum, providing flame retardancy and resistance to deformation under thermal cycling. Many industrial-grade 12038 fans further offer IP54 or IP68 ingress protection for exposure to dust and moisture.
Applications. The LBF1238-H is suited to telecom cabinets, power inverters, industrial drives, welding equipment, medical imaging systems, and high-density computing chassis—anywhere a compact 120 mm footprint must deliver reliable, high-pressure forced convection.
Note: Exact voltage, speed, airflow, and bearing specifications for the LBF1238-H should be confirmed against LOBISONG’s official datasheet, as the 12038 platform encompasses multiple performance tiers within the same series.
The LOBISONG LBG1238 Series is a DC axial fan in the 120mm x 120mm x 38mm form factor, designed for applications requiring robust and reliable thermal management. It shares the standard 12038 footprint with the LBMD series but is positioned as a general-purpose cooling solution for moderate-performance needs.
Key Specifications (Typical 12038 Range):
Airflow: 70 – 120 CFM (varies by speed variant)
Static Pressure: 0.13 – 0.47 in H₂O
Speed: 1,900 – 3,600 RPM
Noise Level: 33 – 49 dB(A)
Voltage Options: 12VDC, 24VDC, and 48VDC
Features & Construction:
The LBG1238 series typically utilizes PBT (Polybutylene Terephthalate) for both frame and impeller, offering UL94V-0 flame retardancy and resistance to high temperatures and corrosion. Ball bearing systems are standard, contributing to stable operation and extended service life. Many variants incorporate Thermal Overload Protection (TOP) , with options available for Speed Sensor (Tach) output and PWM control.
Applications:
Suited for industrial control cabinets, power supply units (PSU), network equipment, HVAC systems, and general electronic enclosure cooling. The 38mm thickness provides higher static pressure capability than standard 25mm fans, making it effective in moderately restrictive airflow environments.
Reliability:
With ball-bearing construction, typical L10 lifespan is rated at 70,000 hours or more, ensuring dependable long-term operation in continuous-duty applications.
Note: Specific performance figures vary by individual model within the LBG1238 series. Consult the exact part number datasheet for precise specifications.
The LOBISONG LBMD1238 Series is a high-performance DC axial fan engineered for demanding thermal management applications. Featuring a robust 120mm x 120mm x 38mm frame, this fan delivers exceptional cooling efficiency in a compact form factor.
Key Specifications:
Features & Benefits:
The LBMD1238 incorporates advanced protective features, including Thermal Overload Protection (TOP) and options for PWM Control and Speed Sensor (Tach) output. Its construction utilizes PBT (Polybutylene Terephthalate) for both frame and blades, ensuring resistance to high temperatures and corrosion.
Applications:
Ideally suited for server and data center cooling, telecom cabinet ventilation, industrial control systems, and HVAC equipment. The fan's high static pressure makes it effective in environments with dense componentry or restrictive airflow paths.
With a proven lifespan of up to 70,000 hours at 25°C, the LBMD1238 Series guarantees reliable, long-term performance.
LOBISONG LBH1238 Series — 120mm × 120mm × 38mm DC Axial Fan
The LOBISONG LBH1238 Series is a high-performance DC axial fan engineered for demanding thermal management applications. With a standard 120mm × 120mm × 38mm frame, this fan delivers exceptional airflow while maintaining a compact footprint suitable for server racks, power supplies, telecom cabinets, and industrial control systems.
Available in 12V, 24V, and 48V DC configurations, the LBH1238 Series offers flexible integration across diverse power environments. The fan utilizes a precision-engineered brushless DC motor with dual ball bearing construction, ensuring reliable operation and an extended service life of up to 50,000 hours at 40°C. Sleeve bearing options are also available for cost-sensitive applications.
Performance-wise, the LBH1238 achieves airflow rates ranging from approximately 80 to 220 CFM depending on the speed variant selected, with static pressure reaching up to 20.36 mmH₂O in high-speed models. Noise levels are carefully balanced across the lineup, ranging from a quiet 42.5 dBA in low-speed versions to 57.5 dBA in ultra-high-speed configurations. The fan supports optional PWM speed control, FG tachometer output, and reverse polarity protection for advanced system monitoring and safety.
The impeller and frame are constructed from durable PBT material with 30% glass fiber reinforcement, offering excellent dimensional stability and resistance to vibration and temperature extremes. Operating temperature ranges from -30°C to +75°C for ball bearing models, making the LBH1238 suitable for both commercial and industrial deployments.
With its robust construction, versatile voltage options, and reliable performance, the LOBISONG LBH1238 Series represents a dependable cooling solution for engineers and system integrators seeking a balance of airflow, longevity, and acoustic comfort.
The LOBISONG LBMR1238 Series is a 120mm x 120mm x 38mm DC axial fan engineered for dependable thermal management in demanding equipment. Its compact yet deep frame delivers strong static pressure and steady airflow, making it ideal for enclosures, control cabinets, power supplies, telecom racks, industrial electronics, and other space-limited systems. The fan is built with a precision-balanced impeller and a durable motor to ensure smooth operation, low vibration, and long service life. It supports quiet cooling, helping reduce acoustic noise while maintaining reliable heat dissipation. With standard 120mm mounting, it is easy to install and replace in existing cooling systems. The LBMR1238 Series is suitable for continuous-duty applications where stable performance and energy efficiency matter. It suits OEM and maintenance projects. Compact, durable, and efficient, it is a reliable choice for many cooling needs.