LBBE3G225-072NS-07 EC Air Purifier Fan

Request a Quote
  • Overview

Overview

Product Overview

The LBBE3G225-072NS-07 is a 225mm EC backward curved centrifugal fan built for air purification equipment and factory ventilation systems that demand high airflow against filter and duct resistance. It pairs a PA66 engineering plastic impeller with a brushless EC motor, delivering 1313 m³/h at 3100 r/min with 170W shaft power. Rated IP55 with Class F insulation, it runs on 230V 50/60Hz and holds up across a -25℃ to +60℃ ambient range under S1 continuous duty. As the highest-airflow model in this four-variant 225mm series, it is the choice when a filtration unit needs enough static pressure to push air through HEPA or activated carbon media without losing throughput.

Model Power Speed Air Flow
LBBE3G225-072NS-07 170W 3100 r/min 1313m³/h
LBBE3G225-072NS-10 80W 2500 r/min 1112m³/h
LBBE3G225-092NS-11 85W 2300 r/min 1009m³/h
LBBE3G225-072NS-13 115W 2600 1185m³/h

Product Advantages

1. PA66 Backward Curved Impeller for Filter-Load Airflow

This EC backward curved centrifugal fan uses a 225mm precision-molded PA66 impeller with a backward-inclined blade profile tuned for the pressure loss of real filtration systems. Backward curved blades convert rotational speed into static pressure rather than raw velocity, so the fan keeps moving 1313 m³/h even after air passes through pre-filters, HEPA media and carbon beds. PA66 holds its geometry under sustained heat and vibration, resists aging, and keeps the blade path stable across long continuous runs. The balanced impeller also limits pneumatic noise, which matters because air purifiers typically sit in occupied rooms where fan noise is noticed.

2. 170W Brushless EC Drive with Stepless Speed Regulation

The motor is an electronically commutated brushless unit rather than a conventional AC induction motor, which means speed can be trimmed steplessly instead of switched between fixed taps. In an air purifier, that allows the controller to drop rpm as particulate load falls, cutting power consumption and noise in a way that a fixed-speed blower cannot. The EC drive also limits inrush current at startup, protecting control boards and relays in appliance-grade electronics. At full speed the unit produces 1313 m³/h with 170W input, a ratio that supports energy-labeled air purification products.

Product Overview

Product Overview

Product Overview

Product Overview

Product Overview

Product Overview

3. IP55 Sealing for Dusty and Washdown Environments

Rated IP55, this backward curved centrifugal fan blocks dust ingress and tolerates water splashing from any direction, which is more protection than typical indoor appliance fans provide. That matters in two common cases: factory ventilation where airborne particulate is constant, and filtration equipment that sees condensation or periodic cleaning. The sealed motor housing keeps particulate away from windings and bearings, so performance does not drift as dust accumulates, and service intervals stay long even in dirty airstreams.

4. Class F Insulation and a Wide Thermal Window

Class F insulation gives the winding headroom to handle temperature rise during sustained full-load operation without losing dielectric strength, which is important in air purifiers where housings can trap heat around the motor. The rated ambient window of -25℃ to +60℃ covers cold storage rooms, unheated warehouses and warm plant rooms alike without derating or derangement. The 230V 50/60Hz input lets one SKU serve both 50Hz and 60Hz markets, simplifying stock planning for exporters and OEMs building products for multiple regions.

5. Four Series Variants, Common 225mm Footprint

All four models in this family share the same 225mm impeller diameter and 2 kg frame, so a single mounting cut-out and duct interface can accept any of them. Designers can standardize the mechanical envelope and then choose output by load: the 072NS-07 at 170W and 1313 m³/h for high-resistance purification, the 072NS-10 at 80W and 1112 m³/h for hotel ventilation, the 092NS-11 at 85W and 1009 m³/h for AC cabinets, or the 072NS-13 at 115W and 1185 m³/h for kitchen exhaust. Sealed ball bearings run maintenance-free with no relubrication schedule, and units ship with CE, RoHS, ETL, BSCI, CCC and ISO certification.

Product Overview

Product Overview

Application Scenarios

  • Air Purifiers and Filtration Units: As the air-moving core of residential, commercial and industrial air purifiers, this backward curved centrifugal fan pushes air through multi-stage filter stacks where pressure drop is significant, holding rated clean air delivery as media loads up.
  • Factory Air Purification and Ventilation: Mounted in workshop purification units and general ventilation ducts, it moves 1313 m³/h against production-floor dust load, helping bring particulate levels down in manufacturing spaces.
  • HVAC Air Handling Compartments: Fits packaged air handling units, fan coil cabinets and purification modules where a compact 225mm blower must deliver directed airflow against coil and filter resistance.
  • Equipment and Enclosure Cooling: Suitable for heat dissipation in cabinets, control panels and process equipment where steady high-pressure airflow is required rather than free-delivery axial flow.

Frequently Asked Questions

Q: Is this fan suitable for air purifier applications? A: Yes. The backward curved PA66 impeller is designed to hold airflow against high filter resistance, and the brushless EC motor allows stepless speed control so the purifier can match fan output to actual particulate load. At full speed it delivers 1313 m³/h with 170W input.

Q: How does this model compare with the other 225mm variants? A: It is the highest-airflow unit in the family at 170W and 1313 m³/h. The 072NS-10 runs 80W for 1112 m³/h, the 092NS-11 runs 85W for 1009 m³/h, and the 072NS-13 runs 115W for 1185 m³/h. All four share the same 225mm impeller diameter and 2 kg frame.

Q: Is the speed adjustable, and can it run continuously? A: Yes to both. The EC brushless motor supports stepless speed regulation, and the unit is rated S1 continuous operation with sealed ball bearings, so it is built for non-stop duty inside the -25℃ to +60℃ ambient range.