LBBE3G310-092NS-22 EC medium-pressure backward curved centrifugal blower, galvanized/aluminum rotor, 2678m³/h at 175W, 73-85dB for plant cooling.
The LBBE3G310-092NS-22 is a 310mm EC backward curved centrifugal blower built around a low-speed, large-diameter rotor for workshop cooling and general exhaust. Its galvanized sheet or aluminum alloy impeller is driven by a brushless EC motor rated at 175W, producing 2678 m³/h at 1500 r/min in medium-pressure operation with noise registered at 73–85 dB. Sealing reaches IP55 or IP44 depending on the chosen variant, wings are Class F insulated, duty is S1 continuous across -25℃ to +60℃, and the unit runs on 400V/230V 50/60Hz. This blower opens a four-model 310mm family that climbs from 175W to a 1588W fire smoke exhaust variant reaching 5593 m³/h, so integrators can match a single platform across light cooling, heavy plant exhaust and emergency smoke extraction.
| Model | Power | Speed | Air Flow |
| LBBE3G310-092NS-22 | 175W | 1500 r/min | 2678 m³/h |
| LBBE3G310-092NS-23 | 220W | 2050 r/min | 2524 m³/h |
| LBBE3G310-102NT-24 | 1100W | 3000 r/min | 1100 m³/h |
| LBBE3G310-138NT-25 | 1588W | 3300 r/min | 5593 m³/h |
Rather than chasing high rpm to move air, this EC blower spreads its output over a 310mm impeller, reaching 2678 m³/h at only 1500 r/min. A lower tip speed reduces the broadband blade-pass whine that small high-speed wheels produce, and the large rotor pushes a broad airflow plume suited to workshop make-up air and machine cooling. The backward-inclined blade profile generates static pressure against filters and duct runs, so output does not collapse once the system sees resistance. Both galvanized sheet and aluminum alloy rotor options are offered: galvanized suits general dusty air, while aluminum adds lightness and corrosion resistance in finer airstreams.
A brushless electronically commutated motor forms the drive core of this 175W unit, removing brushes and commutator from the wear list. The controller keeps efficiency high when rpm drops, allowing the blower to be trimmed to actual heat load instead of running flat out behind a throttling damper. Variable speed also provides soft current ramp-up at startup, easing stress on contactors and plant circuits, and the EC architecture supports future control integration such as thermostat or pressure-sensor linkage in packaged ventilation units.






The family ships in two sealing grades to match the installation environment without paying for unused protection. IP55 units resist fine dust ingress and directional splashing for grinding bays, dusty floors and semi-outdoor plant rooms; IP44 units protect against coarse particles and light splash in enclosed cabinets and ducted positions. Sealed housings keep dust away from the Class F windings and ball bearings, preserving airflow consistency over years of daily use where an open-frame motor would accumulate grit and lose output.
Class F insulation gives the windings reserve heat capacity for sustained full-load running, an important factor when the blower sits inside a closed plenum that limits motor self-cooling. Rated from -25℃ to +60℃, the unit handles cold unheated plants and warm summer workshops without derating, and S1 duty confirms it is engineered for non-stop operation rather than short intermittent bursts. The 400V/230V dual-voltage 50/60Hz input covers three-phase European sites and 230V commercial grids from one model line.
Four power tiers share the same 310mm envelope and 3 kg frame, standardizing the duct collar, mounting holes and housing fitment across projects. The NS-22 at 175W and 2678 m³/h covers standard workshop cooling; the NS-23 at 220W and 2524 m³/h handles comparable factory duty; the NT-24 at 1100W serves kitchen exhaust; the NT-25 at 1588W and 5593 m³/h delivers high-volume fire smoke extraction. Ball bearings are sealed and relubrication-free, and each unit carries CE, RoHS, ETL, BSCI, CCC and ISO certification, with OEM/ODM customization available for bulk orders.


Q: How much air does the NS-22 move? A: This unit delivers 2678 m³/h at 1500 r/min on 175W, classified as a medium-pressure blower for standard factory cooling and moderate-resistance ducted ventilation.
Q: What noise level should I plan for? A: The blower's rated noise range is 73–85 dB. Lower-speed operation and ducting or enclosure separation can reduce the noise reaching occupied zones; speed trimming further lowers noise during light-load periods.
Q: Which variants sit on the same 310mm frame? A: The NS-23 gives 2524 m³/h at 220W; the NT-24 gives 1100 m³/h at 1100W; the NT-25 gives 5593 m³/h at 1588W for smoke exhaust. All share the 310mm impeller platform and 3 kg frame, with galvanized or aluminum rotor options.
LBBE3G310-092NS-22 EC medium-pressure backward curved centrifugal blower, galvanized/aluminum rotor, 2678m³/h at 175W, 73-85dB for plant cooling.