EC Motor Configuration: Handled electronically, commutation is the motor architecture behind a backward-curved fan that can be tied into an external control arrangement.
The Lebisen 225FLW2 and 225FLW3 vortex centrifugal fans adopt durable iron backward-curved blades to achieve high air delivery efficiency for purification and industrial ventilation scenarios. Featuring solid metal impellers with dynamic balance treatment, these fans maintain stable airflow and static pressure while lowering vibration and running noise. Equipped with external rotor motors and built-in thermal protection, they are capable of long-duration continuous operation in demanding working environments. The two models provide differentiated air volume and pressure parameters to fit clean benches, dust collection equipment, cabinet heat dissipation and cleanroom air circulation systems. Widely selected by equipment manufacturers, engineering integrators and global bulk buyers, Lebisen centrifugal fans undergo rigorous performance inspections to deliver dependable and cost-effective air power solutions for electronics, pharmaceutical and factory air treatment industries.
The 250FLW2 and 250FLW3 vortex centrifugal fans feature sturdy iron backward-curved blades optimized for high-efficiency air delivery in industrial ventilation and purification systems. Designed with robust all-metal construction and dynamically balanced impellers, these blowers generate stable airflow and proper static pressure while reducing vibration and operational noise. Powered by external rotor motors with built-in thermal protection, they support extended continuous operation under heavy working conditions. The two models deliver different air volume and pressure outputs to accommodate clean benches, dust removal units, cabinet cooling and cleanroom air circulation. Preferred by equipment makers, system integrators and bulk international purchasers, this backward-curved centrifugal fan series passes strict performance testing to supply reliable, long-lasting air power solutions for electronics, pharmaceutical and workshop air treatment applications.
The 175FLW2 all-metal turbine centrifugal fan is equipped with robust iron blades and available in two core model specifications, R2E175-AC77-15 and R2E175-AC77-05. Built with a full metal structure and dynamically balanced impellers, this centrifugal fan delivers consistent high-pressure airflow with low vibration and quiet continuous operation. Adopting mature external rotor motor technology, it features reliable heat resistance and overload protection to support long-cycle running in industrial environments. Widely adopted for air purification equipment, clean benches, cabinet ventilation, equipment heat dissipation and small air circulation systems, it meets diverse static pressure and air volume requirements. Suitable for equipment manufacturers, engineering integrators and bulk overseas buyers, this fan undergoes strict quality inspection to provide stable, cost-effective air power solutions for purification, electronics and light industrial ventilation projects.
Lebisen 280FLW2 and 280FLW3 all-metal vortex centrifugal fans are heavy-duty turbine blowers fitted with sturdy iron blades, engineered for stable high-static air supply in air purification and industrial ventilation projects. Built with full metal housing and precision dynamically balanced iron impellers, these FLW series fans adopt external rotor motor structure, delivering steady airflow, low vibration and quiet continuous running without extra volute assembly. Featuring reliable ball bearings and thermal protection, the units maintain consistent performance under long-hour operation and adapt well to clean benches, purification units, dust removal pipelines, equipment cooling and industrial air circulation systems. Available in two model variants for different air volume and pressure requirements, the Lebisen 280FLW2/280FLW3 purification turbine fans support flexible installation for system integrators and bulk buyers. Rigorously tested for industrial stability, this series serves cleanroom, pharmaceutical, electronics and workshop air treatment scenarios, offering durable, cost-effective centrifugal air power solutions for global B2B purchasers of ventilation and purification components.
The Lebisen 280FLW2 and 280FLW3 vortex centrifugal fans are premium all-metal purification turbine fans equipped with robust iron blades, purpose-built to deliver reliable high-pressure airflow for industrial air purification and ventilation applications. Constructed with full metal frames and dynamically balanced iron impellers, these FLW series centrifugal blowers adopt mature external rotor motor design to realize stable air output, minimized vibration and low noise during nonstop long-time operation. Integrated with high-quality bearings and overheat protection, they sustain consistent working performance in demanding industrial environments. The two models cater to differentiated air volume and static pressure demands, supporting versatile mounting methods to match clean benches, dust collection systems, industrial equipment cooling, cleanroom air circulation and other air treatment facilities. Widely supplied to system integrators, engineering contractors and bulk global buyers, Lebisen 280FLW2/280FLW3 turbine fans undergo strict performance testing, providing durable, economical air power solutions for electronics, pharmaceutical, food processing and workshop purification industries.
FLW2/FLW3 Turbo Centrifugal Fan Series: Covers 133, 175, 180, 190, 220, 225, 250, and 280 size designations for industrial air-movement projects.
Industrial Silent-Type Fan Family: The series is positioned for controlled centrifugal airflow in compatible equipment and ventilation assemblies.
Multi-Size Selection for Equipment Integration: Different size designations help buyers identify a suitable centrifugal fan reference for their installation.
Reference-Based Procurement Support: Confirm the exact FLW2 or FLW3 model, mounting arrangement, and equipment requirements before ordering.
W2E250 HK38/HH86 Axial Fan Series for Industrial Cooling: Nine HL06 variants and two HH86 references provide direct airflow for cabinets, machinery enclosures, and ventilation systems.
Outer-Rotor Motor with Copper Windings and Bearing Support: The shared motor construction supports stable operation in continuous-duty industrial air-movement applications.
220V/380V and 2450/2600 RPM Series Coverage: Family-level electrical and speed options support equipment matching across different installation requirements.
CAD and Technical Documentation Available: Engineering files, certification information, and technical references support selection, integration, and replacement planning.
W2E200 HK38/HH86 Axial Fan Series for Industrial Cooling: Seven model references provide direct airflow for cabinets, equipment enclosures, and ventilation systems.
Outer-Rotor Motor with Copper Windings and Bearing Support: The shared motor construction supports stable operation in continuous-duty industrial air-movement applications.
220V/380V and 2450/2600 RPM Series Coverage: Family-level electrical and speed options support equipment matching across different installation requirements.
CAD and Technical Documentation Available: Engineering files, certification information, and technical references support selection, integration, and replacement planning.
R2E280 Centrifugal Fan Series for Industrial Ventilation: R2E280-AE52-17 and R2E280-AE52-05 provide controlled airflow for equipment cooling and air-handling applications.
Outer Rotor Motor with Copper Windings: The series combines an outer-rotor motor design, copper winding, and bearing support for stable industrial air movement.
220V/380V Fan Range for Equipment Integration: Family-level electrical and airflow ranges support selection for cabinets, drying equipment, and ventilation assemblies.
CAD and Technical Documentation Available: Drawings, performance information, and application support help buyers confirm mounting and airflow requirements.
Outer-Rotor Brushless Axial Fan for Industrial Cooling: ZN050-VDL.4I.V7P1 supports reliable air movement for equipment enclosures and ventilation systems.
Pure Copper Winding with Imported Bearings: The motor assembly is designed for smooth rotation and lower-maintenance operation in continuous-duty applications.
CAD and Technical Documentation Available: Engineering files, certification information, and technical references support design review and equipment integration.
Model-Specific Support for B2B Sourcing: ZN050-VDL.4I.V7P1 supports industrial procurement, replacement planning, and application-based technical coordination.
Inverter Cabinet Top Fan Series for Equipment Cooling: RH45M-VDK.4F.1R and RH45M-4EK.4I.1R support cabinet-top ventilation and direct enclosure airflow.
Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearing support help maintain stable operation in continuous-duty cooling applications.
CAD and Technical Documentation Available: Installation references, certification information, and technical data support engineering selection and equipment integration.
Two-Reference Support for Replacement Projects: RH45M model references support cabinet fan replacement, maintenance sourcing, and application-specific selection.
RH40M Backward Curved Centrifugal Fan Series: Four model references support controlled airflow for drive systems, cabinets, and equipment enclosures.
Brushless Outer Rotor Motor Construction: Copper windings and bearing-supported motor assemblies provide a stable basis for continuous-duty ventilation applications.
Engineering Documentation Available: CAD drawings, certification references, and technical documentation support selection and installation planning.
Multi-Reference Support for Industrial Replacement: RH40M-4EK.4F.1R, RH40M-4I.1R, RH40M-4DK.4F.1R, and RH40M-4DK.4C.1R support model-based procurement matching.
RH28M Centrifugal Fan Series for Equipment Cooling: Three model references support controlled airflow for drive systems, cabinets, and machinery enclosures.
Brushless Outer Rotor Motor Construction: Copper windings and bearing-supported motor assemblies provide a stable basis for continuous-duty ventilation applications.
CAD and Compliance Documentation Available: Technical references, certifications, and installation documentation support engineering selection and integration planning.
Multi-Reference Support for Replacement Projects: RH28M-2DK.3F.1R, RH28M-2EK.3F.1R, and RH28M-2DK.3F.2R support model-based procurement matching.
115V Inverter Centrifugal Fan for Equipment Cooling: R2E220-AA44-23 supports controlled airflow in compatible inverter systems, cabinets, and machinery enclosures.
100W–150W Centrifugal Fan Series: The stated power range supports selection across related R2E220 inverter cooling applications.
Controlled Air Delivery for Enclosed Equipment: The centrifugal fan configuration is suited to equipment requiring guided airflow through a defined ventilation path.
Model-Based Replacement Selection: Confirm the R2E220-AA44-23 reference, 115V supply, mounting position, and airflow direction before ordering.
400/480V Axial Fan Series for Spindle Motor Cooling: M2D068 BF, CF, and DF references support direct airflow for 1PH7 motor and drive equipment applications.
Brushless Outer Rotor Motor Construction: Pure copper windings and precision bearing support help maintain stable airflow in continuous-duty industrial installations.
50Hz Industrial Fan Series with CE Documentation: Technical parameter sheets, performance references, and CAD drawings support model selection and equipment integration.
Multi-Reference Cooling Fan for Replacement Projects: Three M2D068 references support maintenance matching, spindle motor cooling, and application-specific sourcing.