LOBISONG DC Fan LB17250D 172×150×51mm

The LOBISONG LB17250D is a 172×150×51mm brushless DC axial fan built for powerful, high-volume airflow. Its large impeller and deep 51mm frame move air through dense heatsinks and filters, ideal for servers, telecom, power supplies, and industrial panels.

Request a Quote
  • Overview

Overview

Product Description (Brief Summary)

LOBISONG LB17250D is a 172 × 150 × 51mm brushless DC fan built for equipment that works outdoors or in cold stores. Seven blades and a deep frame lift 180 to 350 CFM against a pressure ceiling near 0.50 in H₂O, and the DC fan keeps that output from 1,500 to 3,500 RPM. Its working window stretches from −30℃ to 70℃, and the bearing set carries a 70,000-hour rating, so the DC fan suits machinery that must not be visited every season. Builds cover 12V, 24V and 48V with tach or PWM wiring.

image.png

image.png

Detailed Product Description & Technical Deep Dive

The LOBISONG sheet entry for the LB17250D is repeated below without alteration. The notes that follow deal with the two features that separate this DC fan from its standard sibling: a wider temperature band and a longer rated life.

LOBISONG LB17250D 172×150×51mm DC Fan — High-Volume Cooling

The LOBISONG LB17250D is a 172×150×51mm brushless DC axial fan built for powerful, high-volume airflow. Its large impeller and deep 51mm frame move air through dense heatsinks and filters, ideal for servers, telecom, power supplies, and industrial panels.

Available in 12V, 24V, and 48V DC, it supports 2-wire, 3-wire tach, and 4-wire PWM. Dual ball bearings ensure stable operation and up to 60,000 hours of life. The PBT frame and impeller meet UL 94V-0 flame retardancy, with auto-restart and polarity protection.

Key specs: 172×150×51mm; 12/24/48V; speed ~1,500–3,500 RPM; airflow ~180–350 CFM; static pressure up to ~0.50 in H₂O; noise 40–58 dBA; temp −20°C to +65°C. Choose LOBISONG LB17250D for dependable high-volume cooling solutions.

Cold is harder on a fan than heat in one respect: lubricant thickens, and a DC fan that was free-turning in a workshop can labour during the first minutes of a winter morning. The LB17250D answers with a bearing arrangement and grease selected for deep sub-zero starts, so the DC fan comes up to speed at −30℃ instead of groaning until the cabinet warms. The seven-blade impeller adds pressure at low speed as well, which is useful when a DC fan has to shift frost-heavy air inside a cold room or a refrigerated dock.

Longevity follows from the same design choices. Fewer starts, gentler speed, and races rated for 70,000 hours mean the DC fan can serve a remote pumping station, an outdoor telecom hut or a cold-chain warehouse across several maintenance cycles without a swap. The speed of the DC fan can be managed through a PWM lead, and the tach output tells a monitoring system that the DC fan is turning, which matters when the site is visited twice a year rather than twice a week.

Key Features & Benefits

−30℃ to 70℃ Working Band – Wide temperature coverage lets the DC fan start in a freezer aisle and keep running on a sunlit roof without a change of specification.

70,000 Hour Bearing Rating – The longest life figure in the range belongs to this DC fan, which is built for sites where a service visit costs more than the part.

Seven-Blade Impeller – Extra blades raise pressure at low speed, so the DC fan moves air that has grown dense with cold or heavy with dust.

180–350 CFM Coverage – Volume stays useful across the whole speed window, letting the DC fan hold a rectifier or inverter cabinet steady through the seasons.

Three Voltage Builds – 12V, 24V and 48V versions keep the DC fan compatible with vehicle, telecom and industrial supply practice.

Protected Electronics – Auto-restart and polarity protection are standard, so a jammed rotor or a reversed lead will not end the life of the DC fan.

Technical Specifications Table
Technical Parameter Specification Value
Product Type 172mm E100%tended-Life DC Axial Fan
Model Number LB17250D
Frame Size 172 × 150 × 51 mm
Rated Voltage 12V / 24V / 48V DC
Speed Range 1,500–3,500 RPM
Airflow 180–350 CFM
Static Pressure 0.50 in H₂O max.
Noise Level 40–58 dBA
Lead Options 2-wire, 3-wire tach, 4-wire PWM
Life Expectancy Up to 70,000 hours
Bearings Ball bearings
Material PBT 7 fan blade
Motor life 70000 hours
Insulation level Class A
Working temperature -30℃~70℃
Weight 820g
Engineering Advantages & Professional Analysis

Machines that live outside are judged by their worst day, not their average one. A cold snap, a heat wave and a dusty harvest all happen inside the same year, and the DC fan has to keep working through each of them. The wider band of the LB17250D was set by testing the DC fan at both ends of its range rather than by extrapolating a mild-climate figure, and the seven-blade rotor was chosen because cold air is dense and dense air needs pressure. Inside a roadside cabinet or a chiller vestibule, the DC fan simply has fewer excuses to fail.

Service economics close the argument. When a technician has to drive two hours to reach a remote site, the labour dwarfs the price of the part, so the sensible choice is a DC fan with margin on every specification. Rated life, temperature range and pressure head all carry headroom in the LB17250D, and the DC fan is delivered with documentation that satisfies an audit trail; on a critical installation, that paperwork counts as much as the DC fan itself.

image.png

Target Applications

Where an extended-range DC fan earns its keep:

  • Cold stores and refrigerated docks: the DC fan starts reliably at deep sub-zero temperatures.
  • Outdoor telecom cabinets: the DC fan clears heat in huts that see sun, rain and winter frost.
  • Renewable energy cabins: the DC fan cools inverters and battery equipment on remote sites.
  • Agricultural and irrigation control: the DC fan operates in sheds where dust and temperature swings are routine.
  • Rail and marine equipment rooms: the DC fan holds duty through long unattended shifts.

Remote sites reward the DC fan that needs the fewest visits. LOBISONG supplies the LB17250D in all three voltages, and can provide test data or a sample unit so the DC fan can be proven against the temperature profile the installation will actually face.

image.pngimage(4a1e3932f8).png

Commercial Value & B2B ROI

Total cost of ownership is the lens this DC fan was designed through. A longer rated life lowers the spares count a site must hold, and a wider temperature band removes the need to stock two different units for summer and winter roles. Because the DC fan shares the 172 × 150mm pattern with its standard sibling, an operator can upgrade a critical cabinet without new metalwork. LOBISONG assembles the DC fan in its own factory and can supply OEM batches with custom speeds, harnesses and labels, so the DC fan matches the equipment it protects rather than the other way round.

Frequently Asked Questions (FAQ)

Will the DC fan start after a night at −30℃?
Yes. The bearing grease and clearances of the DC fan were selected for cold starts, and the drive electronics deliver enough torque to break the rotor free.

How does the DC fan compare with the standard version?
Same footprint, longer life and a wider temperature window. Where the duty is remote or punishing, the DC fan in this build is the safer of the two.

Can the site monitor the DC fan remotely?
A tach output reports rotation to a controller, and a PWM input allows the speed of the DC fan to be set remotely as conditions change.

image(5d87b78bf7).pngimage(dcbc0496bd).png

LOBISONG DC Fan LB17250D 172×150×51mm