LOBISONG DC Fan LB12038-HP 120×120×38mm

The LOBISONG LB12038-HP is a 120×120×38mm brushless DC axial fan built for high-static-pressure cooling. Its deeper 38mm frame and optimized impeller push air through dense heatsinks, filters, and ducts, ideal for servers, telecom rectifiers, power supplies, inverters, and industrial cabinets.

Request a Quote
  • Overview

Overview

Product Description (Brief Summary)

LOBISONG LB12038-HP is a 120 × 120 × 38mm brushless DC fan built for high static pressure. Its deeper frame and nine-blade impeller drive air through dense heatsinks, filters and duct runs, delivering 90 to 150 CFM with a pressure ceiling near 0.45 in H₂O. The DC fan runs on 12V, 24V or 48V and accepts two-wire, tach or PWM connections. Dual ball bearings place the life of the DC fan at 60,000 hours, while the PBT body of the DC fan carries a UL 94V-0 rating and protective electronics.

image.pngimg-mv1rp7ia-27ef08ad.png

Detailed Product Description & Technical Deep Dive

The LB12038-HP paragraph from the LOBISONG sheet is reproduced below without alteration. The notes that follow deal with filters, ducts and the reason a pressure-first DC fan pays for itself in dirty plants.

LOBISONG LB12038-HP 120×120×38mm DC Fan — High-Pressure Cooling

The LOBISONG LB12038-HP is a 120×120×38mm brushless DC axial fan built for high-static-pressure cooling. Its deeper 38mm frame and optimized impeller push air through dense heatsinks, filters, and ducts, ideal for servers, telecom rectifiers, power supplies, inverters, and industrial cabinets.

Available in 12V, 24V, and 48V DC, it supports 2-wire, 3-wire tach, and 4-wire PWM. Dual ball bearings ensure stable operation and up to 60,000 hours of life. The PBT frame and impeller meet UL 94V-0 flame retardancy, with auto-restart and polarity protection.

Key specs: 120×120×38mm; 12/24/48V; speed ~1,500–3,000 RPM; airflow ~90–150 CFM; static pressure up to ~0.45 in H₂O; noise 35–48 dBA; temp −20°C to +65°C. Choose LOBISONG LB12038-HP for powerful, dependable cooling.

Air that crosses a filter loses energy before it ever reaches the equipment, and a duct run adds more loss with every bend. A DC fan chosen on free-air volume alone will be undersized the moment media loads with dust, which is why this model leans on pressure. Nine blades and a 38mm housing let the DC fan build a curve that stays useful even when the inlet is half blinded, and the motor current is specified with enough headroom that the DC fan does not trail off as the working point moves left. In a workshop that sees cardboard dust or fabric lint, that margin is what keeps the electronics alive.

Ducted equipment asks the same question from a different angle. When a DC fan pushes air down a flexible duct to a remote cabinet section, every metre of hose costs pressure, and a shallow unit will simply recirculate. The deeper impeller of this DC fan holds the flow, and the PWM option lets a controller slow the DC fan when the duct damper closes, so the machine is not fighting its own resistance all day. Because the DC fan is built across 12V, 24V and 48V versions, plant designers cover automation cabinets and telecom shelves from the same series.

Key Features & Benefits

0.45 in H₂O Pressure Ceiling – The DC fan was drawn for restricted paths. Filters, foam and long ducts eat pressure, and this unit keeps useful airflow once they do.

90–150 CFM Airflow – Volume and pressure arrive together, so the DC fan can ventilate a large cabinet while still driving air through its densest components.

Nine-Blade Impeller – More blades mean smaller gaps between passes of the blade tip, which raises pressure for a given frame and smooths the sound profile of the DC fan.

PWM and Tach Wiring – Controllers can slow the DC fan when load falls, or watch its tach output to confirm the unit is turning as expected.

60,000 Hour Ball Bearings – The races inside the DC fan are sized for continuous duty, so the unit holds its rating in cabinets that never see a cool night.

Auto-Restart Electronics – Dust that jams the rotor no longer ends the life of the DC fan; the drive releases, waits and retries until the impeller turns again.

Technical Specifications Table
Technical Parameter Specification Value
Product Type 120mm High-Pressure DC Axial Fan
Model Number LB12038-HP
Frame Size 120 × 120 × 38 mm
Rated Voltage 12V / 24V / 48V DC
Speed Range 1,500–3,000 RPM
Airflow 90–150 CFM
Static Pressure 0.45 in H₂O max.
Noise Level 35–48 dBA
Lead Options 2-wire, 3-wire tach, 4-wire PWM
Life Expectancy Up to 60,000 hours
Bearings Ball bearings
Material PBT 9 fan blade
Motor life 50000 hours
Insulation level Class A
Working temperature -20℃~60℃
Weight 301.5g
Engineering Advantages & Professional Analysis

Filter loading is the silent killer of cabinet cooling. A clean filter costs a few pascals of pressure; a loaded one can multiply that figure several times over, and the DC fan caught behind it loses airflow exactly when the equipment needs it most. Sizing this DC fan with pressure in reserve means the working point of the DC fan stays inside the useful part of the curve between maintenance visits, and cabinet temperature does not climb just because a cleaner missed a round.

Balance and bearing load close the case. A nine-blade impeller turning at 3,000 RPM carries more rotating mass than a shallow unit, so the moulding has to be symmetrical and the bearings sized for the extra load. That is why the DC fan uses a machined shaft and preloaded races rather than the cheapest bearing the market offers, and why the DC fan will still be outside its wear window when the equipment around it has been refurbished twice.

image.png

Target Applications

This DC fan is specified where air has to travel or squeeze:

  • Filtered control cabinets: the DC fan holds flow as inlet media loads with dust.
  • Servers and industrial PCs: the DC fan clears dense components behind front grills.
  • Telecom rectifiers: the DC fan drives air down a short duct into a hot shelf.
  • Inverter and drive enclosures: the DC fan pushes through heatsink channels cut from extruded aluminium.
  • Textile, woodworking and packaging lines: the DC fan copes with lint and cardboard dust that clog ordinary fans.

Dirty workshops and sealed ducts are the natural home of a pressure-first DC fan. LOBISONG can supply samples of the unit, so a plant engineer can log how the DC fan behaves against the actual filter and duct the machine will carry.

image.pngimage(4a1e3932f8).png

Commercial Value & B2B ROI

Two costs dominate cabinet cooling: electricity and maintenance. A pressure-capable DC fan wins on both, because it keeps a lower speed for the same result and needs fewer cleaning cycles to stay effective. That translates into fewer callouts per year, and a service regime based on inspection rather than temperature alarms. A DC fan that survives a dusty plant also protects the warranty budget, since fewer replacements mean fewer claims. LOBISONG builds the DC fan on the same line as its other axial models, so OEM customers can bundle several sizes under one purchase order and one test report.

Frequently Asked Questions (FAQ)

How does the DC fan behave when the filter is fully loaded?
Airflow drops, but the DC fan keeps a working point because its pressure ceiling is high. Change the filter at that point and the DC fan returns to its rated flow.

Which frame suits a ducted run?
The 38mm depth used here. A DC fan designed for free-air duty will lose far more volume pushing down the same duct.

Is a controller needed to run the DC fan?
No. A two-wire build spins as soon as power is applied. Add a PWM lead only when the system should vary the speed of the DC fan with load.

image(5d87b78bf7).pngimage(dcbc0496bd).png

LOBISONG DC Fan LB12038-HP 120×120×38mm

The LOBISONG LB12038-HP is a 120×120×38mm brushless DC axial fan built for high-static-pressure cooling. Its deeper 38mm frame and optimized impeller push air through dense heatsinks, filters, and ducts, ideal for servers, telecom rectifiers, power supplies, inverters, and industrial cabinets.

Request a Quote

Featured Products

lobisong dc fan lb12038 hp 12012038mm-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000