LBBE3G310-092NS-20 EC Cleanroom Fan

LBBE3G310-092NS-20 EC low-pressure backward curved centrifugal blower, 7-blade rotor, 2235m³/h at 160W, quiet cleanroom ventilation.

Request a Quote
  • Overview

Overview

Product Overview

Built around a 310mm seven-blade rotor, the LBBE3G310-092NS-20 is an EC brushless backward curved centrifugal blower intended for cleanroom make-up air, cabinet ventilation and heat dissipation. Its 160W EC motor turns the rotor at 1850 r/min to deliver 2235 m³/h of low-pressure airflow, with noise held between 70 and 80 dB. Sealed to IP54 or IP44 depending on variant, Class F insulated and rated S1 continuous duty from -25℃ to +60℃, the unit runs on 230V 50/60Hz. This model opens a three-branch 310mm family that also covers a 150W light-duty blower and a 360W mid-range unit, letting integrators standardize one housing across purification and cooling projects. 

Model Power Speed Air Flow
LBBE3G310-92NS-20 160 W 1850 r/min 2235 m³/h
LBBE3G310-92NS-17 150W 1750 r/min 2410 m³/h
LBBE3G310-102NS-16 360W 2149 r/min 2869 m³/h

Product Advantages

1. Quiet Operation Suited to Occupied Rooms

Keeping noise acceptable in occupied cleanrooms and support zones is a primary requirement, and this backward curved centrifugal fan is tuned around that constraint. The seven-blade rotor spreads each airflow pulse across more blade passes, avoiding the harsh discrete whine produced by fewer, heavier blades, while the 1850 r/min running speed keeps tip velocity moderate. The result is a 70–80 dB operating band that pairs acceptably with enclosure or duct attenuation, and speed trimming can lower the unit further during light occupancy when quiet running matters most.

2. Low-Pressure Rotor Matched to Filters and Grilles

For cleanroom and purifier applications, resistance comes mainly from pre-filters, panel grilles and short duct runs rather than long high-pressure risers. This backward curved centrifugal fan is built as a low-pressure blower, moving 2235 m³/h against that light-to-moderate resistance without oversizing the motor. The backward-inclined blade profile keeps airflow stable as filters gradually load, and the 310mm rotor delivers a broad, even airflow plume that distributes across the room or cabinet rather than concentrating on one spot.

3. Brushless EC Motor, Maintenance-Light Drive

The 160W drive core is a brushless EC motor with no brushes to wear or replace, which removes one of the common failure points in continuously running ventilation equipment. The controller maintains good efficiency at reduced speed, so the blower can follow actual temperature or occupancy instead of being throttled by a damper that discards fan energy as pressure loss. Soft-start current ramp protects supply circuits at switch-on, and sealed ball bearings mean the routine service list stays limited to inspection rather than relubrication.

Product Overview

Product OverviewProduct Overview

Product Overview

4. Sealed Enclosure for Dusty or Protected Cabinets

Two enclosure grades cover the common installation styles. IP54 protects against particles above 1mm and splashing water in plant rooms and semi-protected interiors; IP44 suits enclosed purifier cabinets, ceiling plena and ducted positions behind panels. The sealed housing keeps dust and incidental moisture away from the Class F windings and bearing, preserving airflow consistency over daily use where an open-frame motor would accumulate grit and gradually lose output.

5. Shared Platform Across Three Output Levels

The NS-20, NS-17 and NS-16 models keep the same 310mm impeller envelope, so the duct collar, mounting holes and housing dimensions can be held constant while output varies by project. The 160W NS-20 and 150W NS-17 cover light purification and cooling duty; the 360W NS-16 handles mid-range airflow in larger cabinets or rooms. Every variant uses sealed ball bearings, S1 duty and the same insulation and temperature rating, and carries ISO, BSCI, ETL, CE, EMC, RoHS and GS certification, with OEM/ODM options available for bulk orders. 

Product Overview

Product Overview

Application Scenarios

  • Light Cleanroom and Laboratory Ventilation: The blower supplies general make-up air and circulation in lightly controlled rooms, preparation areas and assembly zones where quiet running and steady filtered airflow are required.
  • Equipment and Panel Cooling: Mounted beside drives, power supplies and control electronics, it directs low-pressure airflow onto heat sinks to keep components inside rated temperature limits.
  • Purifier and Filter Cabinets: Inside standalone purifiers and ducted filter boxes, the backward curved centrifugal fan pulls air through pre-filters and distributes it back to the room.
  • Packaged Air-Handling Modules: System builders reuse the 310mm frame in air handlers and dust collectors, taking advantage of the common mounting interface and two enclosure grades.

Frequently Asked Questions

Q: How much air does the NS-20 move? A: This backward curved centrifugal fan delivers 2235 m³/h at 1850 r/min on 160W, a low-pressure rating for standard cleanroom ventilation and equipment cooling with light duct or filter resistance.

Q: Can the fan run continuously and be speed-adjusted? A: Yes. S1 continuous duty and sealed ball bearings support non-stop running, and the EC motor allows stepless speed adjustment to match airflow and noise to the actual room load.

Q: What other outputs share this frame? A: The NS-17 provides 2410 m³/h at 150W, and the NS-16 provides 2869 m³/h at 360W. All three use the same 310mm rotor platform and protection, insulation and temperature ratings.

LBBE3G310-092NS-20 EC Cleanroom Fan

LBBE3G310-092NS-20 EC low-pressure backward curved centrifugal blower, 7-blade rotor, 2235m³/h at 160W, quiet cleanroom ventilation.

Request a Quote

Featured Products

lbbe3g310 092ns 20 ec cleanroom fan187-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000