a2d200-aa02-01-200mm-230/400v-3-phase-ac-axial-fan-70w-3150rpm-siemens-spindle-servo-motor-cooling-replacement, a2d200-aa02-01-200mm-230/400v-3-phase-ac-axial-fan-70w-3150rpm-siemens-spindle-servo-motor-cooling-replacement, /ac-cooling-fan
Inquiry
a2d200-aa02-01-200mm-230/400v-3-phase-ac-axial-fan-70w-3150rpm-siemens-spindle-servo-motor-cooling-replacement, a2d200-aa02-01-200mm-230/400v-3-phase-ac-axial-fan-70w-3150rpm-siemens-spindle-servo-motor-cooling-replacement, 
Inquiry

A2D200-AA02-01 200mm 230&400V 3-Phase AC Axial Fan, 70W 3150RPM, Siemens Spindle Servo Motor Cooling Replacement

200mm Axial Cooling Fan for Motor Systems: A2D200-AA02-01 with 230/400V three-phase AC input, 70W rated power, and 3150 RPM operation.

Siemens Spindle and Servo Motor Cooling Replacement: Direct axial airflow for motor housings, machine enclosures, and industrial drive ventilation positions.

Pure Copper Motor Winding Design: Compact axial fan construction with smooth-running bearing support for equipment cooling applications.

Technical Selection Reference: Confirm model, electrical rating, mounting dimensions, and airflow direction against the applicable equipment drawing before replacement.

Request a Quote
  • Overview

Overview

   Product Summary

The A2D200-AA02-01 200mm Axial Cooling Fan is designed for motor cooling, machinery ventilation, and replacement applications involving Siemens spindle and servo motor systems. Rated for 230/400V three-phase AC operation, the fan has a 70W power rating and an operating speed of 3150 RPM. Its 200mm axial fan format is intended for equipment that requires direct airflow through a motor housing, enclosure opening, or ventilation position.

In industrial equipment, motor temperature management depends on a clear airflow path as well as an appropriately selected fan. The A2D200-AA02-01 provides an axial airflow solution for moving air directly across motor surfaces and through ventilated enclosures. It can be considered when an existing fan position requires the same model reference, diameter, electrical rating, and speed. Before selecting a replacement, buyers should confirm the product label, mounting dimensions, electrical supply, airflow direction, and equipment arrangement.

img-mehj7k-94f326ab.png

Basic Description & Engineering Overview

An axial cooling an moves air in a direction generally parallel to its shaft. This direct airflow principle is commonly used in motor cooling and cabinet ventilation where air needs to enter through one opening and pass through a defined equipment space. The A2D200-AA02-01 uses a 200mm axial fan format, making it suitable for installations where the existing motor housing or machine enclosure is designed around this size.

The fan is rated for 230/400V three-phase AC operation, with 70W rated power and a speed of 3150 RPM. These confirmed electrical characteristics are important for maintenance teams and equipment builders because a replacement fan must match the available supply and the intended motor cooling arrangement. A fan that does not match the original electrical or dimensional requirements may not provide the expected installation fit or airflow direction.

The product uses pure copper motor windings and a compact motor-driven fan assembly. Copper winding material is commonly used in electric motor construction because of its electrical conductivity. The fan is also described with precision bearing support intended to help maintain smooth rotation during regular operation. Actual results depend on the complete installation environment, including airflow resistance, panel openings, guards, filters, equipment heat load, and surrounding temperature conditions.

Key Features & Technical Advantages

200mm Axial Fan Format: The fan diameter is 200mm, providing a practical size for motor housings, machinery covers, and equipment ventilation openings.

230/400V Three-Phase AC Rating: The A2D200-AA02-01 is designed for 230/400V three-phase AC electrical systems.

70W Rated Power: The confirmed 70W power rating provides a reference for equipment matching and electrical planning.

3150 RPM Operating Speed: The fan operates at 3150 RPM, supporting direct airflow for motor and enclosure cooling positions.

Pure Copper Motor Windings: The motor uses copper winding material as part of its electrical drive structure.

Precision Bearing Support: The bearing arrangement is intended to support smooth rotation and help manage vibration and operating noise.

Direct Axial Airflow: The fan moves air through a straight airflow path for intake or exhaust ventilation applications.

For industrial equipment, axial fan selection should consider more than the fan diameter. The available voltage, phase configuration, rated power, motor speed, mounting pattern, airflow direction, and surrounding enclosure structure should all be checked. A clear airflow route helps cooling air move through the target area rather than circulate around blocked or restricted sections inside the machine.

img-mrye72kx-99cedf97.png

Technical Specifications

The following table summarizes the confirmed product information. Please verify the applicable equipment drawing and product documentation before installing or replacing a fan.

Parameter Confirmed Value
Model A2D200-AA02-01
Product Type Axial Cooling Fan
Fan Diameter 200mm
Rated Voltage 230/400V AC
Electrical Supply Three-phase AC
Rated Power 70W
Rotation Speed 3150 RPM
Motor Winding Material Pure copper
Application Reference Siemens spindle and servo motor cooling replacement

Before ordering, check the model number, 200mm fan diameter, 230/400V electrical rating, three-phase supply requirement, 70W power rating, 3150 RPM speed, installation position, mounting dimensions, and airflow orientation. These checks help maintenance and engineering teams compare the fan with an existing installation or planned equipment layout.

Industry Applications

The A2D200-AA02-01 axial cooling fan can be considered for industrial equipment that requires direct ventilation around motors, drive systems, or enclosed electrical components.

  • Spindle Motor Cooling: Supports airflow around spindle motor housings in machine tools and related production equipment.
  • Servo Motor Ventilation: Can be considered for servo motor cooling positions within industrial automation and motion-control systems.
  • Machine Enclosure Ventilation: Supports direct intake or exhaust airflow in machinery housings with a compatible 200mm fan opening.
  • Motor Drive Equipment: Can be used in appropriate motor and drive cooling arrangements where the electrical rating and installation geometry match.
  • Electrical Equipment Cooling: Suitable for ventilated equipment spaces that require axial airflow through a defined opening.

Each application should be assessed according to its own cooling path. A spindle motor housing may need airflow directed across the motor body, while an equipment enclosure may need a clear route from intake opening to exhaust opening. Filters, guards, louvered panels, internal wiring, and closely spaced components can affect airflow and should be considered before installation.

Commercial Value & Selection Support

For B2B buyers, the main value of a replacement cooling fan is accurate matching. The A2D200-AA02-01 provides clear product references for model, diameter, voltage, phase configuration, power, and speed. These confirmed specifications help purchasing and engineering teams compare the fan with an existing equipment position and reduce uncertainty during maintenance planning.

Selection should be based on documented equipment requirements rather than appearance alone. A 200mm axial fan may look similar to another component but can differ in electrical supply, power rating, rotational speed, mounting arrangement, or airflow direction. Reviewing the original label and equipment drawing before replacement helps confirm whether this three-phase cooling fan is appropriate for the intended installation.

7 (1).jpg

Expert Insights: Axial Airflow for Motor Cooling

Motor cooling depends on how air moves through the equipment. Axial fans are commonly selected when air needs to travel directly through a panel, motor cover, shroud, or enclosure opening. When installed as an intake fan, the unit can direct ambient air toward heat-generating components. When installed as an exhaust fan, it can help remove warm air from an enclosed space.

System resistance should also be considered. Filters, protective guards, narrow channels, and densely arranged components can reduce the effective airflow moving through the equipment. For that reason, a replacement decision should consider the whole ventilation path, not only the fan size. Checking the equipment layout, electrical requirement, and intended airflow direction helps establish a practical installation plan.

FAQ

Q1: What is the A2D200-AA02-01 used for?
The A2D200-AA02-01 is a 200mm axial cooling fan used for spindle motor cooling, servo motor ventilation, machinery enclosure airflow, and industrial equipment heat dissipation.

Q2: What are the confirmed electrical specifications?
The fan is rated for 230/400V three-phase AC operation, with 70W rated power and a rotation speed of 3150 RPM.

Q3: Can this fan be used as a Siemens motor cooling replacement?
It is positioned for Siemens spindle and servo motor cooling replacement applications. Before replacement, confirm that the model reference, dimensions, electrical rating, mounting arrangement, and airflow direction match the existing equipment.

Q4: What should be checked before installation?
Confirm the model number, fan diameter, electrical supply, rated power, speed, mounting dimensions, equipment opening, and intended intake or exhaust airflow direction using the relevant equipment documentation.

A2D200-AA02-01 200mm 230&400V 3-Phase AC Axial Fan, 70W 3150RPM, Siemens Spindle Servo Motor Cooling Replacement

200mm Axial Cooling Fan for Motor Systems: A2D200-AA02-01 with 230/400V three-phase AC input, 70W rated power, and 3150 RPM operation.

Siemens Spindle and Servo Motor Cooling Replacement: Direct axial airflow for motor housings, machine enclosures, and industrial drive ventilation positions.

Pure Copper Motor Winding Design: Compact axial fan construction with smooth-running bearing support for equipment cooling applications.

Technical Selection Reference: Confirm model, electrical rating, mounting dimensions, and airflow direction against the applicable equipment drawing before replacement.

Request a Quote

Featured Products

400v 3 phase ac axial fan 70w 3150rpm siemens spindle servo motor cooling replacement-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000