LBBE3G355-102NS-11 EC external rotor backward curved centrifugal fan, aluminum rotor, 5047m³/h at 700W for AC cooling.
The LBBE3G355-102NS-11 is a 355mm medium-pressure EC backward curved centrifugal fan built for air-conditioner heat rejection, factory ventilation and high-volume heat dissipation. Driven by an external rotor EC brushless motor and fitted with an aluminum alloy impeller, this backward curved centrifugal fan delivers 5047 m³/h at 2200 r/min on 700W shaft power, producing the airflow needed to cool AC condensers, plant rooms and large ventilation boxes. The assembly carries IP55/IP54 sealing, Class F insulation, S1 continuous duty and a -25℃ to +60℃ ambient range, supplied for 400V/230V 50/60Hz. As the lead 700W model of this four-variant 355mm NS/NT family, this backward curved centrifugal fan covers standard heavy cooling duty, while the other three variants scale from 498W to 1700W, reaching 7045 m³/h for industrial exhaust and fire smoke extraction.
| Model | Power | Speed | Air Flow |
| LBBE3G355-102NS-11 | 700 W | 2200 r/min | 5047 m³/h |
| LBBE3G355-138NT-12 | 1700W | 2700 r/min | 7045 m³/h |
| LBBE3G355-102NS-13 | 585W | 2050 r/min | 3534 m³/h |
| LBBE3G355-102NS-15 | 498W | 2150 r/min | 3927 m³/h |




This backward curved centrifugal fan uses a 355mm aluminum alloy impeller sized to move large air volumes against the coil resistance of air-conditioning condensers and ventilation cabinets. The backward-inclined blade path converts motor rotation into medium static pressure rather than free velocity, so the unit holds 5047 m³/h through condenser coils, grille screens and short duct runs instead of losing throughput once resistance rises. The large rotor reaches rated airflow at a controlled 2200 r/min, keeping blade tip speed and vibration under control, while the aluminum wheel resists heat distortion and abrasive dust in outdoor-adjacent and plant airstreams.
The drive core is an external rotor EC brushless motor, where the magnet ring rotates around the stationary stator hub. This arrangement removes belt and pulley losses, frees the motor center for impeller mounting and keeps the assembly compact at 3 kg, while delivering high torque at the low-to-moderate speeds this medium-pressure blower requires. The electronically commutated controller holds efficiency across the speed range, so this backward curved centrifugal fan can be trimmed to actual heat load instead of throttled behind a damper that wastes energy as pressure loss. Brushless operation eliminates commutator wear, and soft-start ramp-up protects upstream circuits from inrush current.


The family ships in two sealing grades matched to the installation environment. IP55 resists fine dust ingress and directional splashing for dusty factory floors, condenser rooms and semi-outdoor AC positions; IP54 provides standard dust protection for protected indoor cabinet and ducted installations. The sealed housing keeps particulate away from Class F windings and ball bearings, helping this backward curved centrifugal fan hold consistent airflow over years of daily use where an open-frame motor would collect grit and drift in output over time.
Class F winding insulation gives the windings thermal reserve for sustained high-power running, an important factor when a 700W motor sits inside a condenser plenum or closed cabinet that limits its own cooling. Rated from -25℃ to +60℃, the unit handles cold plant rooms, warm summer facilities and hot equipment bays without derating, and S1 duty confirms the backward curved centrifugal fan is engineered for non-stop continuous operation rather than intermittent short bursts. The 400V/230V 50/60Hz input covers three-phase European sites and 230V commercial grids from one model line.
All four models in this family share the 355mm impeller envelope and 3 kg frame, standardizing the duct collar, mounting holes and housing fitment across projects. The NS-11 backward curved centrifugal fan at 700W and 5047 m³/h leads standard AC cooling and heavy plant ventilation; the NT-12 at 1700W and 7045 m³/h serves high-volume industrial exhaust; the NS-13 at 585W and 3534 m³/h handles kitchen fume extraction; the NS-15 at 498W and 3927 m³/h covers fire smoke exhaust systems. Sealed ball bearings are relubrication-free, each unit carries CE, RoHS, ETL, BSCI, CCC and ISO certification, and the factory supports OEM/ODM customization for bulk HVAC and ventilation orders.


Q: What airflow does the NS-11 deliver? A: This backward curved centrifugal fan delivers 5047 m³/h at 2200 r/min on 700W, classified as a medium-pressure fan for AC condenser cooling, factory ventilation and high-volume heat dissipation.
Q: Is this an external rotor unit, and can speed be adjusted? A: Yes. The blower uses an external rotor EC brushless motor supporting stepless speed regulation, so airflow can be trimmed to actual cooling load, with soft-start protection and no commutator wear in service.
Q: Which variants share this 355mm platform? A: The NT-12 gives 7045 m³/h at 1700W for heavy factory exhaust; the NS-13 gives 3534 m³/h at 585W for kitchen exhaust; the NS-15 gives 3927 m³/h at 498W for smoke exhaust. All share the aluminum impeller, 3 kg frame and S1 continuous duty rating.
LBBE3G355-102NS-11 EC external rotor backward curved centrifugal fan, aluminum rotor, 5047m³/h at 700W for AC cooling.