LOBISONGDC Fan LB9238-HP 92×92×38mm

LOBISONGDC Fan LB9238-HP 92×92×38mm

The LOBISONG LB9238-HP is a 92×92×38mm brushless DC axial fan built for high static pressure cooling. Its deeper 38mm frame and optimized impeller push air through dense heatsinks, power supplies, telecom rectifiers, and control cabinets where standard 25mm fans struggle.

LOBISONG DC Fan LB9225 92×92×25mm

LOBISONG DC Fan LB9225 92×92×25mm

The LOBISONG LB9225 is a 92×92×25mm brushless DC axial fan designed for dependable thermal management in compact electronics. Its balanced impeller and precision motor deliver smooth airflow with low noise, ideal for PCs, server racks, power supplies, LED drivers, telecom cabinets, and DIY enclosures.

LOBISONG DC Fan Lb8038-HP 80×80×38mm

LOBISONG DC Fan Lb8038-HP 80×80×38mm

The LOBISONG LB8038-HP is an 80×80×38mm brushless DC fan built for applications where standard 25mm fans fall short. Its deeper housing and optimized blades deliver strong static pressure, ideal for dense heatsinks, server enclosures, telecom rectifiers, power supplies, and control cabinets.

LOBISONG DC Fan LB8025 80×80×25mm

LOBISONG DC Fan LB8025 80×80×25mm

When heat buildup threatens the performance and lifespan of your equipment, the LOBISONG LB8025 DC Axial Fan delivers the dependable cooling you need. Built in the industry-standard 80 × 80 × 25 mm frame size, this brushless DC fan combines compact dimensions with serious airflow capacity, making it an ideal thermal management solution for enclosures where space is limited but performance cannot be compromised.

Lobisong 630mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G630 Series

Lobisong 630mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G630 Series

This EC backward‑curved centrifugal fan runs on 380V power supply. Air flows axially into the center of the rotating aluminum impeller. Centrifugal force accelerates air outward along backward‑curved blades, converting rotational energy into static pressure. 

Lobisong 560mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G560 Series

Lobisong 560mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G560 Series

Easy Installation & Maintenance-Free Bearings – Optimized structural design brings simple and convenient installation process. It is fitted with maintenance-free bearings that do not require regular lubrication, cutting manual maintenance work and lowering total ownership cost for end users.

Lobisong 500mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G500‑138NT-13

Lobisong 500mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G500‑138NT-13

It can work steadily in factory workshops, purification equipment, refrigeration units and other sites with floating dust, water mist or condensate splash risks. No extra protective housing is required for most general‑industrial installation cases, simplifying equipment structural design and lowering accessory procurement cost for machine manufacturers.

Lobisong 450mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G450‑138NT-11

Lobisong 450mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G450‑138NT-11

Multi‑Protection Safe Operation – Built‑in stall protection, reverse‑polarity & over‑voltage protection and soft‑start function, the fan avoids damage caused by abnormal working conditions, reducing downtime and total cost of ownership. Multiple electronic protection mechanisms prevent motor burnout caused by blocked impeller, wrong wiring and voltage fluctuation. 

Lobisong 400mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230/380V IP55 – LBE3G400‑102NS‑14

Lobisong 400mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230/380V IP55 – LBE3G400‑102NS‑14

Specially selected motor winding and insulating materials support wide ambient temperature band.

Lobisong 355mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230/380V IP55 – LBBE3G355‑092NS‑19

Lobisong 355mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230/380V IP55 – LBBE3G355‑092NS‑19

EC Speed‑Regulating Flexibility – Equipped with 0‑10VDC / PWM dual speed control modes, the fan supports wide‑range speed adjustment from 1400RPM up to 3200RPM, the fan can be adapted to varying cooling demands, allowing system designers to balance airflow, power consumption, and noise levels according to specific operating conditions.

Lobisong 310mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230/380V IP55 – LBBE3G310‑092NS‑20

Lobisong 310mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230/380V IP55 – LBBE3G310‑092NS‑20

No extra protective housing is required for most general‑industrial installation cases, simplifying equipment structural design and lowering accessory procurement cost for machine manufacturers.

Lobisong 280mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230/380V IP55 – LBBE3G280‑092NS‑11

Lobisong 280mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230/380V IP55 – LBBE3G280‑092NS‑11

Engineered for high‑resistance ventilation scenarios, this backward‑curved impeller optimizes airflow path to cut down turbulent airflow, which effectively suppresses operating noise even under full‑load working status. Compared with forward‑curved centrifugal fans, it maintains stable air output while lowering overall system noise exposure for surrounding working staff. Both impeller materials resist oxidation and mild corrosive gas, supporting long‑term continuous operation in demanding industrial conditions.

Lobisong 270mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 115/230V IP55 – LBBE3G270‑092NU‑01

Lobisong 270mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 115/230V IP55 – LBBE3G270‑092NU‑01

EC Speed‑Regulating Flexibility – Equipped with 0‑10VDC / PWM dual speed control modes, this fan runs at fixed 1900RPM and supports flexible speed modulation to match varying cooling demands, allowing system designers to balance airflow, power consumption, and noise levels according to specific operating conditions.

Lobisong 250mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 115/230V IP55 – LBBE3G250‑072NS‑18

Lobisong 250mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 115/230V IP55 – LBBE3G250‑072NS‑18

Impeller material options include plastic, aluminum alloy and galvanized steel plate to satisfy diverse working‑condition requirements.

Lobisong 225mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G225‑072NS‑10

Lobisong 225mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G225‑072NS‑10

Backward Curved Centrifugal Design – The backward curved plastic impeller delivers high static pressure with relatively low noise, making it ideal for applications requiring airflow against system resistance.

Lobisong 220mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G220‑072NS‑11

Lobisong 220mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G220‑072NS‑11

Backward Curved Centrifugal Design – The backward curved plastic impeller delivers high static pressure with relatively low noise, making it ideal for applications requiring airflow against system resistance.

Lobisong 190mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G190‑072NS‑12

Lobisong 190mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G190‑072NS‑12

Backward Curved Centrifugal Design – The backward curved plastic impeller delivers high static pressure with relatively low noise, making it ideal for applications requiring airflow against system resistance.

Lobisong 175mm EC Backward Curved Centrifugal Fan, Outer Rotor Centrifugal Blower for Air Purification, 230‑277V IP55 – LBBE3G175‑072PS‑01

Lobisong 175mm EC Backward Curved Centrifugal Fan, Outer Rotor Centrifugal Blower for Air Purification, 230‑277V IP55 – LBBE3G175‑072PS‑01

This EC outer‑rotor backward‑curved centrifugal fan operates on 200‑277V AC power supply. Air enters axially into the centre of the PA6+GF plastic impeller. Centrifugal force accelerates air outward along backward‑curved blades, converting rotational energy into high static pressure.