lobisong-185mm-ac-axial-fan-industrial-axial-ventilation-fan-230v-stainless-steel-for-hvac-systems-cold-storage-air-purifiers, lobisong-185mm-ac-axial-fan-industrial-axial-ventilation-fan-230v-stainless-steel-for-hvac-systems-cold-storage-air-purifiers, /ac-cooling-fan
Inquiry
lobisong-185mm-ac-axial-fan-industrial-axial-ventilation-fan-230v-stainless-steel-for-hvac-systems-cold-storage-air-purifiers, lobisong-185mm-ac-axial-fan-industrial-axial-ventilation-fan-230v-stainless-steel-for-hvac-systems-cold-storage-air-purifiers, 
Inquiry

Lobisong 185mm AC Axial Fan, Industrial Axial Ventilation Fan, 230V, Stainless Steel, for HVAC Systems, Cold Storage, Air Purifiers

Lobisong 185mm AC Axial Fan is a robust industrial ventilation fan designed for continuous air movement in demanding environments.

Request a Quote
  • Overview

Overview

Product Description (Brief Summary)

Modern buildings demand ventilation that listens. The Lobisong 185mm AC axial fan is a UL/CE certified axial fan built around a BLEC external rotor motor, engineered to be a node in a building-management system rather than a dumb fixed-speed box. With optional 0-10V analog, PWM, or RS485 digital control, this smart ventilation fan modulates airflow to demand—lifting speeds when a sensor reads high CO₂, backing off at night. A multi-voltage platform (220V / 230V / 380V / 400V at 50 or 60 Hz) and ETL/UL/CE certifications let one model serve HVAC projects, cold rooms, air purifiers, and data rooms across multiple export markets.


image.pngimage.png
image.png 

Detailed Product Description & Technical Deep Dive

The BLEC external rotor motor is the heart of this industrial axial fan. Unlike a conventional motor where the rotor spins inside a stationary stator, an external rotor motor puts the rotating shell on the outside—directly carrying the impeller. That places the motor in the airstream for natural cooling, eliminating belts, couplings, and bearing overhang. The optional 0-10V / PWM / RS485 interface makes this an industrial 4.0 component: a BMS sends a setpoint, and this industrial axial fan adjusts speed to match the building's thermal load.


Multi-voltage architecture is the second differentiator. Instead of stocking separate SKUs for a 220V EU job, a 380V Chinese plant, and a 400V Middle East project, you specify one 185mm AC axial fan platform and select the winding at order. The 50/60Hz dual rating covers North American and European grids. Electronic protection layers—current limiting, over-temperature, over-current, locked-rotor, and soft-start—shield both motor and BMS from faults.
image.pngimage.png

Key Features & Benefits
  • BLEC external rotor motor: The motor shell sits in the airstream for natural cooling, delivering compact depth, high torque density, and long insulation life—core benefits of an external rotor motor fan.
  • 0-10V / PWM / RS485 smart control: Modulate airflow from a PLC, thermostat, or BMS, cutting energy use and noise at part load instead of running the fan flat-out.
  • Multi-voltage 50/60Hz platform: Select 220V, 230V, 380V, or 400V at 50 or 60 Hz, so one 185mm AC axial fan serves global grids and reduces SKU count.
  • Layered electronic protection: Current limiting, over-temperature, over-current, locked-rotor, and soft-start protect both the motor and your downstream control system.
  • IP44 / IP54 / IP55 rating options: Match protection to the environment—dry server rooms, splash-prone cold storage, or wash-down zones.
  • Global certification: ETL, UL, CE, RoHS, ISO9001, ISO14001, and BSCI support smooth market entry for USA and EU buyers sourcing this UL/CE certified axial fan.
Technical Specifications Table

Parameter

Value

Impeller diameter

185 mm

Rated voltage options

220V / 230V / 380V / 400V

Frequency

50 / 60 Hz

Motor type

BLEC external rotor motor

Speed control (optional)

0-10V / PWM / RS485

Operating temperature

-25 ~ +60 ℃

Operating humidity

0 ~ 85 % RH

Storage temperature

-25 ~ +70 ℃

Storage humidity

0 ~ 95 % RH

Applicable altitude

< 1000 m

Protection class options

IP44 / IP54 / IP55

Electronic protection

Current limiting, over-temperature, over-current, locked-rotor, soft start

Balance grade

G6.3 (JB/T 9101-1999)

Product standards

LVD EN60950-1; EMC EN61000-6-3, EN61000-4-2, EN61000-4-3

Certifications

ETL, UL, CE, RoHS, ISO9001, ISO14001, BSCI

Available materials

Standard frame; stainless steel option for corrosive/moisture environments

 

Engineering Advantages & Professional Analysis

The affinity laws explain why smart control matters. Airflow scales linearly with speed, static pressure with the square, and power with the cube. Running this industrial axial fan at 80% speed cuts power draw by roughly half. Without a 0-10V or PWM input, you cannot exploit that cube relationship. The BLEC external rotor motor responds cleanly across its speed range, and RS485 lets the controller read back operating hours and fault status. For a data center, that closed-loop operation turns this external rotor motor fan into a managed asset.


The external rotor architecture simplifies maintenance. Because the rotor carries blades directly, there is no belt to tension, no coupling to align, no overhung bearing to monitor. G6.3 balancing per JB/T 9101-1999 keeps vibration low across the speed range. When procurement standardizes on this industrial axial fan, spares carry across every project, and commissioning teams learn one mounting dimension and one control protocol. That standardization reduces engineering hours—the largest hidden cost in multi-site HVAC rollouts.

Target Applications
  • Smart building HVAC: Supply and exhaust air handling where the smart ventilation fan modulates via BMS to match occupancy and CO₂ levels.
  • Data center and telecom rooms: Reliable external rotor motor fan for server racks, control cabinets, and power electronics with continuous thermal management.
  • Air purifiers and filtration: Delivers steady axial airflow through filter media while speed control adapts to particulate load and room occupancy.
  • Cold storage and cold chain: Withstands -25°C pull-down and humid conditions, keeping refrigerated rooms ventilated and coils clear.
  • Controlled agriculture and grow rooms: 0-10V/PWM/RS485 modulates fresh-air exchange to maintain CO₂ and temperature balance in grow environments.
Commercial Value & B2B ROI

For OEMs and system integrators, this UL/CE certified axial fan raises total HVAC fan ROI across the project lifecycle. The multi-voltage platform standardizes one smart ventilation fan across export markets, cutting inventory carrying cost and spare-parts complexity. The 0-10V/PWM/RS485 control unlocks affinity-law energy savings—typically 30–50% reduction in fan energy at part load. Layered electronic protection boosts HVAC fan ROI, while ETL/UL/CE certification clears customs and spec-submission time. For smart-building integrators, RS485 read-back turns this external rotor motor fan into a maintainable asset rather than an ignored box.


image(e38a001587).pngimage.png

Frequently Asked Questions (FAQ)

Q1: How do I wire this smart ventilation fan to my building management system?

A: Use the optional 0-10V analog, PWM, or RS485 control interface. For 0-10V, connect a BMS analog output to the fan's control terminals; 0V maps to minimum speed and 10V to maximum. For RS485, daisy-chain the fan to your BMS bus and address it per the protocol sheet. A fault-output contact lets the BMS monitor lockout or over-temperature events.

Q2: Can one fan model really handle 220V through 400V grids?

A: Yes—this is a configurable multi-voltage platform. At order, you specify 220V, 230V, 380V, or 400V and 50 or 60 Hz. Each winding is optimized for its rated voltage; you do not reconfigure in the field. This simplifies global sourcing because engineering validates one physical design across regional variants.

Q3: Which IP rating should I choose for cold storage versus a server room?

A: For dry server rooms or filtered cabinets, IP44 suffices. For cold rooms and humid environments with condensation or wash-down, choose IP54 or IP55. IP55 also adds jet-spray resistance for coastal areas. The external rotor motor's natural cooling keeps operating temperature headroom in all three ratings.

image(c13e1c5178).pngimage(ca40dcda6d).png

Lobisong 185mm AC Axial Fan, Industrial Axial Ventilation Fan, 230V, Stainless Steel, for HVAC Systems, Cold Storage, Air Purifiers

Lobisong 185mm AC Axial Fan is a robust industrial ventilation fan designed for continuous air movement in demanding environments.

Request a Quote

Featured Products

lobisong 185mm ac axial fan industrial axial ventilation fan 230v stainless steel for hvac systems cold storage air purifiers-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Name
Company Name
Message
0/1000