LBBE3G250-072PS-15 EC backward curved centrifugal fan, PA66 impeller, IP54/IP44, 1215m³/h at 90W for quiet kitchen exhaust and ventilation.
The LBBE3G250-072PS-15 is a 250mm EC backward curved centrifugal fan built for general ventilation and commercial kitchen exhaust duty. Paired with a PA66 engineering plastic impeller and a brushless EC motor, this backward curved centrifugal fan delivers 1215 m³/h at 2150 r/min on only 90W shaft power, providing steady exhaust airflow with low noise and modest energy draw through long daily operating hours. The unit is sealed to IP54/IP44, insulated to Class F/B, wired for 230V/115V 50/60Hz, and rated S1 continuous operation across a -25℃ to +60℃ ambient range. Within this four-variant 250mm PS family, this backward curved centrifugal fan is the entry kitchen model, matched to standard hoods, ducted exhaust and general air exchange units.
| Model | Power | Speed | Air Flow |
| LBBE3G250-072PS-15 | 90W | 2150 r/min | 1215m³/h |
| LBBE3G250-092PS-16 | 140W | 3010 r/min | 1531m³/h |
| LBBE3G250-072PS-17 | 140W | 2760 r/min | 1421m³/h |
| LBBE3G250-092PS-21 | 1700W | 2600 r/min | 1421m³/h |




The heart of this backward curved centrifugal fan is a 250mm PA66 engineering plastic impeller molded with a backward-inclined blade path. A backward curved centrifugal fan converts rotational speed into static pressure rather than raw velocity, so it keeps 1215 m³/h moving after air crosses a grease baffle, a hood plenum and a length of ductwork. That pressure capability is what separates this backward curved centrifugal fan from free-delivery axial fans that lose throughput once resistance rises. PA66 resists grease adhesion, heat aging and dust wear, keeping blade geometry stable over long duty cycles, and the balanced rotor limits turbulence and blade-outlet noise in occupied commercial spaces.
This backward curved centrifugal fan runs on a brushless EC motor rated at 90W, and that low input figure is what keeps daily ventilation economical. The drive stays efficient at part load, so this backward curved centrifugal fan can be held at reduced rpm during light-use periods instead of cycling on and off. Speed is steplessly adjustable, letting a controller ramp the backward curved centrifugal fan up as fume or heat load rises and settle it back down after peak demand. Because fan power falls roughly with the cube of speed, even a modest rpm trim produces noticeable savings on a unit that runs through full commercial hours.



Offered in IP54 or IP44 protection grades, this ventilation centrifugal fan covers two common mounting zones without over- or under-specifying sealing. The tighter IP54 build keeps fine dust and splash out of the windings where the unit sits near cooking lines or dusty production floors; the IP44 option suits protected indoor cabinets and ducted housings where only coarse dust is present. Because the motor housing is sealed, this backward curved centrifugal fan needs no auxiliary enclosure, which simplifies hood design and reduces the parts count in a packaged exhaust or ventilation unit.
Insulation is rated Class F/B, giving this backward curved centrifugal fan winding headroom under sustained load, which matters when the motor sits inside a hood or plenum that traps heat around itself. The declared -25℃ to +60℃ ambient range covers cold-season unheated kitchens, warm plant rooms and seasonal commercial spaces without derating, and S1 duty means this backward curved centrifugal fan is specified for non-stop operation rather than intermittent switching. The 230V/115V 50/60Hz input lets the same backward curved centrifugal fan ship into both European 230V and North American 115V markets, so OEMs do not need separate SKUs per region.
Every model in this PS series shares a 250mm impeller diameter and a 2 kg frame, so one duct collar or cabinet opening accepts any of them. Designers fix the mechanical envelope and size airflow to the job: this 072PS-15 backward curved centrifugal fan at 90W and 1215 m³/h for standard kitchen exhaust and general ventilation, the 092PS-16 at 140W and 1531 m³/h for factory exhaust, the 072PS-17 at 140W and 1421 m³/h for heavier kitchen duty, and the 092PS-21 at 170W and 1421 m³/h for high-capacity kitchen exhaust. That common footprint lets a single backward curved centrifugal fan reference cover several product lines, and each unit ships with CE, RoHS, ETL, BSCI, CCC and ISO certification, supported by maintenance-free sealed ball bearings.

Q: Is 1215 m³/h enough for a commercial kitchen hood? A: For standard hoods, yes. This backward curved centrifugal fan delivers 1215 m³/h at 2150 r/min on 90W, covering ordinary commercial cooking lines. For longer ducts or heavier filtration, the 072PS-17 and 092PS-21 models step up to 1421 m³/h, and the 092PS-16 reaches 1531 m³/h.
Q: Can this fan run on 115V or 230V? A: Yes. The rated input is 230V/115V at 50/60Hz, so this backward curved centrifugal fan can serve both North American 115V and European 230V installations without a separate motor variant.
Q: Is speed adjustable and can it run continuously? A: Both. The EC motor supports stepless speed regulation so output can follow real fume and heat load, and the unit is rated S1 continuous operation with sealed ball bearings for non-stop running within the -25℃ to +60℃ range.
LBBE3G250-072PS-15 EC backward curved centrifugal fan, PA66 impeller, IP54/IP44, 1215m³/h at 90W for quiet kitchen exhaust and ventilation.