LBBE3G250-092NS-12 EC backward curved centrifugal fan, PA66 impeller, IP54/IP44, 1531m³/h at 140W for FFU filter units and cleanroom ventilation.
The LBBE3G250-092NS-12 is a 250mm EC backward curved centrifugal fan engineered for FFU filter unit assemblies and factory cleanroom ventilation. Built around a PA66 engineering plastic impeller and a brushless EC motor, this backward curved centrifugal fan delivers 1531 m³/h at 3010 r/min on 140W shaft power, holding steady airflow against HEPA and pre-filter resistance while keeping noise and energy draw within practical daily limits. The unit is sealed to IP54/IP44, insulated to Class F/B, wired for 230V/115V 50/60Hz, and rated S1 continuous operation from -25℃ to +60℃. Within this five-variant 250mm NS/NU family, this backward curved centrifugal fan sits as a mid-high output model, matched to standard FFU housings, cleanroom ceiling grids and general factory heat dissipation.
| Model | Power | Speed | Air Flow |
| LBBE3G250-092NS-12 | 140W | 3010 r/min | 1531m³/h |
| LBBE3G250-072NU-20 | 160W | 2760r/min | 1331m³/h |
| LBBE3G250-072NS-21 | 140W | 2760 r/min | 1421m³/h |
| LBBE3G250-092NS-23 | 170W | 2600 r/min | 1421m³/h |
| LBBE3G250-072NS-29 | 90W | 2150 r/min | 1215m³/h |








The core of this backward curved centrifugal fan is a 250mm PA66 engineering plastic impeller with a backward-inclined blade path shaped for the pressure drop of real filter stacks. A backward curved centrifugal fan converts rotational speed into static pressure rather than raw velocity, so it keeps 1531 m³/h flowing after air crosses a pre-filter and a HEPA panel instead of stalling as media loads. That pressure capability is the main reason this backward curved centrifugal fan is chosen for FFU modules rather than free-delivery axial blowers. PA66 holds blade geometry through long duty cycles without heat softening, and the balanced rotor limits wake turbulence and outlet noise in cleanrooms where occupied spaces sit directly below ceiling grids.
This backward curved centrifugal fan runs on a brushless EC motor rated at 140W, which keeps full-speed airflow generous while still allowing efficient part-load operation. The drive stays efficient when rpm drops, so this backward curved centrifugal fan can be held at reduced speed during low-occupancy shifts instead of cycling on and off. Speed is steplessly adjustable, letting a building controller ramp the backward curved centrifugal fan up as particle load rises and settle it back down after a filter change. Because fan power falls roughly with the cube of speed, modest speed trims produce substantial savings on units that run around the clock.
Offered in IP54 or IP44 protection grades, this FFU centrifugal fan covers two installation environments without over-specifying the housing. The tighter IP54 build keeps fine particulate and occasional splash out of the windings in dusty factory production areas; the IP44 option suits protected cleanroom cabinets and ducted housings where only coarse dust is present. Because the motor is sealed, this backward curved centrifugal fan can be installed without an auxiliary enclosure, which keeps FFU ceiling modules thin and makes retrofit into existing frames straightforward.
Insulation is rated Class F/B, giving this backward curved centrifugal fan winding headroom under sustained load, which matters when the motor sits inside a thin FFU plenum with limited cooling flow around it. The declared -25℃ to +60℃ ambient range covers cold warehouse areas, unheated workshops and warm plant rooms without derating, and S1 duty means this backward curved centrifugal fan is specified for non-stop operation rather than intermittent switching. The 230V/115V 50/60Hz input lets the same backward curved centrifugal fan serve both European 230V and North American 115V installations, so OEMs do not stock separate motor variants per region.
Every model in this series shares a 250mm impeller diameter and a 2 kg frame, so one ceiling cut-out or cabinet opening accepts any of them. Designers keep the mechanical envelope fixed and size airflow to the job: this 092NS-12 backward curved centrifugal fan at 140W and 1531 m³/h for FFU and cleanroom use, the 072NU-20 at 160W and 1331 m³/h for hotel ventilation, the 072NS-21 at 140W and 1421 m³/h for air conditioning cabinets, the 092NS-23 at 170W and 1421 m³/h for heavier factory exhaust, and the 072NS-29 at 90W and 1215 m³/h for light factory ventilation. That common footprint lets a single backward curved centrifugal fan reference cover several product lines, and each unit ships with CE, RoHS, ETL, BSCI, CCC and ISO certification on maintenance-free sealed ball bearings.


Q: Is this fan suitable for FFU applications? A: Yes. This backward curved centrifugal fan builds static pressure so it holds 1531 m³/h through HEPA media, and its 140W EC motor with stepless speed control lets an FFU match airflow to actual particle load while keeping noise and power draw low.
Q: How does the 092NS-12 compare with the other 250mm variants? A: It is a mid-high unit at 140W and 1531 m³/h. The 072NU-20 gives 1331 m³/h at 160W, the 072NS-21 gives 1421 m³/h at 140W, the 092NS-23 gives 1421 m³/h at 170W, and the 072NS-29 gives 1215 m³/h at 90W. All five share a 250mm impeller and 2 kg frame.
Q: Can it run on 115V and 230V, and operate continuously? A: Yes to both. The rated input is 230V/115V at 50/60Hz, and this backward curved centrifugal fan is IP54/IP44 sealed, S1 continuous duty, built for non-stop running within the -25℃ to +60℃ ambient range.
LBBE3G250-092NS-12 EC backward curved centrifugal fan, PA66 impeller, IP54/IP44, 1531m³/h at 140W for FFU filter units and cleanroom ventilation.