Lobisong LBAA2D145S-5MNW-01 AC Axial Fan Ø145 mm — High-Efficiency Industrial Cooling Solution
When every millimeter inside an electrical cabinet matters, the cooling fan cannot be oversized—it must be efficient at its frame size. The Lobisong LBAA2D145S-5MNW-01 is a 145mm AC axial fan purpose-built for tight enclosures where a larger blower will not fit. Running on 380V three-phase at 2800 RPM, this 3-phase cabinet cooling fan moves 268 m³/h while emitting just 46 dB(A)—quiet enough for office-adjacent equipment rooms. Balanced to G6.3 and sealed to IP54, this high-efficiency low-noise fan is the answer for PLC cabinets, VFD enclosures, and telecom racks that need reliable through-flow cooling without workspace noise.

Compact-cooling engineers face a familiar trade-off: smaller frames spin faster to compensate, and faster spinning means more noise. The brief for this industrial axial fan was to break that trade-off. A cold-rolled sheet impeller at 2800 RPM draws 268 m³/h straight through the cabinet—the classic axial through-flow path that loses little energy turning corners.
Noise was engineered down, not tolerated. At 46 dB(A), this 145mm axial fan sits below typical office ambient, meaning a control panel in a reception area or a telecom enclosure in an office building triggers no noise complaints. G6.3 precision balancing per JB/T8689 keeps vibration and tonal whine minimal across the 2800 RPM range of this IP54 AC fan. The motor is Class F wound and IP54 protected, so workshop dust and occasional water spray will not shorten life. Maintenance-free ball bearings carry a 30,000-hour L10 rating—enough to outlast most equipment refresh cycles.
| Parameter | Value |
| Model | LBAA2D145S-5MNW-01 |
| Series | LWAA2D145 |
| Motor Type | AC, 3-phase |
| Voltage | 380V (range 342~418V) |
| Frequency | 50Hz |
| Current | 0.15 A |
| Power | 50 W |
| Speed | 2800 RPM |
| Max Airflow | 268 m³/h |
| Noise | 46 dB(A) |
| Ambient Temperature | -30°C ~ +60°C |
| Storage Temperature | -40°C ~ +80°C |
| Humidity | 0~95% RH |
| Altitude | < 1000 m |
| Impeller | Ø145mm cold-rolled sheet |
| Protection Rating | IP54 |
| Insulation Class | Class F |
| Bearing | Maintenance-free ball bearings |
| Duty | S1 |
| Balance Grade | G6.3 |
| Vibration Standard | JB/T8689 |
| Bearing Life | 30,000 h (L10) |
Why does a three-phase 145mm axial fan make sense for cabinet cooling when single-phase options are cheaper? Three-phase motors draw lower current for the same shaft power, run without a starting capacitor (the most common single-phase failure part), and produce a smoother rotating field. For a 50W cabinet fan, lower current means smaller breakers and less heat in the panel. The 2800 RPM operating point is deliberate: fast enough to move 268 m³/h through a compact 145mm impeller, yet slow enough that G6.3 balancing keeps this industrial axial fan at 46 dB(A) rather than 55–60 dB(A).
Space-constrained cooling is really an air-path problem. Inside a PLC cabinet, hot air rises; an intake louver near the bottom and an exhaust fan near the top create stack effect. This IP54 AC fan drops into that top-exhaust position with a frame fitting standard 145mm cutouts. Because the fan moves air parallel to the shaft, it needs little clearance behind it—unlike a centrifugal blower requiring volute depth. IP54 protects against conductive dust on workshop floors. For control-panel OEMs, compact depth, low noise, and three-phase reliability make this 145mm axial fan a drop-in standard.
For OEMs building control panels in volume, standardizing on this industrial axial fan eliminates the dual-SKU headache of stocking single-phase and three-phase variants. Because 380V is already ubiquitous on factory floors, 3-phase cabinet cooling fan drops into existing infrastructure without a transformer. The 50W draw keeps branch loads low, and 30,000-hour L10 bearing life means replacements rarely enter the spares chain. One part number fits every cabinet size; no lubrication or capacitor replacement needed. That is the commercial case for this industrial axial fan.

Q1: Why is this 145mm axial fan rated at 380V three-phase instead of 220V single-phase?
A: Three-phase winding runs more efficiently at the same shaft power, draws lower current, and has no starting capacitor to fail. In industrial plants where 380V is standard, 3-phase cabinet cooling fan drops into existing cabinet wiring. The 342–418V tolerance also handles voltage dips during machine starts.
Q2: Is 46 dB(A) really quiet enough for an office environment?
A: Yes. Typical office background is 40–50 dB(A), so a 46 dB(A) AC axial fan is barely perceptible behind a cabinet door. G6.3 balancing removes the tonal whine that makes small fans annoying even at low dB levels. For reception areas, this high-efficiency low-noise fan is one of the quietest in its frame size.
Q3: Can I add a filter guard to the intake of this 3-phase axial fan?
A: Yes, but note that a filter adds static resistance. This fan is rated for low-pressure cabinet applications; a coarse filter guard is fine, but a dense HE-grade filter will reduce airflow. For heavily dusty locations, pair the intake with a disposable pre-filter and verify that 268 m³/h still meets your heat-dissipation target.

Lobisong LBAA2D145S-5MNW-01 AC Axial Fan Ø145 mm — High-Efficiency Industrial Cooling Solution