250mm EC backward curved centrifugal fan with PA66 impeller, IP55 rated, 1185m³/h at 85W for FFU air purifiers and new energy heat dissipation.
The LBE3G250-072NS-08 is a 250mm EC backward curved centrifugal fan designed for FFU air purification modules and new energy equipment heat dissipation. Built around a PA66 engineering plastic impeller and driven by a brushless EC motor, this backward curved centrifugal fan holds 1185 m³/h at 1810 r/min while drawing only 85W shaft power, which keeps a filter unit's running cost and acoustic footprint low even when it operates around the clock. The unit is sealed to IP55, insulated to Class F, wired for 230V 50/60Hz, and rated S1 continuous duty from -25℃ to +60℃. Within this four-variant 250mm series, this backw ard curved centrifugal fan is the entry model, matched to standard FFU housings rather than high-pressure plant ductwork.
| Model | Power | Speed | Air Flow |
| LBBE3G250-072NS-08 | 85W | 1810 r/min | 1185m³/h |
| LBBE3G250-072NS-09 | 169W | 2570 r/min | 1478m³/h |
| LBBE3G250-072NS-18 | 115W | 2180 r/min | 1236m³/h |
| LBBE3G250-092NS-19 | 230W | 2700 r/min | 1648m³/h |
The core of this backward curved centrifugal fan is a 250mm PA66 engineering plastic impeller molded with a backward-inclined blade path tuned for the pressure drop of real filter stacks. A backward curved centrifugal fan converts rotational speed into static pressure rather than raw velocity, so it keeps 1185 m³/h flowing after air has crossed a pre-filter and a HEPA panel. That pressure capability is what separates this backward curved centrifugal fan from axial fans that lose throughput as media loads. PA66 holds blade geometry through long duty cycles without heat softening, and the balanced rotor keeps outlet turbulence low so a filter module does not transmit broadband noise into a cleanroom.
This backward curved centrifugal fan runs on a brushless EC motor rated at 85W, and that low figure is what makes continuous FFU operation economical. The drive stays efficient at part load, so this backward curved centrifugal fan can be held at reduced rpm during low-occupancy hours instead of cycling on and off. Speed is steplessly adjustable, meaning a controller can ramp the backward curved centrifugal fan up as filter resistance rises and settle it back down after a filter change. Because fan power falls roughly with the cube of speed, even a modest reduction in rpm produces a large saving on a unit that runs twenty-four hours a day.





Rated IP55, this backward curved centrifugal fan keeps dust and splashing water out of the windings and bearings. That protection matters in two very different installations: cleanroom FFU ceiling grids that are periodically wiped down, and new energy battery or power electronics rooms where fine conductive dust circulates. Because the motor housing is fully sealed, this backward curved centrifugal fan can be installed without an auxiliary enclosure, which keeps FFU modules thin and simplifies retrofit into existing ceiling frames.
Class F insulation gives this backward curved centrifugal fan thermal reserve under sustained load, which is important inside FFU housings where airflow around the motor is restricted. The declared -25℃ to +60℃ ambient range covers cold storage areas, unheated warehouses and warm plant rooms without derating, and the S1 duty rating means this backward curved centrifugal fan is specified for non-stop service rather than intermittent switching. The 230V 50/60Hz input lets the same backward curved centrifugal fan ship into both 50Hz and 60Hz markets, so OEMs do not need separate SKUs per region.
Every model in this 250mm series shares the same impeller diameter and 2 kg frame, so one ceiling cut-out or cabinet opening accepts any of them. Designers keep the mechanical envelope fixed and pick output to the job: this 072NS-08 backward curved centrifugal fan at 85W and 1185 m³/h for standard FFU modules, the 072NS-09 at 169W and 1478 m³/h for hotel ventilation, the 072NS-18 at 115W and 1236 m³/h for air conditioning cabinets, and the 092NS-19 at 230W and 1648 m³/h for heavier factory exhaust. That single footprint means one backward curved centrifugal fan reference can cover several product lines, and each unit ships with CE, RoHS, ETL, BSCI, CCC and ISO certification.


Q: Is this fan suitable for FFU applications? A: Yes. This backward curved centrifugal fan builds static pressure so it holds 1185 m³/h through HEPA media, and its 85W EC motor with stepless speed control allows an FFU to match airflow demand precisely while keeping noise and power draw low.
Q: How does the -072NS-08 compare with the other 250mm variants? A: It is the lowest-power unit at 85W and 1185 m³/h. The 072NS-09 gives 1478 m³/h at 169W, the 072NS-18 gives 1236 m³/h at 115W, and the 092NS-19 gives 1648 m³/h at 230W. All four share a 250mm impeller and a 2 kg frame.
Q: Can it run continuously in a cleanroom or battery plant? A: Yes. This backward curved centrifugal fan is rated IP55 and S1 continuous duty, so it is built for non-stop running within the -25℃ to +60℃ ambient range, with sealed ball bearings that need no relubrication.
250mm EC backward curved centrifugal fan with PA66 impeller, IP55 rated, 1185m³/h at 85W for FFU air purifiers and new energy heat dissipation.