products_11, products_11, /products
Inquiry
Inquiry

Products

K2D250-AH06-06 K2D250-RA32-10 SK 3244.140 400V Centrifugal Fan

K2D250-AH06-06 K2D250-RA32-10 SK 3244.140 400V Centrifugal Fan

400V Centrifugal Fan Kit for Industrial Equipment Cooling: K2D250-AH06-06, K2D250-RA32-10, and SK3244.140 support controlled airflow in cabinets and machinery enclosures.

Brushless Outer Rotor Motor Construction: Pure copper windings and precision bearing support provide stable operation for continuous ventilation applications.

CE and CCC Compliant Fan Series: CAD drawings, technical data, and installation references support engineering selection and equipment integration.

Shared Reference Kit for Replacement Projects: Multiple identifiers help support procurement matching, maintenance planning, and application-specific sourcing.

G4E280-BC23-05 Fan 6SL3362-0AG00-0AA1 RG28P-4EK.41.1R

G4E280-BC23-05 Fan 6SL3362-0AG00-0AA1 RG28P-4EK.41.1R

280mm Turbine Centrifugal Fan for Drive and Equipment Cooling: G4E280-BC23-05 references 6SL3362-0AG00-0AA1 and RG28P-4EK.41.1R for controlled industrial airflow.

Centrifugal Airflow with Durable Material Construction: Galvanized steel impeller and die-cast aluminum housing support directional air delivery in equipment enclosures.

230V 50/60Hz Fan with IP44 Protection: Pure copper windings, imported bearings, CE/CCC compliance, and technical documentation support equipment integration.

Replacement and Installation Support: CAD drawings, parameter data, and application-specific sourcing support assist drive replacement and mechanical matching.

G2E120-AR77-01 G2E120-CR21-01 G2E120-AR77-23 G2E120-CR21-13 AC Single Inlet Centrifugal Fan

G2E120-AR77-01 G2E120-CR21-01 G2E120-AR77-23 G2E120-CR21-13 AC Single Inlet Centrifugal Fan

120mm Single Inlet Centrifugal Fan Series: Four G2E120 AR77 and CR21 models support controlled airflow for cabinets, equipment enclosures, and industrial ventilation.

Durable Galvanized Steel and Die-Cast Aluminum Construction: A steel impeller and aluminum housing support robust mechanical integration for industrial equipment.

IP44 and Class B Insulation Series: IEC, EN, CE, and CCC compliance references support engineering selection and equipment documentation.

Wide Environmental Coverage for Equipment Cooling: Horizontal-shaft installation, internal thermal overload protection, and -40°C to +80°C conditions support varied industrial applications.

D2E160-AH01-17 D2E160-AH02-15 Inverter Fan 6SL3362-0AF01-0AA1

D2E160-AH01-17 D2E160-AH02-15 Inverter Fan 6SL3362-0AF01-0AA1

Single-Phase 230V Axial Cooling Fan Series: Three related references support inverter drive cooling, electrical cabinets, and industrial ventilation systems.

Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearing support help maintain smooth airflow in continuous-duty applications.

230V/50–60Hz Series with Complete Electrical References: Technical data, wiring information, and CAD drawings support equipment matching and installation planning.

Inverter Drive Replacement Fan Range: D2E160 and 6SL3362 references support maintenance, replacement, and application-specific sourcing requirements.

D2D160-DE02-11 D2D160-CE02-11 D2D160-BE02-11 D2D160-BE02-12 D2D160-BE02-14 Fans

D2D160-DE02-11 D2D160-CE02-11 D2D160-BE02-11 D2D160-BE02-12 D2D160-BE02-14 Fans

Turbine Centrifugal Fan Series for Industrial Cooling: Five D2D160 models deliver controlled airflow for cabinets, machinery enclosures, and long-distance air delivery.

Dual Inlet and Dual Outlet Airflow Structure: Multi-channel intake and directional outlet paths support concentrated airflow in confined equipment and ventilation systems.

Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearing support help maintain stable operation during continuous-duty applications.

Wide Electrical and Temperature Coverage: Single- or three-phase, 230V/400V, 50/60Hz operation and -25°C to +90°C conditions support varied industrial installations.

D2D146-BG03-13&14&15&16&17&37 400V Centrifugal Fan

D2D146-BG03-13&14&15&16&17&37 400V Centrifugal Fan

400V Centrifugal Fan Series for Industrial Cooling: Six D2D146-BG03 models support controlled airflow in equipment cabinets, machinery enclosures, and ventilation assemblies.

Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearings support smooth, stable operation in continuous-duty applications.

CE-Compliant Fan Series for Engineering Projects: CAD drawings, technical parameter sheets, and installation references support equipment matching and layout planning.

Wide Temperature Range for Demanding Environments: The series is specified for -40°C to +80°C operating conditions in applicable industrial ventilation systems.

D2E133-AM47-73 D2E133-AM47-71 D2E133-AM47-01 D2E133-AM47-23 AC Double Inlet Centrifugal Fan

D2E133-AM47-73 D2E133-AM47-71 D2E133-AM47-01 D2E133-AM47-23 AC Double Inlet Centrifugal Fan

230V Double Inlet Centrifugal Fan Series: Four related models support airflow for industrial equipment, cabinet cooling, and ventilation assemblies.

Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearings support stable operation in continuous-duty applications.

CE-Compliant Fan Series for Equipment Integration: Technical data, performance curves, wiring references, and CAD drawings support selection and installation planning.

Wide Operating Range for Industrial Ventilation: 50/60Hz operation, a 1500–2400 RPM series range, and -25°C to +60°C working conditions support varied equipment applications.

A4E300-AS72-01 Axial Fan, 230V, 300mm A4E300-AA01-60&01&48

A4E300-AS72-01 Axial Fan, 230V, 300mm A4E300-AA01-60&01&48

A4E300-AS72-01 230V 300mm Axial Fan: Designed for direct airflow in compatible equipment enclosures, cabinet openings, and ventilation positions.

Model-Based Equipment Matching: The A4E300-AS72-01 reference and related A4E300-AA01-60/01/48 designation support replacement identification.

Direct Airflow for Enclosure Ventilation: Suitable for applications where air needs to move through a panel, machine housing, or defined ventilation passage.

Installation Selection Reference: Confirm the 230V supply, 300mm size, mounting layout, electrical connection, and airflow direction before ordering.

A4E300-AA01-60 A4E300-AT16-11 A4Q300-BN01-05 A4E300-AE20-06 Metal Blades

A4E300-AA01-60 A4E300-AT16-11 A4Q300-BN01-05 A4E300-AE20-06 Metal Blades

Industrial AC Fan Series for Equipment Cooling: Four related models provide direct airflow for cabinets, machinery enclosures, and industrial ventilation positions.

Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearing support help maintain stable airflow in continuous-duty applications.

IP44 Protected Series with Compliance References: CE and UKCA documentation, technical parameter sheets, and CAD drawings support engineering selection and installation planning.

Multi-Model Support for Industrial Projects: The series includes four model references for replacement, equipment integration, and application-specific sourcing requirements.

A4D300-AS34-06 A4D300-AS34-02 A4D300-AS34-11 400V 68/90W Fans

A4D300-AS34-06 A4D300-AS34-02 A4D300-AS34-11 400V 68/90W Fans

400V AC Fan Series for Industrial Equipment Cooling: Three related models provide direct airflow for cabinets, machinery enclosures, and ventilation systems.

Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearing support help maintain stable airflow in continuous-duty applications.

IP44 Protected Series with Compliance References: CE and UKCA documentation, technical parameter sheets, and CAD drawings support engineering selection and installation planning.

68/90W Fan Family for Equipment Matching: A4D300-AS34 series models support replacement, industrial integration, and application-specific sourcing requirements.

A2E250-AJ40-08 A2E250-AM06-01 A2E250-AL06-11 A2E250-AL08-12 A2E250-AE65-01 AC Axial Fan

A2E250-AJ40-08 A2E250-AM06-01 A2E250-AL06-11 A2E250-AL08-12 A2E250-AE65-01 AC Axial Fan

AC Axial Fan Series for Industrial Equipment Ventilation: Five related models provide direct airflow for cabinets, machinery enclosures, and industrial cooling positions.

Brushless Outer Rotor Motor Construction: Pure copper windings and imported precision bearing support help maintain smooth operation in continuous-duty ventilation tasks.

IP44 Protected Fan Series with Technical References: Performance curves and wiring diagrams support selection, equipment matching, and installation planning.

Multi-Model Support for Industrial Projects: The series includes five model references for replacement, equipment integration, and application-specific sourcing needs.

A2D300-AD20-49 AC380V Axial Cooling Fan

A2D300-AD20-49 AC380V Axial Cooling Fan

AC380V Axial Cooling Fan for Industrial Ventilation: A2D300-AD20-49 supports direct airflow in equipment enclosures, electrical cabinets, and industrial cooling positions.

Pure Copper Motor Winding Design: The motor assembly uses copper winding material to support regular industrial ventilation and thermal-management duties.

Brushless Outer Rotor Motor Structure: Precision bearing support and a direct axial airflow layout help provide stable operation in applicable equipment environments.

Technical Selection Reference: Confirm the model number, electrical supply, mounting layout, and airflow direction against the relevant equipment documentation before installation.

A2D250‑AD26‑05 & W2D250 Series Industrial Axial Cooling Fan

A2D250‑AD26‑05 & W2D250 Series Industrial Axial Cooling Fan

Industrial Axial Cooling Fan Series for Equipment Ventilation: Pure copper motor windings and direct airflow support cooling in machinery enclosures and industrial equipment.

Brushless Outer Rotor Motor Design: A permanent-magnet motor configuration and precision bearing support help provide stable airflow for continuous ventilation tasks.

Multi-Model Fan Selection for Industrial Projects: Seven listed model references support equipment matching when buyers confirm the required installation and operating data.

Technical Documentation for Installation Planning: Parameter sheets and CAD drawings help users check mounting positions, equipment openings, and connection layouts before selection.

A2D250-AA02-02 A2D250-AA02-01 AC400V Inverter Fan

A2D250-AA02-02 A2D250-AA02-01 AC400V Inverter Fan

AC400V Inverter Cooling Fan for Industrial Drive Systems: A2D250-AA02-02 and A2D250-AA02-01 support airflow management in inverter enclosures and motor control equipment.

Dual Model Reference for Equipment Matching: Two listed models share the confirmed AC400V inverter fan specification for industrial replacement and maintenance planning.

Direct Airflow for Power Electronics Cooling: Suitable for cabinet ventilation, variable-speed drive cooling, and equipment enclosures requiring a defined air path.

Technical Selection Reference: Confirm model identity, installation dimensions, electrical supply, and airflow direction against the existing equipment before replacement.

8.3 Inch 210mm Axial Cooling Fan 400V 0.21A 60W 2800RPM 580m³&h Spindle Motor Cooling Fan A2D210-AB10-05 M2D068-CF Industrial Servo Motor Axial Fan

8.3 Inch 210mm Axial Cooling Fan 400V 0.21A 60W 2800RPM 580m³&h Spindle Motor Cooling Fan A2D210-AB10-05 M2D068-CF Industrial Servo Motor Axial Fan

210mm Axial Cooling Fan for Motor Equipment: 400V input, 60W rated power, 2800 RPM operation, and 580 m³/h airflow for industrial cooling positions.

A2D210-AB10-05 and M2D068-CF Fan Series: Two model references using the same confirmed 8.3-inch axial fan specifications for equipment matching.

Pure Copper Motor Winding Design: Direct axial airflow and precision bearing support for smooth operation in motor housings and ventilated enclosures.

Technical Selection Reference: Confirm the model, electrical supply, mounting dimensions, and required airflow direction against the applicable equipment drawing before installation.

A2D200-AA02-01 200mm 230&400V 3-Phase AC Axial Fan, 70W 3150RPM, Siemens Spindle Servo Motor Cooling Replacement

A2D200-AA02-01 200mm 230&400V 3-Phase AC Axial Fan, 70W 3150RPM, Siemens Spindle Servo Motor Cooling Replacement

200mm Axial Cooling Fan for Motor Systems: A2D200-AA02-01 with 230/400V three-phase AC input, 70W rated power, and 3150 RPM operation.

Siemens Spindle and Servo Motor Cooling Replacement: Direct axial airflow for motor housings, machine enclosures, and industrial drive ventilation positions.

Pure Copper Motor Winding Design: Compact axial fan construction with smooth-running bearing support for equipment cooling applications.

Technical Selection Reference: Confirm model, electrical rating, mounting dimensions, and airflow direction against the applicable equipment drawing before replacement.

6.3 Inch 160mm Axial Cooling Fan 400V 0.15A 44W 2800RPM 250³&h Spindle Motor Cooling Fan A2D160-AB22-05 Industrial Servo Motor Axial Fan

6.3 Inch 160mm Axial Cooling Fan 400V 0.15A 44W 2800RPM 250³&h Spindle Motor Cooling Fan A2D160-AB22-05 Industrial Servo Motor Axial Fan

160mm Axial Cooling Fan for Motor Equipment: 400V operation, 44W rated power, and 250 m³/h airflow for spindle motor and servo motor cooling.

A2D160-AB22-05 Industrial Axial Fan: 2800 RPM operating speed and a compact 6.3-inch frame for equipment housings and ventilated enclosures.

Precision Bearing Motor Cooling Fan: Pure copper winding motor and high-density bearing support for smooth rotation and controlled operating noise.

Technical Selection Support: Confirmed electrical data and CAD dimensional drawings help engineering teams check fitment for motor and cabinet cooling applications.

2580 28080 External Rotor Axial Fan, Motor Cabinet Cooling Fan 380V, High Temperature Resistant Metal

2580 28080 External Rotor Axial Fan, Motor Cabinet Cooling Fan 380V, High Temperature Resistant Metal

External Rotor Axial Fan for Cabinet Cooling: Pure copper winding motor and straight-through axial airflow for industrial equipment ventilation.

Precision Bearing Cooling Fan: High-density wear-resistant bearing construction supports smooth rotation, controlled vibration, and lower operating noise.

380V Axial Fan Series for Equipment Matching: Multiple model options, technical parameter sheets, and CAD dimensional drawings support practical selection and installation planning.

Metal Axial Ventilation Fan for Industrial Applications: Suitable for motor cabinets, commercial ventilation equipment, machinery cooling, tunnels, agricultural facilities, and factory installations.