LBBE3G225-072PS-11 EC Kitchen Exhaust Fan

LBBE3G225-072PS-11 EC backward curved centrifugal fan, PA66 impeller, IP54/IP44 sealing, 1112m³/h at 80W for quiet kitchen fume extraction.

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G225-072PS-11 is a 225mm EC backward curved centrifugal fan built for kitchen fume extraction where quiet operation and low running cost matter as much as airflow. As a backward curved centrifugal fan driven by a PA66 engineering plastic impeller, it delivers 1112 m³/h at 2500 r/min while drawing only 80W shaft power, so a hood can run through an entire service without the energy bill or the motor hum that fixed-speed AC blowers bring. The unit is sealed to IP54/IP44, insulated to Class F/B, wired for 230V 50/60Hz, and rated S1 continuous duty across a -25℃ to +60℃ ambient range. Within this three-variant 225mm PS family, this backward curved centrifugal fan is the low-power kitchen model, matched to standard commercial hoods and compact exhaust units.

Model Power Speed Air Flow
LBBE3G225-072PS-11 80W 2500 r/min 1112m³/h
LBBE3G225-092PS-12 156W 3060 r/min 1528m³/h
LBBE3G225-092PS-13 190W 3000 r/min 1545m³/h

Product Advantages

1. PA66 Impeller That Holds Up in Greasy Air

The heart of this backward curved centrifugal fan is a 225mm PA66 engineering plastic impeller. PA66 tolerates grease, heat cycling and chemical exposure far better than low-cost plastics, so the blade surfaces stay clean and the airflow curve stays predictable after months of pulling oil-laden kitchen air. Because a backward curved centrifugal fan builds static pressure rather than sheer velocity, it still delivers 1112 m³/h once air has passed a grease baffle, a hood plenum and a run of duct. The molded blade path also smooths outlet turbulence, which is where most of the broadband noise in a hood originates.

2. 80W EC Drive for Quiet, Cheap Continuous Duty

This backward curved centrifugal fan uses a brushless EC motor rated at just 80W, and that low figure is why it suits hoods that operate through a full day. The EC drive stays efficient at part load, so the backward curved centrifugal fan can be held at reduced rpm during light cooking instead of cycling on and off. Speed is steplessly adjustable, letting the exhaust controller ramp the backward curved centrifugal fan up as fume load climbs and settle it back down when the kitchen quiets. Lower rpm means less motor hum reaching open-plan dining areas, and less blade noise at the hood outlet.

Product Overview

Product Overview

Product Overview

Product Overview

3. IP54 / IP44 Sealing for Hood and Cabinet Mounting

Kitchens punish motors with grease mist, flour dust and washdown splashes, and this backward curved centrifugal fan is sealed to IP54 or IP44 to suit the mounting zone. The tighter IP54 build keeps fine particulate and splash out of the windings, which is what a backward curved centrifugal fan needs when it sits close to the cooking line. The IP44 option covers protected indoor cabinets and ducted housings where only coarse dust is present, so a single backward curved centrifugal fan platform can serve both exposed hoods and enclosed exhaust boxes without over-specifying sealing.

4. Class F/B Insulation and 50/60Hz Flexibility

Insulation is rated Class F/B, giving the winding thermal headroom in a plenum that traps heat around the motor, and the rating covers the declared -25℃ to +60℃ ambient window. The 230V 50/60Hz input lets the same backward curved centrifugal fan ship into 50Hz and 60Hz markets, which reduces SKU count for exporters and OEMs building hoods for several regions. Sealed ball bearings and an S1 duty rating mean the backward curved centrifugal fan is specified for non-stop operation with no relubrication interval, so service visits stay rare over a long installed life.

5. Three Output Steps on One 225mm Footprint

Every model in this PS series shares a 225mm impeller diameter and a 2 kg frame, so one hood cut-out accepts any of them. A designer can fix the mechanical envelope and choose output by load: this 072PS-11 backward curved centrifugal fan at 80W and 1112 m³/h for standard kitchen hoods, the 092PS-12 at 156W and 1528 m³/h for factory exhaust, and the 092PS-13 at 190W and 1545 m³/h for heavier factory ventilation. That common platform lets a single backward curved centrifugal fan reference cover several product lines, and each unit ships with ISO, BSCI, ETL, CE, EMC, RoHS and GS certification.

Product Overview

Product Overview

Application Scenarios

  • Commercial Kitchen Hood Exhaust: This backward curved centrifugal fan is the air-moving core of range hoods and under-cabinet extractors in restaurants, canteens and food courts, pulling fume and steam away from workstations while keeping noise low enough for open dining rooms.
  • Fume Extraction with Grease Filtration: Because a backward curved centrifugal fan maintains pressure across filter media, it performs well behind baffle filters and multi-stage grease separators, where free-delivery fans lose extraction rate as media loads.
  • Packaged Exhaust Fan Units: OEMs building compact exhaust units favor this backward curved centrifugal fan for its 2 kg frame, IP54/IP44 sealing options and 230V 50/60Hz compatibility, which let one housing serve multiple export markets.
  • Light Industrial Exhaust Ventilation: In staff canteens tied to production floors and in food processing rooms where cooking and process fumes mix, this backward curved centrifugal fan provides steady low-power extraction without the noise penalty of high-speed blowers.

Frequently Asked Questions

Q: Is 1112 m³/h enough for a commercial hood? A: For standard hoods, yes. This backward curved centrifugal fan delivers 1112 m³/h at 2500 r/min on 80W, covering ordinary commercial cooking lines. For long ducts or heavy filtration, the 092PS-12 and 092PS-13 models step up to 1528 and 1545 m³/h.

Q: Will grease mist damage the motor? A: The motor is sealed to IP54 or IP44 depending on the version ordered, keeping grease mist and dust away from windings and bearings, while the PA66 impeller resists grease adhesion on blade surfaces. That combination is why this backward curved centrifugal fan suits continuous kitchen duty.

Q: Is speed adjustable and can it run all day? A: Both. The EC motor supports stepless speed regulation so output can follow real fume load, and the unit is rated S1 continuous operation with sealed ball bearings for non-stop running within the -25℃ to +60℃ rage.

LBBE3G225-072PS-11 EC Kitchen Exhaust Fan

LBBE3G225-072PS-11 EC backward curved centrifugal fan, PA66 impeller, IP54/IP44 sealing, 1112m³/h at 80W for quiet kitchen fume extraction.

Request a Quote

Featured Products

lbbe3g225 072ps 11 ec kitchen exhaust fan-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000