LBBE3G355-102NS-11 EC AC Cooling Fan

LBBE3G355-102NS-11 EC external rotor backward curved centrifugal fan, aluminum rotor, 5047m³/h at 700W for AC cooling.

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G355-102NS-11 is a 355mm medium-pressure EC backward curved centrifugal fan built for air-conditioner heat rejection, factory ventilation and high-volume heat dissipation. Driven by an external rotor EC brushless motor and fitted with an aluminum alloy impeller, this backward curved centrifugal fan delivers 5047 m³/h at 2200 r/min on 700W shaft power, producing the airflow needed to cool AC condensers, plant rooms and large ventilation boxes. The assembly carries IP55/IP54 sealing, Class F insulation, S1 continuous duty and a -25℃ to +60℃ ambient range, supplied for 400V/230V 50/60Hz. As the lead 700W model of this four-variant 355mm NS/NT family, this backward curved centrifugal fan covers standard heavy cooling duty, while the other three variants scale from 498W to 1700W, reaching 7045 m³/h for industrial exhaust and fire smoke extraction.

Model Power Speed Air Flow
LBBE3G355-102NS-11 700 W 2200 r/min 5047 m³/h
LBBE3G355-138NT-12 1700W 2700 r/min 7045 m³/h
LBBE3G355-102NS-13 585W 2050 r/min 3534 m³/h
LBBE3G355-102NS-15 498W 2150 r/min 3927 m³/h

Product Overview

Product Overview

Product Overview

Product Overview

Product Advantages

1. 355mm Large Impeller for High-Volume AC Heat Rejection

This backward curved centrifugal fan uses a 355mm aluminum alloy impeller sized to move large air volumes against the coil resistance of air-conditioning condensers and ventilation cabinets. The backward-inclined blade path converts motor rotation into medium static pressure rather than free velocity, so the unit holds 5047 m³/h through condenser coils, grille screens and short duct runs instead of losing throughput once resistance rises. The large rotor reaches rated airflow at a controlled 2200 r/min, keeping blade tip speed and vibration under control, while the aluminum wheel resists heat distortion and abrasive dust in outdoor-adjacent and plant airstreams.

2. External Rotor EC Motor with Efficient Speed Control

The drive core is an external rotor EC brushless motor, where the magnet ring rotates around the stationary stator hub. This arrangement removes belt and pulley losses, frees the motor center for impeller mounting and keeps the assembly compact at 3 kg, while delivering high torque at the low-to-moderate speeds this medium-pressure blower requires. The electronically commutated controller holds efficiency across the speed range, so this backward curved centrifugal fan can be trimmed to actual heat load instead of throttled behind a damper that wastes energy as pressure loss. Brushless operation eliminates commutator wear, and soft-start ramp-up protects upstream circuits from inrush current.

Product Overview

Product Overview

3. IP55 / IP54 Sealing for Outdoor-Adjacent and Plant Zones

The family ships in two sealing grades matched to the installation environment. IP55 resists fine dust ingress and directional splashing for dusty factory floors, condenser rooms and semi-outdoor AC positions; IP54 provides standard dust protection for protected indoor cabinet and ducted installations. The sealed housing keeps particulate away from Class F windings and ball bearings, helping this backward curved centrifugal fan hold consistent airflow over years of daily use where an open-frame motor would collect grit and drift in output over time.

4. Class F Insulation and Continuous-Duty High-Load Build

Class F winding insulation gives the windings thermal reserve for sustained high-power running, an important factor when a 700W motor sits inside a condenser plenum or closed cabinet that limits its own cooling. Rated from -25℃ to +60℃, the unit handles cold plant rooms, warm summer facilities and hot equipment bays without derating, and S1 duty confirms the backward curved centrifugal fan is engineered for non-stop continuous operation rather than intermittent short bursts. The 400V/230V 50/60Hz input covers three-phase European sites and 230V commercial grids from one model line.

5. Four Power Tiers on a Common 355mm Platform

All four models in this family share the 355mm impeller envelope and 3 kg frame, standardizing the duct collar, mounting holes and housing fitment across projects. The NS-11 backward curved centrifugal fan at 700W and 5047 m³/h leads standard AC cooling and heavy plant ventilation; the NT-12 at 1700W and 7045 m³/h serves high-volume industrial exhaust; the NS-13 at 585W and 3534 m³/h handles kitchen fume extraction; the NS-15 at 498W and 3927 m³/h covers fire smoke exhaust systems. Sealed ball bearings are relubrication-free, each unit carries CE, RoHS, ETL, BSCI, CCC and ISO certification, and the factory supports OEM/ODM customization for bulk HVAC and ventilation orders.

Product Overview

Product Overview

Application Scenarios

  • Air-Conditioner Condenser Cooling: This backward curved centrifugal fan supplies the high-volume airflow needed to reject heat from AC condensers, cooling coils and packaged air handlers in commercial buildings and industrial facilities.
  • Workshop Ventilation and Heat Dissipation: Mounted in ventilation boxes or wall outlets, the blower removes accumulated process heat and dust from production floors while supplying balanced make-up air to occupied plant areas.
  • Packaged HVAC and Exhaust Modules: System builders use the 355mm platform inside air handlers, dust collectors and cooling cabinets, relying on the common frame, two sealing options and EC drive compatibility across product lines.
  • Kitchen and Smoke Exhaust (Family Variants): The NS-13 and NS-15 models extend the platform to kitchen fume extraction and fire smoke exhaust systems, where sustained exhaust duty and high airflow are required.

Frequently Asked Questions

Q: What airflow does the NS-11 deliver? A: This backward curved centrifugal fan delivers 5047 m³/h at 2200 r/min on 700W, classified as a medium-pressure fan for AC condenser cooling, factory ventilation and high-volume heat dissipation.

Q: Is this an external rotor unit, and can speed be adjusted? A: Yes. The blower uses an external rotor EC brushless motor supporting stepless speed regulation, so airflow can be trimmed to actual cooling load, with soft-start protection and no commutator wear in service.

Q: Which variants share this 355mm platform? A: The NT-12 gives 7045 m³/h at 1700W for heavy factory exhaust; the NS-13 gives 3534 m³/h at 585W for kitchen exhaust; the NS-15 gives 3927 m³/h at 498W for smoke exhaust. All share the aluminum impeller, 3 kg frame and S1 continuous duty rating.

LBBE3G355-102NS-11 EC AC Cooling Fan

LBBE3G355-102NS-11 EC external rotor backward curved centrifugal fan, aluminum rotor, 5047m³/h at 700W for AC cooling.

Request a Quote

Featured Products

lbbe3g355 102ns 11 ec ac cooling fan-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000