LOBISONG DC Fan Lb8038-HP 80×80×38mm

The LOBISONG LB8038-HP is an 80×80×38mm brushless DC fan built for applications where standard 25mm fans fall short. Its deeper housing and optimized blades deliver strong static pressure, ideal for dense heatsinks, server enclosures, telecom rectifiers, power supplies, and control cabinets.

Request a Quote
  • Overview

Overview

Product Description (Brief Summary)

LOBISONG LB8038-HP is the 38mm-deep member of the 80mm family, a brushless DC fan drawn for pressure work rather than raw volume. Deeper housing and swept blades hold roughly 70 CFM against the resistance of dense fin stacks, so the DC fan keeps air moving where a 25mm unit stalls. Builds run on 12V, 24V or 48V with two-wire leads, tach output or PWM control, and dual ball bearings put the service life of the DC fan at 60,000 hours. Frame and impeller are PBT rated UL 94V-0, and the DC fan carries auto-restart plus polarity protection.

image.pngimage.png

Detailed Product Description & Technical Deep Dive

The catalogue entry below is copied from the LOBISONG sheet word for word. The sections that follow explain what the extra thirteen millimetres of depth buy the DC fan, and where that trade stops being worthwhile.

LOBISONG LB8038-HP 80×80×38mm DC Axial Fan — High-Pressure Cooling

The LOBISONG LB8038-HP is an 80×80×38mm brushless DC fan built for applications where standard 25mm fans fall short. Its deeper housing and optimized blades deliver strong static pressure, ideal for dense heatsinks, server enclosures, telecom rectifiers, power supplies, and control cabinets.

Available in 12V/24V/48V DC, it supports PWM speed control and tachometer output. Dual ball bearings ensure smooth operation and up to 60,000 hours of life. The PBT frame and impeller meet UL 94V-0 flame retardancy, while auto-restart and polarity protection add reliability.

Key specs: 80×80×38mm; 12/24/48V; up to ~70 CFM; high static pressure; 30–45 dBA; −20°C to +65°C; 2-wire or 3/4-wire leads. Choose LOBISONG for reliable high-pressure cooling.

Pressure, not volume, decides most fan arguments inside a cabinet. Air that enters an 80mm DC fan must cross heatsink fins, filter foam or a perforated door before it leaves, and every obstacle converts the free-air figure into a smaller working figure. A 25mm blade sits close to the motor hub and sheds flow early; the deeper housing of the LB8038-HP lets the DC fan develop a wider, more stable pressure curve, so the air continues to work its way through fin gaps of a millimetre or two. A DC fan that keeps flowing under load beats one that only looks strong on a free-air chart.

The 38mm frame still lands on the standard 80 × 80mm hole pattern, which matters to anyone replacing a tired unit in an existing panel. Leads are offered as two-wire, three-wire with tach, or four-wire with PWM, so the same DC fan can report its speed to a controller or simply spin when power arrives. Between the low-noise sleeve build and the long-life dual ball build, the DC fan covers everything from a prototype enclosure to a rectifier cabinet that runs through every holiday of the year, and the temperature window reaches from −20°C in a cold store up to the heat of a summer plant room.

Key Features & Benefits

High Static Pressure at 80mm – The deeper inlet of the DC fan lifts pressure without widening the cutout, which is exactly what dense heatsinks, foam filters and long duct runs demand of the DC fan.

70 CFM Class Airflow – Peak volume reaches about 70 CFM, so a single DC fan covers the duty that used to need two shallow units, cutting wiring, mounting work and the number of spare parts on the shelf.

PWM and Tach Options – A four-wire build lets a controller dim the speed of the DC fan to match load, while the three-wire version returns a rotation signal that tells a panel how the DC fan is behaving.

Dual Ball Bearing Builds – Where the DC fan must run continuously, preloaded ball races hold their clearance at heat, and the DC fan is rated for 60,000 hours of service before repair is due.

Flame-Retardant PBT Body – The frame and impeller of the DC fan are moulded in PBT rated UL 94V-0, which satisfies inspectors looking at a power supply, a charger or a rectifier shelf.

Protection Against Miswiring – Auto-restart clears a stalled rotor on its own, and polarity protection means one reversed lead will not destroy the electronics inside the DC fan.

Technical Specifications Table
Technical Parameter Specification Value
Product Type 80mm High-Pressure DC Axial Fan
Model Number LB8038-HP
Frame Size 80 × 80 × 38 mm
Rated Voltage 12V / 24V / 48V DC
Airflow (Max) Up to ~70 CFM
Static Pressure High static pressure build
Noise Level 30–45 dBA
Control PWM speed control, tachometer output
Lead Options 2-wire or 3/4-wire
Protection Auto-restart, polarity protection
Life Expectancy Up to 60,000 hours
Bearings Sleeve or ball bearings
Material PBT 7 fan blade
Motor life 30000 hours (sleeve) / 50000 hours (ball)
Insulation level Class A
Working temperature -20℃~60℃
Weight 177.6g
Engineering Advantages & Professional Analysis

Two fans of the same width rarely behave the same way once a panel door closes. Air that has to bend, squeeze and turn loses pressure, and an 80mm DC fan with a shallow hub simply cannot restore what the fins take away. The 38mm housing of this DC fan gives the blade room to work at a gentler angle, so the same motor watts produce usable pressure at the fin face instead of turbulence at the grill. Nothing in that change asks the buyer to re-drill, because the mounting pattern, the lead colours and the voltage options all stay where a standard 80mm DC fan left them.

Buyers ask the same question about airflow ratings, and the answer is honest: both numbers matter. Free-air CFM sells a DC fan on paper, yet the working point inside a rectifier or a servo drive sits far to the left of that figure. Test reports shipped with each batch show both the free-air point and the pressure curve, so an engineer can read where the DC fan will land once a real restriction is loaded onto it.

image.png

Target Applications

This DC fan is specified most often where airflow meets resistance:

  • Server enclosures and 1U racks: the DC fan pushes air between drive caddies that sit only a few millimetres apart.
  • Telecom rectifiers and power shelves: the DC fan keeps heatsink temperatures steady in cabinets that see direct sun.
  • Switch-mode power supplies: dense transformer and output stages stay within tolerance thanks to the DC fan.
  • Control cabinets and servo drives: the DC fan clears heat from the deepest section of the enclosure.
  • Battery chargers and test benches: the DC fan holds duty through a full shift of load cycling.

Where a 25mm fan was tried and found wanting, the LB8038-HP is the usual answer. LOBISONG keeps the DC fan in stock across all three voltages and can ship a sample unit for verification against the exact restriction the machine presents.

image.png
image.pngimage(4a1e3932f8).png

Commercial Value & B2B ROI

A deeper DC fan saves money in places that never appear on a specification sheet. One unit replaces two, so the harness, the grill and the labour of a second mounting point disappear with it. Because the pressure curve of the DC fan leaves headroom, designers stop oversizing the enclosure vents, which quietly reduces sheet-metal work. LOBISONG assembles the DC fan in house and can support OEM programmes with custom leads, private labels and kitted cartons, while sample orders are dispatched quickly enough for a design team to test the DC fan inside its own prototype.

Frequently Asked Questions (FAQ)

How is this DC fan different from the 25mm version?
Depth is the difference. The 38mm housing lets the DC fan trade some raw volume for pressure, so airflow holds up behind fins and filters that would slow a flatter unit.

Will the DC fan fit an existing 80mm cutout?
Yes. Hole spacing and screw sizes follow the standard 80mm pattern, and only the stack height changes, so a panel built for a 25mm unit accepts the DC fan without redrilling.

Which bearing type should be specified?
Choose the ball bearing build for continuous industrial duty; the sleeve version suits prototypes and light-use equipment where the DC fan runs occasionally.

image(5d87b78bf7).pngimage(dcbc0496bd).png

LOBISONG DC Fan Lb8038-HP 80×80×38mm

The LOBISONG LB8038-HP is an 80×80×38mm brushless DC fan built for applications where standard 25mm fans fall short. Its deeper housing and optimized blades deliver strong static pressure, ideal for dense heatsinks, server enclosures, telecom rectifiers, power supplies, and control cabinets.

Request a Quote

Featured Products

lobisong dc fan lb8038 hp 808038mm-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000