LBBE3G310-102NS-19 EC low-pressure backward curved centrifugal fan, 7-blade aluminum rotor, IP44, 2850m³/h at 370W, 70-80dB cooling blower.
The LBBE3G310-102NS-19 is a 310mm low-pressure EC backward curved centrifugal fan built for equipment heat dissipation and general ventilation. Its seven-blade aluminum alloy impeller is driven by a brushless EC motor rated at 370W, producing 2850 m³/h at 2300 r/min in low-pressure operation, with outlet noise registered between 70 and 80 dB. The assembly carries IP44 sealing, Class F insulation, S1 continuous duty and a -25℃ to +60℃ ambient range, supplied for 230V/400V 50/60Hz. As the middle-output model of this 310mm NS/NT family, this backward curved centrifugal fan covers standard plant and equipment cooling, while the two confirmed variants climb to 450W and 980W, reaching 4270 m³/h for heavier heat-removal duty.
| Model | Power | Speed | Air Flow |
| LBBE3G310-102NS-019 | 370W | 2300 r/min | 2850 m³/h |
| LBBE3G310-102NS-018 | 450W | 2600 r/min | 2800 m³/h |
| LBBE3G310-138NT-005 | 980W | 2600 r/min | 4270m³/h |
This backward curved centrifugal fan uses a seven-blade aluminum alloy rotor tuned for low-pressure, high-volume air movement rather than high resistance. The seven-blade spacing spreads the airflow pulse more evenly than a coarse three- or five-blade wheel, helping keep outlet noise within the 70–80 dB band and reducing discrete blade-pass hum heard near the unit. The aluminum rotor stays light on the motor shaft and resists corrosion in normal cooling airstreams, while the backward-inclined blade profile keeps output stable against light filter and grille resistance. Smooth impeller surfaces also make routine cleaning straightforward when the fan serves dusty equipment compartments.
A brushless electronically commutated motor forms the power core of this 370W unit, removing brushes and commutator wear from the maintenance schedule. The EC controller holds efficiency across the speed range, so the backward curved centrifugal fan can be trimmed to actual heat load instead of running flat out behind a throttling damper, and soft-start ramp-up protects upstream circuits from inrush current. Variable speed also lets the cooling airflow rise and fall with equipment temperature, avoiding over-cooling and the extra noise and energy that fixed-speed fans waste during idle periods.




Rated IP44, this cooling centrifugal blower keeps solid foreign objects over 1mm out and resists splashing water from any direction, a sensible protection level for equipment cabinets, ventilation boxes and protected indoor plant rooms. The sealed housing keeps dust away from Class F windings and ball bearings, helping this backward curved centrifugal fan hold consistent airflow over years of daily use where an open-frame motor would accumulate grit and lose output. The IP44 enclosure keeps the unit cost-effective for standard cooling zones that do not require full dust-tight or washdown protection.
Class F winding insulation gives the windings reserve heat capacity for sustained full-load running, an important factor when the blower sits inside a closed equipment compartment that limits motor self-cooling. Rated from -25℃ to +60℃, the unit handles cool plant rooms, warm workshops and seasonal temperature swings without derating, and S1 duty confirms the backward curved centrifugal fan is engineered for non-stop continuous operation rather than short intermittent bursts. The 230V/400V dual-voltage 50/60Hz input covers commercial single-phase and three-phase site supplies from one model line.
Three performance models share the same 310mm aluminum impeller platform, so the duct collar and mounting interface can be standardized across cooling projects. The NS-19 backward curved centrifugal fan at 370W and 2850 m³/h covers standard equipment and workshop cooling; the NS-18 at 450W and 2800 m³/h handles comparable medium-duty heat removal; the NT-05 at 980W and 4270 m³/h serves heavier high-volume cooling. Sealed ball bearings are relubrication-free, each unit carries ISO, BSCI, ETL, CE, CCC, RoHS and GS certification, and the factory supports OEM/ODM customization for bulk ventilation orders.




Q: What airflow does the NS-19 deliver? A: This backward curved centrifugal fan delivers 2850 m³/h at 2300 r/min on 370W, classified as a low-pressure fan for standard equipment cooling and general ventilation.
Q: How noisy is the unit? A: The rated noise range is 70–80 dB. The seven-blade aluminum rotor smooths the airflow pulse, and speed trimming, ducting or enclosure separation can further reduce noise reaching occupied zones.
Q: Which variants share this 310mm platform? A: The NS-18 gives 2800 m³/h at 450W, and the NT-05 gives 4270 m³/h at 980W. The NT-25 listed in the model group has no performance row in the supplied table; confirm its power, speed and airflow from the variant datasheet before ordering.
LBBE3G310-102NS-19 EC low-pressure backward curved centrifugal fan, 7-blade aluminum rotor, IP44, 2850m³/h at 370W, 70-80dB cooling blower.