LOBISONG DC Fan LB20060 200×200×60mm

The LOBISONG LB20060 is a 200×200×60mm brushless DC axial fan engineered for maximum airflow in large enclosures. Its oversized impeller and deep 60mm frame move massive air volume through heatsinks, filters, and ducted systems, ideal for telecom cabinets, servers, power supplies, inverters, HVAC equipment, and industrial control panels.

Request a Quote
  • Overview

Overview

Product Description (Brief Summary)

LOBISONG LB20060 is a 200 × 200 × 60mm brushless DC fan engineered for maximum airflow in large enclosures. The oversized impeller drives 300 to 600 CFM through heatsinks, filters and ducted systems at speeds from 1,200 to 2,800 RPM, with pressure reaching 0.55 in H₂O. The DC fan is offered in 12V, 24V and 48V versions with tach or PWM control, carries ball bearings rated for 50,000 hours and a PBT body in UL 94V-0 material, and the whole DC fan weighs 2.4kg.

image.pngimage.png

Detailed Product Description & Technical Deep Dive

The LB20060 description from the LOBISONG sheet is reproduced below without change. The text that follows covers what a 200mm DC fan does for HVAC equipment, electrical rooms and large cabinets.

LOBISONG LB20060 200×200×60mm DC Fan — Maximum Airflow Cooling

The LOBISONG LB20060 is a 200×200×60mm brushless DC axial fan engineered for maximum airflow in large enclosures. Its oversized impeller and deep 60mm frame move massive air volume through heatsinks, filters, and ducted systems, ideal for telecom cabinets, servers, power supplies, inverters, HVAC equipment, and industrial control panels.

Available in 12V, 24V, and 48V DC, it supports 2-wire, 3-wire tach, and 4-wire PWM. Dual ball bearings ensure stable operation and up to 60,000 hours of life. The PBT frame and impeller meet UL 94V-0 flame retardancy, with auto-restart and polarity protection.

Key specs: 200×200×60mm; 12/24/48V; speed ~1,200–2,800 RPM; airflow ~300–600 CFM; static pressure up to ~0.55 in H₂O; noise 45–65 dBA; temp −20°C to +65°C. Choose LOBISONG LB20060 for powerful, dependable cooling.

When a cabinet reaches the size of a switchboard or an air-handling compartment, cooling stops being a matter of a small fan and becomes a question of air exchange rate. A 200mm DC fan moves six hundred cubic feet each minute at its top speed, which is enough to renew the air inside a substantial enclosure several times over during the hottest hour of the day. Because the DC fan turns slowly for that output, the noise it makes lands in the lower part of the spectrum, and the wear on its bearings arrives later than it would on a smaller unit working at double the speed.

Electrical rooms and HVAC compartments rarely hold a single heat source. Inverters, drives, transformers and control gear each warm the air around them, and the DC fan has to keep the room from stratifying so that the upper shelves do not sit in a pool of hot air. Mounted high on a wall or on a cabinet door, the DC fan draws warm air out and pulls cooler air through low vents, which is why plant engineers reach for this size when a room has outgrown its original ventilation. Voltage options and PWM wiring make the DC fan easy to integrate, and the DC fan keeps that exchange running day and night.

Key Features & Benefits

Up to 600 CFM – The DC fan shifts the volume a large enclosure or a small plant room needs, replacing several smaller units with one mounting point.

0.55 in H₂O Pressure – Even with filters and fin stacks in the path, the DC fan keeps a working point that suits real installations.

Slow-Turning Oversized Impeller – A wide rotor lets the DC fan reach its duty at moderate speed, which lowers both wear and the pitch of the noise the DC fan makes.

50,000 Hour Ball Bearings – Continuous industrial duty is the design case for this DC fan, and its races are sized accordingly.

Flexible Installation – Wall, door or roof mounting works, and the DC fan can be wired simply or driven through a PWM signal from a building controller.

PBT UL 94V-0 Frame – The DC fan is built from flame-retardant material that passes the inspection requirements of power and control equipment.

Technical Specifications Table
Technical Parameter Specification Value
Product Type 200mm High-Volume DC Axial Fan
Model Number LB20100%60
Frame Size 200 × 200 × 60 mm
Rated Voltage 12V / 24V / 48V DC
Speed Range 1,200–2,800 RPM
Airflow 300–600 CFM
Static Pressure 0.55 in H₂O max.
Noise Level 45–65 dBA
Lead Options 2-wire, 3-wire tach, 4-wire PWM
Life Expectancy Up to 50,000 hours
Bearings Ball bearings
Material PBT 5 fan blade
Motor life 50000 hours
Insulation level Class A
Working temperature -20℃~60℃
Weight 2400g
Engineering Advantages & Professional Analysis

Air exchange is the number that matters in a large space. A 200mm DC fan rated at six hundred cubic feet per minute will cycle the volume of a modest cabinet in seconds, and in a plant room it will usually be paired with an opposing vent so fresh air enters low and hot air leaves high. Because the DC fan delivers that flow at a modest rotational speed, the acoustic signature stays within the limits expected in workshops, and the airflow is broad enough to avoid dead zones behind the equipment.

Durability follows the same logic. Large bearings supporting a moderate speed accumulate less stress than small bearings turning quickly, and the DC fan is rated for fifty thousand hours of that duty. The impeller is balanced after moulding so the DC fan does not set up vibration in a sheet-metal door, and the frame is stiffened to maintain tip clearance when the mounting surface is less than perfectly flat.

image.png

Target Applications

Where a large DC fan simplifies the design:

  • HVAC compartments and air handling sections: the DC fan drives air through filters and coils.
  • Switch rooms and electrical enclosures: the DC fan pulls hot air from the top of the room.
  • Telecom and data cabinets: the DC fan clears the exhaust side of tall racks.
  • Industrial power supplies and rectifiers: the DC fan keeps heavy fin stacks inside their thermal margin.
  • Greenhouse and livestock buildings: the DC fan supports ventilation where mains power is inconvenient.

Large spaces need air exchange rather than spot cooling, and this DC fan delivers it in a package that sips power. LOBISONG supplies the DC fan across three voltages and can provide samples for plant engineers who want to measure the DC fan against a real room.

image.pngimage(4a1e3932f8).png

Commercial Value & B2B ROI

Project buyers look at the DC fan as a line item that decides several others. One large unit replaces a row of smaller fans, which removes wiring, grills and mounting brackets from the bill of materials, and the DC fan saves the labour that would have been spent on each of them. Energy metering usually shows a further saving, since a slow impeller draws less than the equivalent airflow from high-speed units. LOBISONG manufactures the DC fan in house and supports tender work with drawings, performance curves and delivery schedules tied to the construction programme.

Frequently Asked Questions (FAQ)

Is the DC fan powerful enough to ventilate a small room?
It is, when paired with a low-level inlet. The DC fan removes air from the highest point of the room, which is where heat collects.

How is a 48V version normally supplied?
From a rectifier or a DC bus, though many sites also use a mains-to-48V supply dedicated to the DC fan, so the DC fan needs no inverter. LOBISONG can advise on the wiring.

Does the DC fan ship with a grill?
The unit is supplied as a fan, and finger guards or filters can be quoted with it. Fit a guard whenever the DC fan is within reach of staff.

image(5d87b78bf7).pngimage(dcbc0496bd).png

LOBISONG DC Fan LB20060 200×200×60mm

The LOBISONG LB20060 is a 200×200×60mm brushless DC axial fan engineered for maximum airflow in large enclosures. Its oversized impeller and deep 60mm frame move massive air volume through heatsinks, filters, and ducted systems, ideal for telecom cabinets, servers, power supplies, inverters, HVAC equipment, and industrial control panels.

Request a Quote

Featured Products

lobisong dc fan lb20060 20020060mm-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000