EC High-efficiency Fan

In an era dominated by strict carbon-emission mandates and soaring electricity costs, legacy cooling systems are draining your corporate profits. Our cutting-edge EC High-efficiency Fan series combines the simplicity of AC power with the smart control and extreme energy savings of brushless DC technology, revolutionizing your facility's energy profile overnight.   Representing the pinnacle of green thermal engineering, our EC High-efficiency Fan solutions cut energy consumption by up to 50% while offering intelligent modbus communication and unmatched system reliability for modern eco-conscious industries.   Up to 50% Energy Savings with Brushless EC Motors: Our EC High-efficiency Fan line features integrated smart electronics that convert AC input to DC internally, driving a permanent-magnet brushless motor. This state-of-the-art design eliminates rotor copper losses, allowing the EC High-efficiency Fan to run significantly cooler and use half the electricity of a conventional AC fan. Seamless Modbus Communication & Remote Monitoring: Welcome to the era of smart factory automation. Every EC High-efficiency Fan can be integrated directly into your building management system (BMS) or industrial control network via Modbus RTU. This allows your operators to remotely monitor fan speeds, power usage, and diagnostic codes in real-time, enabling proactive predictive maintenance. Custom Engineering for Unique Project Parameters: We understand that advanced green building projects and high-tech cleanrooms require precise, non-standard specifications. Our technical team specializes in Custom Engineering, adapting the physical dimensions, mounting brackets, and control algorithms of the EC High-efficiency Fan to align perfectly with your unique system requirements. Unmatched Supply Reliability & Guaranteed Lead Times: Large-scale commercial construction and green energy projects operate on incredibly strict timelines. We guarantee a 98% on-time delivery rate for our EC High-efficiency Fan products, backed by reliable lead times and prompt shipping, ensuring your projects are completed on schedule and within budget.     Step into the future of sustainable industrial cooling—partner with our engineering experts to integrate the EC High-efficiency Fan into your systems and instantly slash your operational carbon footprint!     The Green Revolution in HVAC and Data Center Cooling The demand for high-efficiency ventilation has transitioned from a luxury to an absolute regulatory necessity. Data centers, hospital ventilation systems, and modern cleanrooms operate thousands of filtration units simultaneously, where even a 1% increase in motor efficiency translates to millions of dollars saved annually. The EC High-efficiency Fan is specifically designed to meet these stringent environmental standards.   By integrating a micro-controller directly within the motor housing, the EC High-efficiency Fan continuously monitors its own operating conditions and adjusts its load profile to maintain optimal aerodynamic efficiency across its entire speed range.   This internal conversion means that unlike traditional AC fans that suffer from massive efficiency drops when running at lower speeds, our EC High-efficiency Fan retains its ultra-high efficiency even when dialed down to just 10% of its maximum capacity. This makes it the ideal candidate for variable air volume (VAV) systems and advanced climate-control applications.   Precision Customization & Advanced Control Protocols To maximize the value of the EC High-efficiency Fan in highly complex HVAC systems, integration flexibility is critical. Our engineering team has developed a versatile control interface that supports multiple input signals, including 0-10V analog voltage, 4-20mA current loops, and pulse-width modulation (PWM). This compatibility ensures that whether you are upgrading a legacy facility or designing a brand-new, state-of-the-art intelligent building, the EC High-efficiency Fan can be wired directly into your existing infrastructure without requiring expensive external controller interfaces.   Our Custom Engineering department is fully equipped to program custom speed curves, soft-start times, and specific alarm parameters directly into the fan’s internal microprocessor during the manufacturing process, delivering a truly plug-and-play solution tailored to your exact operational requirements.   Global Partnerships & Complete Lifecycle Assurance Investing in high-efficiency technology requires a trustworthy partner who is committed to long-term operational success. Over several decades, our automated manufacturing factory has established deep, long-term cooperation with elite partners in Europe, Russia, India, and the Americas. We secure these relationships not only through superior hardware but also through comprehensive lifecycle services.   When you purchase our EC High-efficiency Fan systems, you gain immediate access to our 24/7 technical support network. Our engineers are always available to assist with remote commissioning, electrical integration troubleshooting, and software configuration. Furthermore, we provide our global customers with a steady stream of Genuine Spare Parts and highly structured Maintenance & Technical Training. This end-to-end service framework ensures that your transition to high-efficiency EC technology is smooth, highly profitable, and completely risk-free.     Integrated Microelectronics and Active Power Factor Correction At the core of the EC High-efficiency Fan is an onboard intelligent electronic control board. This specialized control module converts incoming AC power (whether 115V or 230V) to DC voltage via a highly efficient bridge rectifier. The microelectronics integrated into our EC High-efficiency Fan feature Active Power Factor Correction (PFC) circuitry. This advanced design ensures that the power factor remains extremely high (typically >0.95) under all operating speeds. By minimizing reactive power, the EC High-efficiency Fan significantly reduces the load placed on your facility’s electrical transformers and distribution wiring. This low-loss operation prevents harmonic feedback from entering your power grid, protecting sensitive nearby laboratory instruments, hospital telemetry, or telecommunications servers from electromagnetic disruptions.   Advanced Closed-Loop Speed Regulation and Diagnostic Safety Unlike legacy ventilation fans that rely on imprecise open-loop controls, our EC High-efficiency Fan provides precise, closed-loop speed regulation. The integrated microprocessor constantly monitors the rotor’s magnetic position and actual rotational frequency. If external wind resistance increases—due to a clogging air filter in a cleanroom, for instance—the EC High-efficiency Fan automatically increases its torque output to maintain a constant, pre-programmed volumetric airflow rate. This smart capability ensures a sterile, stable environment in critical applications. Furthermore, the EC High-efficiency Fan is equipped with real-time digital diagnostics. Through the Modbus RTU interface, the fan can transmit failure codes, over-current warnings, or bearing temperature alarms to your central control panel, allowing maintenance teams to schedule targeted servicing before an actual shutdown occurs.    Strategic Procurement Optimization for Eco-conscious Projects Adopting green technology must make commercial sense. For large-scale data centers, HVAC installations, and green architectural projects, our EC High-efficiency Fan models offer the fastest return on investment (ROI) in the industry. By transitioning to our EC High-efficiency Fan lineup, energy managers typically see a full payback on capital equipment costs within 12 to 18 months through reduced utility bills alone. To assist our overseas partners, we offer comprehensive tier-based pricing structures that make high-efficiency upgrades highly affordable for large project pipelines. Coupled with our guaranteed 98% on-time shipping and comprehensive training programs, we provide your engineering and procurement teams with a seamless, highly profitable transition to sustainable thermal-management technology.
LBBE3G190-072NS-06 EC Backward Curved Fan

LBBE3G190-072NS-06 EC Backward Curved Fan

190mm high-output EC backward curved centrifugal fan with PA66 impeller, IP55 rated, delivers 973m³/h for factory heat dissipation and commercial ventilation.

LBBE3G175-072PS-04 EC Heat Dissipation Fan

LBBE3G175-072PS-04 EC Heat Dissipation Fan

175mm high-speed EC backward curved centrifugal fan with PA66 impeller, IP54/IP55, delivers 912m³/h for kitchen exhaust and industrial heat dissipation.

LBBE3G175-072PS-01 EC Exhaust Centrifugal Fan

LBBE3G175-072PS-01 EC Exhaust Centrifugal Fan

LBBE3G175-072PS-01 compact EC backward curved centrifugal fan with PA66 impeller, IP55 grease-resistant seal, built for kitchen exhaust and EFU ventilation.

LBBE3G190-072NS-14 EC Backward Curved Fan

LBBE3G190-072NS-14 EC Backward Curved Fan

LBBE3G190-072NS-14 low-power EC backward curved centrifugal fan with PA66 impeller, IP55/IP54 optional, built for energy-saving workshop and factory ventilation.

LBBE3G190-072NS-06 EC Backward Curved Centrifugal Fan

LBBE3G190-072NS-06 EC Backward Curved Centrifugal Fan

190mm EC backward curved centrifugal fan with PA66 impeller, IP55 rated, delivers 973m³/h airflow for factory heat dissipation and commercial air purification systems.

Lobisong 175mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G175-072PS-01

Lobisong 175mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G175-072PS-01

Technical Description

Impeller Material | PA66 Engineering Plastic
Bearing Type| Ball Bearing
Duty Type| S1 Continuous Operation
Protection Class | IP55
Insulation Class | F
Operating Temperature | -25℃ ~ +60℃
Power Supply | 230V, 50/60Hz
Model| LBBE3G175-072PS-01
Impeller Diameter | 175mm
Shaft Power | 55W
Matched Motor Power | 55W
Speed | 2800 r/min
Air Flow(Max) | 536 m³/h

ec high efficiency fan_3-1

Key Features & Benefits

Backward Curved Centrifugal Design – PA66 Impeller – The backward curved impeller is constructed from high-strength PA66 engineering plastic. It delivers high static pressure with relatively low noise, perfectly suitable for kitchen exhaust scenarios where the fan needs to push airflow against grease filter and duct system resistance. PA66 material features excellent heat resistance, anti-grease and anti-aging performance. The lightweight impeller enables smooth, long-duration continuous running. Optimized backward curved blade profile reduces airflow turbulence and energy consumption, generating stable high-pressure airflow to efficiently discharge oily kitchen fume.

Multiple Performance Variants for Kitchen & Factory Ventilation – This 175mm EC centrifugal fan series provides three optional performance versions to satisfy different ventilation design requirements. The LBBE3G175-072PS-01 variant has 55W rated shaft power, operating at 2800 r/min with maximum airflow of 536 m³/h. Other available models: LBBE3G175-072PS-02 (85W /3300rpm, 742m³/h for factory ventilation) and LBBE3G175-072PS-03 (115W /4400rpm, 700m³/h for kitchen exhaust). System designers can select the proper model to balance airflow output, power draw and noise level for kitchen fume extraction and industrial ventilation projects.

IP55 Protection Grade – Rated IP55 protection against dust ingress and water splash. It shields the built-in EC motor and electronic drive components from oil mist, fine dust and splashing water. The sealed structure guarantees stable operation in greasy kitchen environments, making it ideal for range hood and kitchen ventilation equipment that continuously handles oil-laden air.

Class F Insulation & Wide Operating Temperature – Adopts Class F motor insulation to withstand temperature rise under continuous working load. The fan can reliably operate within ambient temperature range of -25℃ ~ +60℃, adapting to temperature fluctuation in kitchen and factory spaces. S1 continuous operation mode supports non-stop long-hour running for exhaust and ventilation systems.

Ball Bearing, Maintenance-Free Operation – Equipped with precision ball bearings for smooth rotation, low vibration and low friction loss. No regular lubrication or routine maintenance required, cutting downtime and lowering total cost of ownership over the product lifespan. Compact structure allows simple installation inside kitchen hood cabinets and easy integration into ventilation systems.

Lobisong 175mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54/IP55 – LBBE3G175-072NS-08

Lobisong 175mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54/IP55 – LBBE3G175-072NS-08

LBBE3G175 EC backward curved centrifugal fan with PA66 impeller features IP54/IP55 protection and Class F insulation for air purification & ventilation.

Lobisong 155mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP44 – LBBE3G155-072NS-02

Lobisong 155mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP44 – LBBE3G155-072NS-02

Tailored Performance for Factory Heat Dissipation – This 155mm EC centrifugal fan variant LBBE3G155-072NS-02 features 40W rated shaft power, running at 3750 r/min with maximum airflow up to 433 m³/h. It is specially designed for factory workshop heat dissipation and ventilation.

Lobisong 175mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G175-072NS-03

Lobisong 175mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55 – LBBE3G175-072NS-03

Multiple Performance Options for Factory Ventilation– This 175mm EC centrifugal fan series provides three different performance variants to meet diverse factory ventilation demands. The LBBE3G175-072NS-03 variant comes with 85W rated shaft power, operating at 3300 r/min with maximum airflow of 742 m³/h.
Lobisong 133mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54/IP55 – LBBE3G133-072PS-02

Lobisong 133mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54/IP55 – LBBE3G133-072PS-02

The LBBE3G133-072PS-02 is a compact, energy-efficient EC backward curved centrifugal fan purpose-built for commercial kitchen fume extraction and light industrial smoke exhaust.

LBBE3G133-072NS-06 Backward Curved EC Centrifugal Fan

LBBE3G133-072NS-06 Backward Curved EC Centrifugal Fan

The LBBE3G133-072NS-06 is a compact high-performance backward curved EC centrifugal fan purpose-built for factory ventilation and industrial heat dissipation. 

Lobisong 630mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 400V IP54 – LBBE3G630-188NT Series

Lobisong 630mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 400V IP54 – LBBE3G630-188NT Series

High Power Performance & Multiple Model Options – This 630mm EC centrifugal fan series comes with 3 optional models with different power and speed specifications. The LBBE3G630-188NT-06 runs at 1300 r/min with shaft power of 2975W and airflow up to 19247 m³/h; LBBE3G630-188NT-07 reaches 1380 r/min, 3850W shaft power with airflow of 21100 m³/h; LBBE3G630-188NT-09 operates at 1760 r/min, shaft power 5570W and max airflow 21742 m³/h.

Lobisong 500mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, EC – LBBE3G500 Series

Lobisong 500mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, EC – LBBE3G500 Series

EC Energy-Saving Motor – Equipped with high-efficiency EC brushless motor, this 500mm centrifugal blower provides wide speed adjustable range, greatly reduces power consumption compared with traditional AC fans. It maintains stable performance under continuous long-time operation, bringing remarkable energy saving benefits for end users. Multiple model options are available with different power ratings from 870W up to 4270W, supporting various airflow demands up to 14214 m³/h.

LBBE(RT)320-PT-02 EC Backward Curved Centrifugal Fan for Rail Transit

LBBE(RT)320-PT-02 EC Backward Curved Centrifugal Fan for Rail Transit

Optimized for subway auxiliary inverter heat dissipation, this industrial centrifugal blower features DC stepless speed regulation, dual IP55/IP44 protection ratings, Class F insulation and rugged all-metal construction.

LBBE(RT)320-PT-01 EC Backward Curved Centrifugal Fan for Rail Transit

LBBE(RT)320-PT-01 EC Backward Curved Centrifugal Fan for Rail Transit

Industrial Backward Curved Centrifugal Fans | Rail Transit EC Cooling Blowers

Lobisong 630mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G630 Series

Lobisong 630mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G630 Series

This EC backward‑curved centrifugal fan runs on 380V power supply. Air flows axially into the center of the rotating aluminum impeller. Centrifugal force accelerates air outward along backward‑curved blades, converting rotational energy into static pressure. 

Lobisong 560mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G560 Series

Lobisong 560mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G560 Series

Easy Installation & Maintenance-Free Bearings – Optimized structural design brings simple and convenient installation process. It is fitted with maintenance-free bearings that do not require regular lubrication, cutting manual maintenance work and lowering total ownership cost for end users.

Lobisong 500mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G500‑138NT-13

Lobisong 500mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP55 – LBBE3G500‑138NT-13

It can work steadily in factory workshops, purification equipment, refrigeration units and other sites with floating dust, water mist or condensate splash risks. No extra protective housing is required for most general‑industrial installation cases, simplifying equipment structural design and lowering accessory procurement cost for machine manufacturers.